• Title/Summary/Keyword: Stream and effluents

Search Result 47, Processing Time 0.026 seconds

Nitrate Removal Rate in Reed Wetland Cells of a Pond-Wetland Stream Water Treatment System (하천수정화 연못-습지 시스템의 갈대 습지셀 초기 질산성질소 제거)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.4
    • /
    • pp.274-278
    • /
    • 2002
  • Nitrate removal rate in three wetland cells was examined. The acreage of each cell was 150 $m^2$. They were a part of a stream water treatment demonstration system which was composed of two ponds and six wetland cells. Earth works far the pond-wetland system were finished from April 2000 to May 2000 and reeds were planted in the three cells in May 2001. Waters of Sinyang Stream flowing into Kohung Esturiane Lake located southern coastal area of Korean Peninsula were pumped into a primary pont Effluents from a secondary pond were funneled into the three cells. Volumes and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged 20 $m^3/d$ and 19.3 $m^3/d$, respectively. Hydraulic retention time was 1.5 days. Average influent and effluent nitrate concentration was 2.30 mg/L, 1.75 mg/L, respectively. Nitrate removal rate in the three cells averaged 80.9 $mg/m^2/day$. Seasonal changes of nitrate retention rates were closely related to those of wetland temperatures. Full growth of reeds within a few years can develope litter-soil substrates beneficial to the denitrification of nitrate, which may lead to increases of the nitrate retention rates.

The Whole Effluent Toxicity Tests of Wastewater Discharged from Various Wastewater Treatment Plants and Their Impact Analyses on Biological Component (폐수처리장의 전 방류수 독성 평가 및 방류수 배출하천의 생지표도 영향분석)

  • Ra, Jin-Sung;Kim, Sang-Don;An, Kwang-Guk;Chang, Nam-Ik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.353-361
    • /
    • 2005
  • In this study, we performed whole effluent toxicity(WET) test and compared the biological component analyses tests for some streams into which wastewater treatment plant effluents are discharged. The test procedures for the WET test and the biological component analysis were conducted according to U.S. EPA guidelines and the Ohio EPA wading method. The WET tests based on the test species of D. manga and S. capricornutum All treatment plants showed a S. capricornutum toxicity, and at 7 sites, except A and J, we could observe a D. magna toxicity. The highest toxicity was observed at site D and this were followed by E and F. The biological component analyses applied to the effluent discharged stream. We found that total species were low at sites C1, D1 and J1 and the low number of total individuals were observed at sites A1, C1, E1, H1, and J1 compared to the controls and other sites. The species richness was low at sites A1, B1, C1, D1, and J1. The species change was evident at site D(D1) and the tolerant species was predominant. The biological analyses and WET tests suggested that the effluents resulted in massive ecosystem impact.

Problems of lake water management in Korea (한국의 호수 수질관리의 문제점)

  • 김범철;전만식;김윤희
    • Proceedings of the Korean Society of Environment and Ecology Conference
    • /
    • 2003.10a
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF

Evaluation of Nutrients Removal Efficiency in Effluents of Sewage and Wastewater using Microalgae (미세조류를 이용한 오·폐수 영양염류 제거효율 평가)

  • Kim, Sook-chan;Kim, Han-soon
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.2
    • /
    • pp.187-194
    • /
    • 2017
  • This study was intended to evaluate the removal efficiency of nutrients in effluents of wastewater using microalgae. Microalgae used in the culture experiment collected in stream and reservoir located in Gyeongsangbuk-do. Dominant species in prior-culture tank were Monoraphidium contortum, Scenedesmus acutus, Coelastrum microporum and Chlorella sp. Dominant species in synthetic wastewater culture under the 4000 Lux and 8000 Lux were Chlorella sp. and Scenedesmus obliquus. The removal efficiency of $NO_3-N$ under the 4000 Lux and 8000 Lux were 27.2%~88.1% and 63.0%~83.6% respectively. The removal efficiency of $PO_4-P$ under the 4000 Lux and 8000 Lux showed above 93%. Removal efficiency of nutrients of $1.0{\times}10^6cells\;mL^{-1}$ inoculation concentration was more higher than that of nutrients of $1.0{\times}10^5cells\;mL^{-1}$ and $1.0{\times}10^7cells\;mL^{-1}$ inoculation concentration. Microalgae cultured in synthetic wastewater removed 94.9% of TN and 90.0% of TP. The removal rate of TN and TP in synthetic wastewater were $1.961mg\;L^{-1}\;day^{-1}$ and $0.200mg\;L^{-1}\;day^{-1}$ respectively. Nutrient removal efficiency of microalgae according to kinds of wastewater showed the highest in the private sewage.

Assessment of Contamination and Sources Identification of Heavy Metals in Stream Water and Sediments around Industrial Complex (산업단지 유역 하천수와 퇴적물 내 중금속 오염도 평가 및 기원 추적 연구)

  • Jeong, Hyeryeong;Lee, Jihyun;Choi, Jin-Young;Kim, Kyung-Tae;Kim, Eun-Soo;Ra, Kongtae
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.3
    • /
    • pp.179-191
    • /
    • 2019
  • Heavy metals in stream water and sediments around industrial complex were studied in order to assess the contamination and to identify the potential source of metals. High variability has been observed for both dissolved and particulate phases in stream water with coefficient of variation (CV) ranging from 1.3 to 2.8. The highest metal concentrations in both phases were observed in Gunja for Ni and Cu, in Jungwang for Zn and Pb and in Shiheung for Cd, respectively. These results indicate that the different metal sources could be existing. The concentrations of the heavy metals in sediments decreased in the order of Cu>Zn>Pb>Cr>Ni>As>Cd>Hg, with mean of 2,549, 1,742, 808, 539, 163, 17.1, 5.8, $0.07mg\;kg^{-1}$, respectively. Mean of metal concentrations(except for As) in sediments showed the highest values at Shiheung stream comparing with other streams. In sediments, the percent exceedance of class II grade that metal may potentially harmful impact on benthic organism for Cr, Ni, Cu, Zn, Cd, Pb was about 57%, 62%, 84%, 60%, 68%, 81% for all stream sediments, respectively. Sediments were classified as heavily to extremely polluted for Cu and Cd, heavily polluted for Zn and Pb, based on the calculation of Igeo value. About 59% and 35% of sediments were in the categories of "poor" and "very poor" pollution status for heavy metals. Given the high metal concentrations, industrial wastes and effluents, having high concentrations of most metals originated from the manufacture and use of metal products in this region, might be discharged into the stream through sewer outlet. The streams receive significant amounts of industrial waste from the industrial facilities which is characterized by light industrial complexes of approximately 17,000 facilities. Thus, the transport of metal loads through streams is an important pathway for metal pollution in Shihwa Lake.

Assessment of Water Quality in Pyeongtaek Reservoir and Its Main Tributaries (평택호와 유역 주요 하천의 수환경 및 오염도 평가)

  • Hwang, Soon-Jin;Cho, Kyung-Je;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.1 s.102
    • /
    • pp.38-47
    • /
    • 2003
  • The water quality of the Pyeongtaek Reservoir and its main streams has been eval uated far water pollution state in March, June, September and December,2000. The following are the findings: $NH_4$ accounts for the majority of TN in the inflow streams. In the reservoir, TN and $NH_4$ are the more present in the winter season and less in the summer season, with $1.6{\sim}2.4$ times of $NO_3$ and $5.3{\sim}11.4$ times of $NO_2$ found in December and June compared with other seasons. The concentration of each component is different between streams: $NH_4$ among inorganic nitrogen has the highest concentration in the upstream, and $NO_3$ is more prevalent in the downstream. SRP accounts for $25{\sim}69%$ of TP in the stream. Unlike N component, P component in the reservoir rapidly decreases from upstream toward downstream, except in the summer. Average SRSi slightly increases in the fall, i.e., immediately after rainfall. In the streams, the average concentration of chlorophyll-a ranges from 9 to $33{\mu}g/l$, and is relatively high in the downstream. In contrast, in the reservoir, it is the highest in the upstream where $NH_4$ and SRP are frequently found. In particular, diatom and cryptomonad algae are bloomed in March, and blue-green algae in September; their maximum values are $108{\mu}g/l$ and $130{\mu}g/l$, respectively. Considering the concentration of N and P nutrients, pollution loads can affect the Pyeongtaek Reservoir in the downstream in this order: Ansong Stream

Priority Assessment for Remediation of Heavy Metals Closed/Abandoned Mine Areas Using Pollution Indexes

  • Kim Hee-Joung;Yang Jae-E.;Park Byung-Kil;Kong Sung-Ho;Lee Jai-Young;Jun Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.183-193
    • /
    • 2006
  • Several metalliferous and coal mines, including Seojin and Okdong located at the Kangwon province, were abandoned or closed since 1989 due to the mining industry promotion policy and thus disposed an enormous amount of mining wastes without a proper treatment facilities, resulting in water and soil pollution in the downstream areas. However, no quantitative assessment was made on soil and water pollution by the transport of mining wastes such as acid mine drainage, mine tailing, and rocky waste. In this research, total and fractional concentrations of heavy metals in mining wastes were analyzed and accordingly the degree of water and soil pollutions in the stream area were quantitatively assessed employing the several pollution indices. Concentrations of Ni, Cd, and Pb in soils near the abandoned coal mine areas were 1,240.0, 25.0 and 1,093.0 mg/kg, respectively, and these concentrations were higher than those in soils near the closed metalliferous mine areas. Also Cu concentrations in soils near the tailing dams were about 1967 mg/kg, which is considered as very polluted level. Results demonstrated that soil at the abandoned mine areas were highly contaminated by AMO, tailing, and effluents of the mining wastes. Therefore, a prompt countermeasure on the mining waste treatment and remediation of the codntaminated water and soil should be made to the abandoned or closed metalliferous and coal mines located at the abandoned mine area.

  • PDF

Analysis of the Phosphorus Contribution Rate by the Environment Fundamental Facilities Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 환경기초시설의 인 기여도 분석)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Yang, Heejeong;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1016-1027
    • /
    • 2010
  • The phosphorus contribution rate on water quality of North and South-Han River, and Gyungan-cheon by effluents from environmental fundamental facilities located in upstream basin of Paldang Lake were analyzed. QUALKO2 model was selected for the analysis of contrubution rate, and was constructed considering the location of the main point sources and all facilities in study area. The pollutant loading rates and arrival rates for each unit-watershed in study area were calculated for model operation. For the calibration and verification of model, 2006 water quality dataset from Ministry of Environment and the effluent loadings of the environmental fundamental facilities were used. Reliability Index (RI) method was used to estimate the validity of the results of calibration and verification. The phosphorous contribution rate(%) for each environmental fundamental facility were analyzed by excepting the effluent loading of the facility. The contribution rate was analyzed for each facility, facility groups separated by each main river and each unit-watershed. The main results of analysis for each facility are as follows; (i) the phosphorous contribution of B1 facility is 50%, which is the highest phosphorous contribution rate among those of nine facilities in the North-Han River Basin; (ii) the highest phosphorous contribution is 55.6% from J facility among eight facilities in the Gyungan Stream Basin; (iii) 40% from E treatment facility is the highest among those of twenty eight facilities in the South-Han River Basin.

Effects of Gumi City Sewage Treatment Effluent in the Downstream Nutrient Matter: Comparison of Daily Loading (구미시 하수처리 방류수가 하류 하천 영양염류에 미치는 영향: 부하량 비교)

  • Seong, Jin-Uk;Lee, Sang-Pal;Lee, Jae-Kyun;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1643-1650
    • /
    • 2013
  • This study investigated water quality of effluents and stream from the sewage treatment plants located at Gumi Complex 4, Gumi, and Wonpyeong in Gumi. Downstream region was found to increase the concentration of nutrients for sewage treatment plant effluent. Both phosphorus and nitrogen were accounted most as soluble form. In particular, the high ratio of dissolved effluent of sewage treatment plants were investigated. In the streams, Phosphorus concentration was high during rainy season and nitrogen concentration was high in the dry season. Sewage treatment plant effluent was relatively less microbial activity and nutrient concentrations were higher in the winter. TN/TP ratio was the highest in the upstream region and the lowest in the sewage treatment plant effluent. The effect of the nutrient matter from a discharge of a sewage treatment plant on rivers varied depending on the size of the river and the treatment plant. However, the influence of the concentration was greater than that of flowrate. Sewage treatment plant effluent loads phosphorus, nitrogen accounted for 8% and 6% respectively at the point N3 of the Nakdong river.

Evaluation of Runoff Loads and Computing of Contribute ratio by First Flush Stormwater from Cheongyang-Hongseong Road (청양-홍성간 도로에서의 초기강우에 의한 유출부하량 평가 및 기여율 산정)

  • Lee, Chun-Won;Kang, Seon-Hong;Choi, I-Song;An, Tae-Ung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.407-417
    • /
    • 2011
  • Nowadays, the high land use, mainly used for urbanization, is affecting runoff loads of non-point pollutants to increase. According to this fact, increasing runoff loads seems like to appear that it contributes to high ratio of pollution loads in the whole the pollution loads and that this non-point source is the main cause of water becoming worse quality. Especially, concentrated pollutants on the impermeable roads run off to the public water bodies. Also the coefficient of runoff from roads is high with a fast velocity of runoff, which ends up with consequence that a lot of pollutants runoff happens when it is raining. Therefore it is very important project to evaluate the quantity of pollutant loads. In this study, I computed the pollutant loadings depending on time and rainfall to analyze characteristics of runoff while first flush storm water and evaluated the runoff time while first flush storm water and rainfall based on the change in curves on the graph. I also computed contribution ratio to identify its impact on water quality of stream. I realized that the management and treatment of first flush storm water effluents is very important for the management of road's non-point source pollutants because runoff loads of non-point source pollution are over the 80% of whole loads of stream. Also according to the evaluation of runoff loads of first flush storm water for SS, run off time was shown under the 30 minute and rainfall was shown under the 5mm which is less than 20% of whole rainfall. These are under 5mm which is regarded amount of first flush storm water by the Ministry of Environment and it is judged to be because run off by rainfall is very fast on impermeable roads. Also, run off time and rainfall of BOD is higher than SS. Therefore I realized that the management of non-point source should be managed and done differently depending on each material. Finally, the contribution ratio of pollutants loads by rainfall-runoff was shown SS 12.7%, BOD 12.7%, COD 15.9%, T-N 4.9%, T-P 8.9%, however, the pollutants loads flowing into the steam was shown 4.4%. This represents that the concentration of non-point pollutants is relatively higher and we should find the methodical management and should be concerned about non-point source for improvement on water quality of streams.