• 제목/요약/키워드: Story shear force

검색결과 153건 처리시간 0.023초

Study on seismic retrofit of structures using SPSW systems and LYP steel material

  • Zirakian, Tadeh;Zhang, Jian
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.1-23
    • /
    • 2016
  • Steel plate shear walls (SPSWs) have been shown to be efficient lateral force-resisting systems, which are increasingly used in new and retrofit construction. These structural systems are designed with either stiffened and stocky or unstiffened and slender web plates based on disparate structural and economical considerations. Based on some limited reported studies, on the other hand, employment of low yield point (LYP) steel infill plates with extremely low yield strength, and high ductility as well as elongation properties is found to facilitate the design and improve the structural behavior and seismic performance of the SPSW systems. On this basis, this paper reports system-level investigations on the seismic response assessment of multi-story SPSW frames under the action of earthquake ground motions. The effectiveness of the strip model in representing the behaviors of SPSWs with different buckling and yielding properties is primarily verified. Subsequently, the structural and seismic performances of several code-designed and retrofitted SPSW frames with conventional and LYP steel infill plates are investigated through detailed modal and nonlinear time-history analyses. Evaluation of various seismic response parameters including drift, acceleration, base shear and moment, column axial load, and web-plate ductility demands, demonstrates the capabilities of SPSW systems in improving the seismic performance of structures and reveals various advantages of use of LYP steel material in seismic design and retrofit of SPSW systems, in particular, application of LYP steel infill plates of double thickness in seismic retrofit of conventional steel and code-designed SPSW frames.

편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core)

  • 김성용;김경남;윤태호
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.490-498
    • /
    • 2020
  • 본 논문에서는 편심코아를 가지는 저층 필로티 건물의 내진거동을 해석하고 결과를 분석하였다. 본 논문에서는 저층 필로티 건물의 시공사례 중 KBC2005기준에 준하여 설계된 편심코어를 가지는 건물들의 설계자료를 수집하여, 대표적인 편심 필로티 건물을 프로토타입으로 선정하여 KDS41기준에 준하여 내진거동을 해석하고 결과를 분석하였다. 연구결과 편심코어를 가지는 필로티 건물의 경우 X방향은 소성거동, Y방향은 탄성거동을 하는 것으로 평가 되었다. 연구대상 건물의 층간 변위를 확인한 결과 최대변위 δ=67.51mm로 코어가 평면 중심에 위치하는 경우보다 층간 변위량이 더 큰 것으로 평가 되었다. 해석결과에서 층간 변위 비율은 법적 규준 이내인 것으로 평가되었다. 또한 변위 비율은 1층 필로티 구간이 2~4층 부분보다 확연히 높은 걸로 평가 되었으며, 저층 필로티 구조물의 경우 1층 라멘조 부분이 횡력에 취약한 것으로 평가되었다. 편심코어로 인하여 구조물 전체의 강성중심이 질량중심과 이격되어 있어 코어 반대쪽의 필로티 기둥에서 항복과 소성힌지 발생이 시작되므로 내진설계와 내진보강시 이에 대한 고려가 필요하다. 따라서, 편심코어를 가지는 저층 필로티 건물의 내진설계 및 내진보강시 필로티 구조의 횡변위 감소와 횡력저항능력을 보강할 필요가 있다.

The effects of vertical earthquake motion on an R/C structure

  • Bas, Selcuk;Kalkan, Ilker
    • Structural Engineering and Mechanics
    • /
    • 제59권4호
    • /
    • pp.719-737
    • /
    • 2016
  • The present study investigated the earthquake behavior of R/C structures considering the vertical earthquake motion with the help of a comparative study. For this aim, the linear time-history analyses of a high-rise R/C structure designed according to TSC-2007 requirements were conducted including and excluding the vertical earthquake motion. Earthquake records used in the analyses were selected based on the ratio of vertical peak acceleration to horizontal peak acceleration (V/H). The frequency-domain analyses of the earthquake records were also performed to compare the dominant frequency of the records with that of the structure. Based on the results obtained from the time-history analyses under the earthquake loading with (H+V) and without the vertical earthquake motion (H), the value of the overturning moment and the top-story vertical displacement were found to relatively increase when considering the vertical earthquake motion. The base shear force was also affected by this motion; however, its increase was lower compared to the overturning moment and the top-story vertical displacement. The other two parameters, the top-story lateral displacement and the top-story rotation angle, barely changed under H and H+V loading cases. Modal damping ratios and their variations in horizontal and vertical directions were also estimated using response acceleration records. No significant change in the horizontal damping ratio was observed whereas the vertical modal damping ratio noticeably increased under H+V loading. The results obtained from this study indicate that the desired structural earthquake performance cannot be provided under H+V loading due to the excessive increase in the overturning moment, and that the vertical damping ratio should be estimated considering the vertical earthquake motion.

Cable-pulley brace to improve story drift distribution of MRFs with large openings

  • Zahrai, Seyed Mehdi;Mousavi, Seyed Amin
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.863-882
    • /
    • 2016
  • This study aims to introduce a new bracing system by which even super-wide frames with large openings can be braced. The proposed system, hereafter called Cable-Pulley Brace (CPB), is a tension-only bracing system with a rectilinear configuration. In CPB, a wire rope passes through a rectilinear path around the opening(s) and connects the lower corner of the frame to its opposite upper one. CPB is a secondary load resisting system with a nonlinear-elastic hysteretic behavior due to its initial pre-tension load. As a result, the required energy dissipation would be provided by the MRF itself, and the main intention of using CPB is to contribute to the initial and post-yield stiffness of the whole system. Using a stiffness calibration technique, optimum placement of the CPBs is discussed to yield a uniform displacement demand along the height of the structure. A displacement-based design procedure is proposed by which the MRF with CPB can be designed to achieve a uniform distribution of inter-story drifts with predefined values. Obtained results indicated that CPB leads to significant reductions in maximum and residual deformations of the MRF at the expense of minor increase in the maximum base shear and developed axial force demands in the columns. In the case of a typical 5-story residential building, compared to SMRF system, CPB system reduces maximum amounts of inter-story and residual drifts by 35% and 70%, respectively. Moreover, openings of the frame are not interrupted by the CPB. This is the most appealing feature of the proposed bracing system from architectural point of view.

합성반강접 접합부를 갖는 2차원 8층 비가새 철골골조의 동적거동 (Dynamic Behavior of 2D 8-Story Unbraced Steel Frame with Partially Restrained Composite Connection)

  • 강석봉;이경택
    • 한국강구조학회 논문집
    • /
    • 제19권5호
    • /
    • pp.503-513
    • /
    • 2007
  • 구조물의 지진응답은 구조물의 강성도에 영향을 미치는 접합부의 특성에 영향을 받는다. 본 연구에서는 합성반강접 접합부를 갖는 2차원 8층 비가새 철골구조물에 대하여 동적 비선형 해석 프로그램을 이용한 푸쉬오버 해석과 시간이력해석을 실시하여 구조물의 거동을 예측하였다. 접합부 비선형 모멘트-회전 특성, 합성보 및 철골기둥의 재료 비선형 특성을 고려하여 구조해석을 실시하였다. 합성반강접 접합부를 완전 강접합부로 이상화하면 푸쉬오버 해석에서 구조물의 초기강성도와 종국강도가 증가되었고 시간이력해석에서는 밑면전단력, 최대층간변위, 보 및 기둥에 발생되는 최대 휨모멘트가 접합부 강성 및 이력거동의 영향을 받았다. 최대지반가속도가 0.4g인 지진파에 대하여 합성반강접 구조물에서는 FEMA 273의 최대 층간변위에 대한 인명손상방지 기준을 만족하였으며 보와 기둥이 비탄성 거동을 경험하지 않은 반면 완전 강접합부로 이상화한 구조물에서는 보 및 기둥이 비탄성 거동을 경험하였다.

Reliability assessment of semi-active control of structures with MR damper

  • Hadidi, Ali;Azar, Bahman Farahmand;Shirgir, Sina
    • Earthquakes and Structures
    • /
    • 제17권2호
    • /
    • pp.131-141
    • /
    • 2019
  • Structural control systems have uncertainties in their structural parameters and control devices which by using reliability analysis, uncertainty can be modeled. In this paper, reliability of controlled structures equipped with semi-active Magneto-Rheological (MR) dampers is investigated. For this purpose, at first, the effect of the structural parameters and damper parameters on the reliability of the seismic responses are evaluated. Then, the reliability of MR damper force is considered for expected levels of performance. For sensitivity analysis of the parameters exist in Bouc- Wen model for predicting the damper force, the importance vector is utilized. The improved first-order reliability method (FORM), is used to reliability analysis. As a case study, an 11-story shear building equipped with 3 MR dampers is selected and numerically obtained experimental data of a 1000 kN MR damper is assumed to study the reliability of the MR damper performance for expected levels. The results show that the standard deviation of random variables affects structural reliability as an uncertainty factor. Thus, the effect of uncertainty existed in the structural model parameters on the reliability of the structure is more than the uncertainty in the damper parameters. Also, the reliability analysis of the MR damper performance show that to achieve the highest levels of nominal capacity of the damper, the probability of failure is greatly increased. Furthermore, by using sensitivity analysis, the Bouc-Wen model parameters which have great importance in predicting damper force can be identified.

Numerical investigations of structure-soil-structure interaction on footing forces due to adjacent building

  • Shrish Chandrawanshi;Vivek Garg
    • Earthquakes and Structures
    • /
    • 제26권6호
    • /
    • pp.477-487
    • /
    • 2024
  • The interaction between multiple structures through the supporting soil media, known as structure-soil-structure interaction (SSSI), has become an increasingly important issue due to rapid urbanization. There is a need to investigate the effect of SSSI on the structural response of buildings compared to non-interaction analysis (NIA) and soil-structure interaction (SSI) analysis. In the present study, two identical 4-bay×4-bay, three-story RCC buildings are modeled adjacent to each other with a soil domain beneath it to investigate the effect of SSSI on the forces experienced by footings under gravity and seismic load cases. The ANSYS software is used for modeling various non-interaction and interaction models which work on the principle of FEM. The results indicate that in most of the footings, the SSSI effect causes a significant redistribution of forces compared to SSI and NIA under both gravity and seismic load cases. The maximum interaction effect is observed on the footings that are closer to the adjacent building. The axial force, shear force and bending moment values on these footings show that SSI causes a significant increase in these values compared to non-interaction analysis but the presence of adjacent building relieves these forces significantly.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

Validation of the seismic response of an RC frame building with masonry infill walls - The case of the 2017 Mexico earthquake

  • Albornoz, Tania C.;Massone, Leonardo M.;Carrillo, Julian;Hernandez, Francisco;Alberto, Yolanda
    • Advances in Computational Design
    • /
    • 제7권3호
    • /
    • pp.229-251
    • /
    • 2022
  • In 2017, an intraplate earthquake of Mw 7.1 occurred 120 km from Mexico City (CDMX). Most collapsed structural buildings stroked by the earthquake were flat slab systems joined to reinforced concrete (RC) columns, unreinforced masonry, confined masonry, and dual systems. This article presents the simulated response of an actual six-story RC frame building with masonry infill walls that did not collapse during the 2017 earthquake. It has a structural system similar to that of many of the collapsed buildings and is located in a high seismic amplification zone. Five 3D numerical models were used in the study to model the seismic response of the building. The building dynamic properties were identified using an ambient vibration test (AVT), enabling validation of the building's finite element models. Several assumptions were made to calibrate the numerical model to the properties identified from the AVT, such as the presence of adjacent buildings, variations in masonry properties, soil-foundation-structure interaction, and the contribution of non-structural elements. The results showed that the infill masonry wall would act as a compression strut and crack along the transverse direction because the shear stresses in the original model (0.85 MPa) exceeded the shear strength (0.38 MPa). In compression, the strut presents lower stresses (3.42 MPa) well below its capacity (6.8 MPa). Although the non-structural elements were not considered to be part of the lateral resistant system, the results showed that these elements could contribute by resisting part of the base shear force, reaching a force of 82 kN.

진동대 실험을 통한 조립식 스틸 전단 패널의 비선형 동적 거동 (Nonlinear Dynamic Behavior of a Cold-Formed Steel Shear Panel by Shaketable Tests)

  • 김태완;이문성
    • 한국지진공학회논문집
    • /
    • 제9권6호
    • /
    • pp.31-39
    • /
    • 2005
  • 본 연구의 목적은 인장으로만 저항하는 경사진 스트랩과 기둥으로 구성된 조립식 스틸 (CFS) 전단 패널의 지진하중에 대한 비선형 거동을 조사하는 것이며, 이를 위해 실제 크기의 2층 건물을 설계한 후 진동대 실험을 수행하였다. CFS 전단 패널은 연성이 큰 경사진 스트랩이 주 횡 저항 시스템으로 작용하며, 중력 저항 부재인 기둥은 'ㄷ'자 형태의 스터드를 용접한 것으로서 비콤펙트단면을 가지며 국부 좌굴로 인해 자신의 최대 모멘트 강도를 발휘하지 못한다. 진동대 실험을 통하여 스트랩이 대부분의 에너지를 인장측만으로 핀칭 형태를 가지며 소산하며, 기둥은 국부 좌굴로 인해 기둥은 자신의 최대 강도를 발휘하지 못하나 전체 에너지 소산에 공헌을 하고 있음을 보여주었다. 본 연구 결과, 비록 구조물이 단순할지라도 지진 시 실제 비선형 거동을 진동대 실험으로 조사하는 것은 매우 중요한 과정임을 확인하였다.