• 제목/요약/키워드: Strain amplitude

검색결과 296건 처리시간 0.024초

핵연료 프레팅 마멸에서 마멸면적을 이용한 스프링 형상 영향 평가 (Evaluation of spring shape effect on the nuclear fuel fretting using worn area)

  • 이영호;김형규;정연호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.313-323
    • /
    • 2003
  • The sliding wear behaviors of Zircaloy-4 nuclear fuel rod were investigated using two support springs with convex and concave shapes in room temperature air and water. The main focus is to compare the wear behavior of various test variables such as slip amplitude, environment, contact contours with different spring shape and a number of cycles. The results indicated that wear volume and maximum wear depth increased with slip amplitude in both air and water, but their trends tended to change according to the spring shapes and test environments. In air condition, the wear volume was controlled by wear debris behavior generated on worn surface. As a result, final wear volume and maximum wear depth decreased if a ratio of protruded wear volume to worn area $(D_p)$ would be saturated to specific value. This is because wear particle layer could accommodate large strain by accumulating and transforming wear particle layer. However, in water condition, metal-to metal contact was more dominant and wear volume was greatly affected by changed mechanical behavior between contact surfaces since wear debris should be generated after repeated plastic deformation and fracture. After wear test, worn surfaces were examined using optical microscope and SEM and details of wear mechanism were discussed using a ratio of wear volume to worn area $(D_e)$ at each test condition.

  • PDF

Field monitoring of the train-induced hanger vibration in a high-speed railway steel arch bridge

  • Ding, Youliang;An, Yonghui;Wang, Chao
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.1107-1127
    • /
    • 2016
  • Studies on dynamic characteristics of the hanger vibration using field monitoring data are important for the design and evaluation of high-speed railway truss arch bridges. This paper presents an analysis of the hanger's dynamic displacement responses based on field monitoring of Dashengguan Yangtze River Bridge, which is a high-speed railway truss arch bridge with the longest span throughout the world. The three vibration parameters, i.e., dynamic displacement amplitude, dynamic load factor and vibration amplitude, are selected to investigate the hanger's vibration characteristics in each railway load case including the probability statistical characteristics and coupled vibration characteristics. The influences of carriageway and carriage number on the hanger's vibration characteristics are further investigated. The results indicate that: (1) All the eight railway load cases can be successfully identified according to the relationship of responses from strain sensors and accelerometers in the structural health monitoring system. (2) The hanger's three vibration parameters in each load case in the longitudinal and transverse directions have obvious probabilistic characteristics. However, they fall into different distribution functions. (3) There is good correlation between the hanger's longitudinal/transverse dynamic displacement and the main girder's transverse dynamic displacement in each load case, and their relationships are shown in the hysteresis curves. (4) Influences of the carriageway and carriage number on the hanger's three parameters are different in both longitudinal and transverse directions; while the influence on any of the three parameters presents an obvious statistical trend. The present paper lays a good foundation for the further analysis of train-induced hanger vibration and control.

SPR 접합법을 이용한 Al-5052 인장-전단 시험편의 피로강도 (Fatigue Strength of Al-5052 Tensile-Shear Specimens using a SPR Joining Method)

  • 이만석;김택영;강세형;김호경
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.9-14
    • /
    • 2014
  • Self-piercing riveting(SPR) is a mechanical fastening technique which is put pressure on the rivet for joining the sheets. Unlike a spot welding, SPR joining does not make the harmful gas and $CO_2$ and needs less energy consumption. In this study, static and fatigue tests were conducted using tensile-shear specimens with Al-5052 plates for evaluation of fatigue strength of the SPR joints. During SPR joining process for the specimen, using the current sheet thickness and a rivet, the optimal applied punching force was found to be 21 kN. And, the maximum static strength of the specimen produced at the optimal punching force was 3430 N. During the fatigue tests for the specimens, interface failure mode occurred on the top substrate close to the rivet head in the most high-loading range region, but on the bottom substrate close to the rivet tail in the low -loading range region. There was a relationship between applied load amplitude $P_{amp}$ and lifetime of cycle N for the tensile-shear, $P_{amp}=3395.5{\times}N^{-0.078}$. Using the stress-strain curve of the Al-5052 from tensile test, the simulations for fatigue specimens have been carried out using the implicit finite element code ABAQUS. The relation between von-Mises equivalent stress amplitude and number of cycles was found to be ${\sigma}_{eq}=514.7{\times}N^{-0.033}$.

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

The efficient data-driven solution to nonlinear continuum thermo-mechanics behavior of structural concrete panel reinforced by nanocomposites: Development of building construction in engineering

  • Hengbin Zheng;Wenjun Dai;Zeyu Wang;Adham E. Ragab
    • Advances in nano research
    • /
    • 제16권3호
    • /
    • pp.231-249
    • /
    • 2024
  • When the amplitude of the vibrations is equivalent to that clearance, the vibrations for small amplitudes will really be significantly nonlinear. Nonlinearities will not be significant for amplitudes that are rather modest. Finally, nonlinearities will become crucial once again for big amplitudes. Therefore, the concrete panel system may experience a big amplitude in this work as a result of the high temperature. Based on the 3D modeling of the shell theory, the current work shows the influences of the von Kármán strain-displacement kinematic nonlinearity on the constitutive laws of the structure. The system's governing Equations in the nonlinear form are solved using Kronecker and Hadamard products, the discretization of Equations on the space domain, and Duffing-type Equations. Thermo-elasticity Equations. are used to represent the system's temperature. The harmonic solution technique for the displacement domain and the multiple-scale approach for the time domain are both covered in the section on solution procedures for solving nonlinear Equations. An effective data-driven solution is often utilized to predict how different systems would behave. The number of hidden layers and the learning rate are two hyperparameters for the network that are often chosen manually when required. Additionally, the data-driven method is offered for addressing the nonlinear vibration issue in order to reduce the computing cost of the current study. The conclusions of the present study may be validated by contrasting them with those of data-driven solutions and other published articles. The findings show that certain physical and geometrical characteristics have a significant effect on the existing concrete panel structure's susceptibility to temperature change and GPL weight fraction. For building construction industries, several useful recommendations for improving the thermo-mechanics' behavior of structural concrete panels are presented.

FURA 코드 개발과 부하 추종 운전에 대한 적용 (Development of FURA Code and Application for Load Follow Operation)

  • Park, Young-Seob;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.88-104
    • /
    • 1988
  • 이차원의 유한요소법을 이용하여 axisymmetric R-$\theta$system으로 나누어서 정상과 부하추종 운전시에 핵연료 페렛트와 피복관의 열역학적 거동을 분석하기 위해서 FURA전산코드를 개발하였다. 온도분포와 내부압력을 정확히 계산하기 위해서 페렛트와 피복관의 변형과 핵분열의 기체방출을 전체 핵연료봉 길이로 고려하였다. 열역학적 평 형방정식을 얻기 위해서 Galerkin's Technique과 가상일의 원리를 사용하였고 역학적 해석을 위해서 탄성-소성, 크리프뿐만아니라 스엘링, 재배열, 고밀화 현상등을 고려하였다. 기하학적 모델에서는 4-결점 요소라 페레트 길이의 1/2만을 택하였다. 비선형식을 안정하게 해석하기 위해서 음해법을 도입하여 뉴튼-랩손 반복법을 적용하였다 이 코드의 검증은 해석해와 실험데이타로 비교하였다. 핵연료봉의 일반적인 거동은 axisymmetry system으로 계산하였고 균열된 페레트에 접촉하는 피복관의 거동은 R-$\theta$system을 사용하였다. 부하추종에 의한 피복관의 변형시효의 민감도는 출력율, 진동수, 진폭등으로 비교하였다.

  • PDF

Effect of Water Temperature and Photoperiod on the Oxygen Consumption of Four Different Strains of Red Seabream, Pagrus major

  • Oh, Sung-Yong;Choi, Hee Jung;Kim, Min-Suk;Park, Yong Joo;Myoung, Jung-Goo;Kwon, Joon Yeong;Choi, Cheol Young
    • 한국해양생명과학회지
    • /
    • 제1권2호
    • /
    • pp.109-116
    • /
    • 2016
  • We determined the effects of different water temperatures (15, 20, and 25℃) and photoperiod cycles (24L:0D, 12L:12D, and 0L:24D) on the oxygen consumption of the offspring of a cultured Japanese strain (JJ), a selected Korean strain (KK), and intraspecific hybrid strains (JK and KJ) of red seabream, Pagrus major, under starvation conditions. The different fish strains, water temperatures, and photoperiod cycles had effects on the mean oxygen consumption of fish. Oxygen consumption increased with increasing water temperatures for all photoperiod treatments (p<0.001). Fish held in continuous darkness (0L:24D) used consistently less oxygen than fish exposed to continuous light (p<0.05). The oxygen consumption of fish exposed to the light phase in a 12L:12D photoperiod was higher than that of fish in the dark phase of the 12L:12D cycle, and differences were significant in three of the strains: JJ (15℃), KK (15 and 20℃), and KJ (25℃). The oxygen consumption of the inbred (JJ and KK) and intraspecific hybrid (JK and KJ) strains varied with differing water temperatures and photoperiod cycles. The JK strain displayed significantly higher oxygen consumption than the other strains under all experimental conditions except 15℃ with a 0L:24D photoperiod. The JK and KJ strains usually showed the highest and lowest oxygen consumption values, respectively, whereas the inbred strains exhibited intermediate values. Oxygen consumption in the JJ and JK strains was usually higher than that of the KK and KJ strains. We propose that differences in the thermal sensitivity and photosensitization properties of the strains contribute to differences in their ability to adapt to changes in water temperature and photoperiod, thus resulting in differences in the amplitude of their metabolic rates.

VDT 작업 후의 조절기능 변화 (Changes in Accommodative Function after VDT Work)

  • 서은선
    • 한국안광학회지
    • /
    • 제17권3호
    • /
    • pp.285-291
    • /
    • 2012
  • 목적: VDT 작업이 조절기능에 주는 영향을 알아보고자 하였다. 방법: 조절기능 이상과 전신 및 안질환이 없고 교정수술을 받은 경험이 없는 대학생 48명(남 16명, 여 32명)을 대상으로 VDT 작업 전과 2시간 작업 후의 굴절력, 조절래그, 조절용이성, 상대조절력과 최대조절력, 순목 횟수 값을 측정하였다. 원거리 굴절교정 도수를 착용한 상태에서 모든 검사를 실시하였고 VDT 증후군의 자각증상에 관련된 항목에 대해 설문조사를 실시하였다. 결과: 2시간동안 VDT 작업 후의 굴절력변화는 0.23 D 증가하였고, 조절래그 변화량은 우안에서는 $0.17{\pm}0.42D$, 좌안에서는 $0.23{\pm}0.47D$(t=2.26, p=0.03) 만큼 증가하였고 통계적으로 유의한 차이를 나타내었다. 조절용이성과 상대조절력과 조절력은 VDT 작업 후에 모두 감소하는 경향을 보였으나, 순목 횟수는 증가하는 양상을 보였다. VDT 작업 후 안정피로가 33.4%, 어깨통증이 33.3%의 자각증상을 보였다. 결론: 2시간 VDT 작업 시간에 따라 조절래그는 증가하였고, 전반적인 조절기능의 능력이 감소하는 경향을 보였으며, 시각적 부담을 주는 증상으로는 안정피로가 가장 높은 자각도를 보였다.

공진주/비틂 전단(RC/TS)시험기를 이용한 건조 사질토의 변형특성 (Deformational Characteristics of Dry Sand Using Resonant Column / Torsional Shear Testing Equipment)

  • 김동수
    • 한국지반공학회지:지반
    • /
    • 제11권1호
    • /
    • pp.101-112
    • /
    • 1995
  • 동적하중을 받는 지반-구조물 시스템의 설계를 위해 전단탄성계수와 감쇠비로 표현되는 지반의 변형특성의 결정은 매우 중요하다. 본 논문에서는 공진주/비틂전단시험기를 이용하여 저변형률 및 중간 변형률하에서 건조사질토의 변형특성을 연구하였다. 동적시험인 공진주시험과 반복시험인 비틀전단시험을 동일한 공시 체를 이용하여 실시하였다. 진동측정시스템을 개량하여 응력 -변형관계가 하중반복회수와 전단변형률의 크기에 영향을 받지않는 선형영역을 찾았으며 이 영역에서 이력감쇠가 존재함을 나타내었다. 반복한계변형률 이상에서는 하중반복회수에 따라 전단탄성계수는 증가하고 감쇠비는 감소하였다. 사질토의 전단탄성계수와 감쇠비는 진동주파수에 영향을 받지 않으며 의사정적시험인 비틈전단시험에서 변형특성과 동적시험인 공진주 시험에서 얻은 값은 비교시 하중반복회수의 영향을 고려하면 동일하다. 그러므로 공진주l비틀전단시 험을 통해 얻은 변형특성은 지반-구조물시스템의 동적해석은 물론 정적해석에서도 적용할 수 있다.

  • PDF

Compressive performance of RAC filled GFRP tube-profile steel composite columns under axial loads

  • Ma, Hui;Bai, Hengyu;Zhao, Yanli;Liu, Yunhe;Zhang, Peng
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.335-349
    • /
    • 2019
  • To investigate the axial compressive performance of the recycled aggregate concrete (RAC) filled glass fiber reinforced polymer (GFRP) tube and profile steel composite columns, static loading tests were carried out on 18 specimens under axial loads in this study, including 7 RAC filled GFRP tube columns and 11 RAC filled GFRP tube-profile steel composite columns. The design parameters include recycled coarse aggregate (RCA) replacement percentage, profile steel ratio, slenderness ratio and RAC strength. The failure process, failure modes, axial stress-strain curves, strain development and axial bearing capacity of all specimens were mainly analyzed in detail. The experimental results show that the GFRP tube had strong restraint ability to RAC material and the profile steel could improve the axial compressive performance of the columns. The failure modes of the columns can be summarized as follow: the profile steel in the composite columns yielded first, then the internal RAC material was crushed, and finally the fiberglass of the external GFRP tube was seriously torn, resulting in the final failure of columns. The axial bearing capacity of the columns decreased with the increase of RCA replacement percentage and the maximum decreasing amplitude was 11.10%. In addition, the slenderness ratio had an adverse effect on the axial bearing capacity of the columns. However, the strength of the RAC material could effectively improve the axial bearing capacity of the columns, but their deformability decreased. In addition, the increasing profile steel ratio contributed to the axial compressive capacity of the composite columns. Based on the above analysis, a formula for calculating the bearing capacity of composite columns under axial compression load is proposed, and the adverse effects of slenderness ratio and RCA replacement percentage are considered.