• Title/Summary/Keyword: Streak camera

Search Result 17, Processing Time 0.027 seconds

Three-Dimensional Measurement of Moving Surface Using Circular Dynamic Stereo

  • Lee, Man-Hyung;Hong, Suh-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.101.3-101
    • /
    • 2001
  • By setting a refractor with a certain angle against the optical axis of the CCD camera lens, the image of a measuring point recorded on the image plane is displaced by the corresponding amounts related to the distance between the camera and the measuring point. When the refractor that keeps the angle against the optical axis is rotated physically at high speed during the exposure of the camera, the image of a measuring point draws an annular streak. Since the size of the annular streak is inversely proportional to the distance between the camera and the measuring point, the 3D position of the measuring point can be obtained by processing the streak. In this paper, for one of the applications of our system, the measurement of a moving surface is introduced. In order to measure the moving surface, multi laser spots are projected on the surface of object. Each position of ...

  • PDF

A Streak Camera Study of Amplified Spontaneous Emission in Polyfluorene Thin Film

  • Shin, Hee-Won;Kim, Yong-Rok
    • Rapid Communication in Photoscience
    • /
    • v.4 no.4
    • /
    • pp.76-78
    • /
    • 2015
  • We report on the photoluminescence (PL) properties of poly[2,7-(9-9-dioctylfluorene)] (PF) thin film under strong optical pumping using a streak camera system. When the excitation energy density increases above $72{\mu}J{\cdot}cm^{-2}$, the emission spectrum becomes narrower and PL decay curve comes to be faster simultaneously. These behaviors are clear evidence of Amplified Spontaneous Emission (ASE) due to a waveguided Stimulated Emission in slab structure of thin film. ASE threshold of $72{\mu}J{\cdot}cm^{-2}$ is comparable with previous reports and PF is attractive as a gain medium for plastic lasers.

Picosecond Absorption Kinetic Spectrometer with a Laser and a Streak Camera

  • Jang, Du-Jeon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.172-176
    • /
    • 1990
  • A high resolution picosecond absorption kinetic spectrometer utilizing dye emission and a streak camera is presented and compared with other methods of picosecond transient absorption measurements. Typical transient absorption and bleach recovery kinetics measured with this spectrometer are shown. Single wavelength transient absorption or ground state bleach recovery kinetics are determined on the basis of a single laser shot, so that the samples are relatively free frm decomposition by irradiation. Excellent kinetics may be obtained from the near UV to the near IR and are not subject to interference from luminescence of samples. The sensitivity of this spectrometer is very high and it is reasonably easy and convenient to set up and use.

  • PDF

Visualization of Underwater Sympathetic Detonation of High Explosives

  • Itoh, Shigeru;Hamada, Toru;Murata, Kenji;Kato, Yukio
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1822-1828
    • /
    • 2001
  • The experiment for the sympathetic detonation (Sudo et al., 1951) (Fukuyama et al., 1958) in water was conducted. Composition B (RDX: 64%, TNT: 36%, Detonation velocity: 7900m/s) was used for both donor (the thickness was 50mm, and the diameter was 31mm) and receptor charges. The distance between the donor and the receptor, and the thickness (5, 7.5, 10mm) of the receptor were varied in the experiments. In order to investigate the basic characteristics of the underwater sympathetic detonation of high explosive, the sympathetic detonation phenomena were visualized by a high-speed camera (HADLAND PHOTONICS, IMACON790) in forms of streak and framing photographs. The 200ns/mm streak velocity was 2㎲. Manganin gauges (KYOWA Electronic INSTRUMENTS CO. SKF-21725) were used for the pressure measurements. The gauges were set under the receptor. The pressures during the complete and incomplete explosions were measured.

  • PDF

Three-dimensional measurement of object surface and moving particles using at TV camera

  • Kawasue, Kikuhito;Iwamoto, Isamu;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1302-1305
    • /
    • 1997
  • A new approach to the three-dimensional measurement of the object surface and moving particles is introduced. A single TV camera with an apparatus to add the circular bias to the image enables us to record the three-dimensional information of measuring points as streaks on a single image. Every shaped of the streak on the image plane is related to the position of the measuring point. the information is extracted form the image using an image processign technique.

  • PDF

Rain Detection and Removal Algorithm using Motion-Compensated Non-local Means Filter for Video Sequences (동영상을 위한 움직임 보상 기반 Non-Local Means 필터를 이용한 우적 검출 및 제거 알고리즘)

  • Seo, Seung Ji;Song, Byung Cheol
    • Journal of Broadcast Engineering
    • /
    • v.20 no.1
    • /
    • pp.153-163
    • /
    • 2015
  • This paper proposes a rain detection and removal algorithm that is robust against camera motion in video sequences. In detection part, the proposed algorithm initially detects possible rain streaks by using intensity properties and spatial properties. Then, the rain streak candidates are selected based on Gaussian distribution model. In removal part, a non-rain block matching algorithm is performed between adjacent frames to find similar blocks to the block that has rain pixels. If the similar blocks to the block are obtained, the rain region of the block is reconstructed by non-local means (NLM) filter using the similar neighbors. Experimental results show that the proposed algorithm outperforms the previous works in terms of subjective visual quality of de-rained video sequences.

The investigation of Diesel Spray Combustion in DME HCCI (DME 예혼합기를 분위기로 하는 디젤 분무의 연소에 관한 연구)

  • Lim, Ock-Taeck;Iida, Norimasa
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3329-3334
    • /
    • 2007
  • The purpose of the research is to investigate of diesel spray combustion for simultaneously reduce way NOx and PM. The pressure diesel injection were done into intermediates that are generated by very lean DME HCCI combustion using a RCM. The concentration of intermediate could not be directly measured; we estimated it by CHEMKIN calculation. DME HCCI characteristic is surveyed. Validations of the CHEMKIN calculation were confirmed pressure rise of an experiment and pressure rise of a calculation. Using a framing streak camera captured two dimensional spontaneous luminescence images from chemical species at low temperature reaction(LTR) and high temperature reaction (HTR). Also, the combustion events were observed by high-speed direct photography, the ignition and combustion were analyzed by the combustion chamber pressure profiles.

  • PDF

An experimental study on mechanism for the disintegration of liquid film surface waves by a parallel air flow (평행공기류에 의한 액막류 표면파의 분열기구에 관한 실험적 연구)

  • 이규영;양옥용
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.81-90
    • /
    • 1992
  • This paper deals with an experimental study on the initial condition of liquid film surface waves disintegration and investigation on the behavior of liquid film surface waves formed by the high speed air flow on the solid plane surface. The authors conducted the qualitative and quantitative study to in vestigate the liquid film flow phenomena, the liquid film disintegration mechanism, and droplet formation process with breaking the liquid film surface wave. The newly devised transparent rectangular test section which has semi-two-dimensional flow at the center of the bottom was introduced to perform the experimental study, and it can generate the uniform thickness liquid film at the bottom. The strobo streak camera was used to obtain the instantaneously transformed photographs. The electronic measuring device was also used to measure the liquid film thickness variation in order to perform the easy and effective analysis of complex flow phenomena in the air-water cocurrent flow.

  • PDF

F-Center Excitation Energy Transfer to CN$^-$ vibrational Levels in CsCl

  • Jang, Du-Jeon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.07a
    • /
    • pp.94-100
    • /
    • 1990
  • The rapid quenching dynamics of the F-center excitation by CN- defects in CsCl crystals were investigated by monitoring the ground state bleach recovery kinetics of F-centers, using a picosecond streak camera absorption spectrometer. The F-centers in CN- doped quenched samples show two bleach recovery components. Optical aggregation converts the slow component to the fast component. The slow one is due to the normal relaxation of the F*-centers as found in CN_ free crystals. The fast one is due to the energy transfer of the F-center electronic excitation to the vibrational energy levels of CN_ molecualr defects. The energy transfer occurs only in the F-center-CN_ defect pairs, FH(CN_)-centers.

  • PDF

The Investigation of Diesel Spray Combustion in DME HCCI Combustion (DME 예혼합 자기착화 연소중의 디젤분무연소에 관한 연구)

  • Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.241-248
    • /
    • 2008
  • The purpose of the research is to investigate of diesel spray combustion for simultaneously reduction way of NOx and PM. The diesel injection were done into intermediates that are generated by very lean DME HCCI combustion using a RCM. The concentration of intermediate could not be directly measured, so we estimated it by CHEMKIN calculation. Two dimensional spontaneous luminescence images which are created by chemical species reaction at low temperature reaction (LTR) and high temperature reaction (HTR) are captured by using a framing streak camera. Also, combustion events were observed by high-speed direct photography. The ignition and combustion events were analyzed by pressure profiles and the KL values and flame temperatures were analyzed by the two-color method.