• 제목/요약/키워드: Street Lamps

검색결과 41건 처리시간 0.024초

중앙관제시스템에 의한 LED 도로조명제어 (LED Street Light Lamp Control by Central Command System)

  • 조시형;박찬원
    • 산업기술연구
    • /
    • 제30권B호
    • /
    • pp.75-81
    • /
    • 2010
  • This paper presents the development of LED street light lamp which is controled by central command system. This system includes a lamp unit controller, data repeater and command repeater as well as the LED lamps. These devices enable the individual power control and partial on/off control of the LED lamps by the control repeater through full duplex communication line. Also, they have the ability to control the brightness and period of on/off timing by detecting the car's existence. As a result of this development, it is founded that the performances of the system have been satisfied to apply for the actual road test.

  • PDF

하이브리드 태양광 LED 가로등 시스템 연구 (A study on hybrid solar LED street light system)

  • 이동혁
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.20-25
    • /
    • 2022
  • In line with the rapid economic growth of many countries, fossil fuel energy sources are also rapidly depleting. Therefore, the price is also rising rapidly, so it is necessary to develop new and renewable energy sources such as hydropower, geothermal power, nuclear power, wind power and solar energy to replace fossil fuel energy in the future. In this study, development of rotating concentrator module system, development of rotating module control control system, development of lamp and charge control controller, configuration and prototype production of rotating concentrating solar LED street light system, efficiency of rotating concentrating solar LED street light, and power production. The research was conducted in the order of evaluation of comprehensive performance tests such as consumption and consumption. As a result, the developed high-efficiency rotation-concentrating hybrid solar LED street light module system has a 50% higher light-gathering efficiency than existing products by tracing sunlight by self-developing a rotation-collecting module on existing solar LED street lamps according to the characteristics of Korea's topography. and the power generation was improved by more than 40%.

변압기를 이용한 외장형 HID 램프용 공진형 이그니터 (External Resonant Ignitior for HID Lamps by Using the Transformer)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.9-16
    • /
    • 2014
  • The electronic ballast for HID lamps needs high ignition voltage which is consisted of high voltage pulse ignitor. However, In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. However, the resonant circuit which is consisted of LC occurs over current, so the capacity of the ignitor increases. The capacity of the ignitor can be reduced by using the transformer. In this case, the capacitor for resonance is installed to the secondary of the transformer, and the capacitor needs high withstanding voltage. Therefore, it needs to do the research on a resonant ignition to reduce the voltage over the resonant capacitor by dividing the secondary of the transformer.

비대칭 배광을 갖는 LED 가로등 2차렌즈 설계 (Secondary Optical Design of LED lens with Asymmetric Light Distribution for street)

  • 김성현;신익태;양종경;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.162-162
    • /
    • 2010
  • In this study, optical analysis for 100W LED safety street lighting was conducted. Experimental research on such single LED was the first undertaken. simulation modeling based on optical properties of single LED has compared single LED product also designed 100W simulation modeling has compared average road illuminance with Korean Industrial Standards for LED safety street lighting(KS C7658:2009). 100W safety street lighting (model: CE180-ST-OS) designed by simulation has been also compared between product and 100W simulation modeling, and error rates have showed average 5.6[%]. Designed 100W LED safety street lighting base on simulation modeling was proven by comparison experiments. Through the simulations and the corresponding analysis, it was found that the tested 100W LED safety street lamp had reasonable performance. Design method for LED safety Street lamps have been summarized, based on the optical analysis.

  • PDF

가변색온도 가로등 구현을 위한 혼색LED의 조명특성 (A Light Characteristics of Mixed-Color LED for the Variable Color Temperature Street Light)

  • 정병호;이강연;최연옥;김대곤;김남오;민완기
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.142-147
    • /
    • 2009
  • Conventional HP(high pressure) sodium or Metal-halide lamps have a life span of around one year requiring at least annual replacement and maintenance. High Power LED lights require no regular maintenance further increasing savings on replacement bulbs, access equipment and labour costs. New installations benefit from a substantial reduction in the cost of expensive heavy duty cable required for sodium lighting. Especially, LED light can achieve variable color temperature, high functional performance in the field of street light. There are two main method to achieve variable color temperature function of the street light. one method is using RGB multi-chip LED, the other is using Orange-White LED method. In this paper, it was compare RGB Multi-chip LED with white-orange LED for there characteristics performance.

2-단계 HID 램프용 전자식 안정기의 디지털 제어 (Digital Control of Two-Stage Electronic ballast for HID Lamps)

  • 이우철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.229-230
    • /
    • 2013
  • The conventional Three-Stage electronic ballast is stable, but Two-Stage electronic ballast has been researching because of efficiency. Three-Stage electronic ballast is consisted of PFC circuit, buck converter, and inverter circuit, but Two-stage is consisted of PFC circuit, Buck-Inverter full bridge circuit. The Buck-Inverter full bridge inverter consists of two half bridge inverters for low frequency switching, and high frequency switching. In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. Therefore, in the Two-Stage electronic ballast which has the resonant tank for ignition, the transient resonant current because of low frequency changing is analyzed, the novel algorithm is proposed to resuce the transient current.

  • PDF

HID 램프용 Two-Stage 전자식 안정기의 과도 전류 제어 (Transient Current Control of Two-Stage Electronics Ballast for HID Lamps)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-8
    • /
    • 2014
  • The conventional Three-Stage electronic ballast is stable, but Two-Stage electronic ballast has been researching because of efficiency. Three-Stage electronic ballast is consisted of PFC circuit, buck converter, and inverter circuit, but Two-stage is consisted of PFC circuit, Buck-Inverter full bridge circuit. The Buck-Inverter full bridge inverter consists of two half bridge inverters for low frequency switching, and high frequency switching. In the case of street lamp it is far from a lamp to a ballast, the conventional pulsed high voltage ignitor can not turn on the HID lamps because of reduction of ignition voltage. Therefore, it needs to do the research on a resonant ignition to turn on the HID lamps. Therefore, in the Two-Stage electronic ballast which has the resonant tank for ignition, the transient resonant current because of low frequency changing is analyzed, the novel algorithm is proposed to resuce the transient current.

저 가격형 Zigbee 통신 네트워크 기반 HID 가로등의 원격 제어 및 감시 시스템 개발 (Development of Remote Control and Monitoring System for HID Street-lamp Based on Low Cost Zigbee Communication Network)

  • 정완섭;김양배;손진근
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.69-73
    • /
    • 2014
  • In this paper, remote control and surveillance monitoring system of HID street-lamp using low-cost type of Zigbee communication module was developed. A plurality of capacitors with different capacity are attached to magnetic ballast for HID lamps. Changes in the amount of illumination can be adjusted by the changes in capacity so that the electric energy can be reduced. In Zigbee communication module, a ATmega128L microprocessor is used and in main CPU, ARM9 Core is used to construct a low-cost smart system. In surveillance monitoring systems, the system was configured to remote monitoring of presence of error in the lamp abnormalities, the status of leakage current and abnormalities of ballasts and capacitors and the validity of the proposed empirical experiment was confirmed.

USN 기반의 에너지 및 안전성 효율적인 LED 가로등 제어 시스템 (Energy and Safety Efficient LED Street-light Control System Based on Ubiquitous Sensor Network)

  • 조면균;김식;양우석
    • 대한임베디드공학회논문지
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 2011
  • LEDs are becoming the most suitable candidate replacing traditional fluorescent street-light lamps because of its energy efficiency and high brightness. Furthermore, most countries are urging to pursue energy savings in conjunction with IT and sensor network. In order to conserve energy of LED lamp and ensure the safety of pedestrian, we propose a new smart control method for LED light system based on USN using compound sensors, such as illuminance, motion, temperature and humidity sensor. An elaborate simulation shows that the proposed system with a smart control based switching can reduce the energy by 40%, compared to the previous street-light system with a fixed time based switching.

Study on Simulation Design of Light Emitting Diode Luminaires for 100 W Safety Street Lighting

  • Shin, Ik-Tae;Lee, Se-Il;Yang, Jong-Kyoung;Park, Dae-Hee;Lee, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권3호
    • /
    • pp.138-144
    • /
    • 2010
  • Optical analysis is necessary to optimize light emitting diode (LED) safety street lighting. In this study, optical analysis was conducted for 100 W LED safety street lighting. Experimental research on such a single LED was the first undertaken. Simulation modeling based on the optical properties of the single LED has compared between average road illuminances and has them analyzed with Korean Industrial Standards for LED safety street lighting (KS C7658:2009). The simulation results demonstrated that the illumination performance (average road illuminance) was 75.3 lx at a height of 4 m and an area of $32\;m^2$, 45.25 lx at a height of 5 m and an area of $72\;m^2$, and 30.05 lx at a height of 6 m and an area of $128\;m^2$. 100 W safety street lighting (model CE180-ST-OS) designed by simulation was also compared between product and 100 W simulation modeling, and error rates averaged 5.6%. The 100 W LED safety street lighting base designed in simulation modeling was proven by comparison experiments. Through the simulations and the corresponding analysis, it was found that the tested 100 W LED safety street lamp had reasonable performance. The design method for LED safety street lamps has been summarized based on the optical analysis.