• Title/Summary/Keyword: Storage performance

검색결과 3,082건 처리시간 0.034초

빙축열조 성능향상에 관한 연구 (A Basic Study for Improvement of Performance of Ice Thermal Storage in Ice Storage Tank)

  • 박정원;이원섭
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.11-20
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual air-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. In the influence of the inlet port type, the inflowing water in the distributor type diffuses through the whole storage tank more than in the slot type. In case of the flow process in the ice storage tank, the upward flow type in the charging process and the downward flow type in the discharging process make the stratification well, thereby the loss of energy wored be smaller. The influence of the inlet temperature difference and the change of the inlet flow rate is intensive when the temperature difference is larger, the flow rate is smaller in case of charging and the results are opposite in case of discharging with the reason that the good coduction condition. The total effeciency of the ice thermal storge system is 73% on condition that the porosity in the thermal storage tank is 0.55. This result shows that cylinderical ice storage tank has better storage capacity than rectangular type in case of the same porosity.

  • PDF

홀로그래픽 저장장치를 위한 오류 정정 4/6 변조 부호의 어긋남 채널 성능 (Mis-alignment Channel Performance of Error Correcting 4/6 Modulation Codes for Holographic Data Storage)

  • 양기주;김진영;이재진
    • 한국통신학회논문지
    • /
    • 제35권12C호
    • /
    • pp.971-976
    • /
    • 2010
  • 본 논문은 홀로그래픽 저장장치를 위한 오류 정정 4/6 변조 부호에 대해서 알아보고, 어긋남이 존재하는 상황에서 성능을 알아보았다. 홀로그래픽 저장장치는 2차원 인접 심볼간 간섭이 생기는 채널로, 읽기 성능을 높이기 위해 변조 부호를 사용해야 한다. 이러한 변조 부호에 길쌈 구조가 더해지면 오류 정정 능력을 가지게 된다. 오류 정정 4/6 변조 부호는 기존의 변조 부호보다 성능이 우수하였고, 어긋남에 대해서도 강인한 성능을 보여준다.

슬래브축열 시스템 설계인자의 감도해석 (A Sensitivity Analysis of Design Factors of Air-Conditioning System with Slab Thermal Storage)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2008
  • In this paper, the sensitivity analysis was examined about the main factors that compose an air-conditioning system with slab thermal storage by using the analytic solution. Those factors are the insulation performance of floor slab surface, the slab thickness, the heat capacity of floor slab, the air change rate, and the insulation performance of the wall. The slab thickness and heat capacity of floor slab that minimize heating loads was gained by sensitivity analysis. It is became clear that the insulation performance of slab surface, high airtightness and high heat insulation are important design factors in air conditioning system with slab thermal storage.

  • PDF

축열조를 채용한 복합 포물형 태양열 집열기(CPC) 시스템의 연중 열적 성능 해석 (Thermal Performance Analysis of Compound Parabolic Collector (CPC) System Employing Storage Tank Through a Year)

  • 임석규;정영관;김경훈
    • 한국수소및신에너지학회논문집
    • /
    • 제30권4호
    • /
    • pp.376-383
    • /
    • 2019
  • This paper presents of thermal performance analysis by using mathematical models for a compound parabolic collector (CPC) system employing heat storage tank. The thermal performance including insolation energy, heat loss from collector system, useful energy, collector efficiency, and temperature of storage tank were theoretically investigated through a year using monthly-average meteorological data at Seoul. The simulated results showed that the CPC systems are suitable for the applications of higher temperature than flat plate collector (FPC) systems.

클라우드 스토리지 최적화를 위한 고속 캐싱 및 대용량 파일 전송 기법 (A Scheme on High-Performance Caching and High-Capacity File Transmission for Cloud Storage Optimization)

  • 김태훈;김정한;엄영익
    • 한국통신학회논문지
    • /
    • 제37권8C호
    • /
    • pp.670-679
    • /
    • 2012
  • 최근 클라우드 컴퓨팅 환경의 보급과 함께 스토리지의 데이터양이 급증함에 따라 그에 따른 스토리지 저장 비용이 빠르게 증가하고 있다. 더불어, 사용자들의 다양한 서비스 및 데이터 요청으로 클라우드 스토리지의 부하 또한 급증하고 있다. 이러한 문제를 해결하기 위해 분산 파일 시스템을 통한 저비용 고성능 스토리지 환경을 제공하고자 하는 기존의 연구가 있었으나, 이에는 데이터 병렬처리, 임의위치 접근처리, 빈번한 작은 워크로드 접근처리 등의 취약점이 존재한다. 최근에는 캐싱 기술을 이용하여 이를 개선하려는 연구가 주목받고 있다. 본 논문에서는 분산 파일 시스템 환경에서 병렬 캐싱, 분산 캐싱과 공유 자원을 고려한 데이터 병렬 전송방법을 제공하는 CHPC(Cloud storage High-Performance Caching) 구조를 제안하며, 또한 이를 기존의 방법들과 비교 평가하여 스토리지 부하를 최적화하는 방법을 제시한다. 더불어, 제안 기법이 기존 클라우드 시스템에 비하여 스토리지 서버의 디스크 입출력 감소, 서버로 데이터의 요청이 집중되어 발생하는 병목현상 방지, 각 클라이언트의 중복되는 페이지 캐시 제거, 데이터 전송률 향상의 장점을 가짐을 보인다.

SCST를 이용한 All Flash Array 스토리지 가상화 (All Flash Array Storage Virtualisation using SCST)

  • 허희성;메히디;이광수;김덕환
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제20권10호
    • /
    • pp.525-533
    • /
    • 2014
  • SCST(The generic SCSI target subsystem for Linux)는 개발자가 SCSI 타겟 스토리지를 구성할 수 있게 하는 오픈소스 소프트웨어이며, 스토리지 네트워크 구성을 위해 iSCSI, FC, SRP 등의 다양한 SCSI 네트워크 프로토콜을 지원한다. 본 논문에서는 SCST를 이용한 스토리지 가상화 방법을 제안하고 고성능 스토리지인 All Flash Array를 4Gb 파이버 채널, 10Gb 이더넷, 40Gb 인피니밴드를 통해 가상화하며, 가상화된 All Flash Array의 성능을 고찰한다. 실험 결과 40Gb 인피니밴드를 통해 가상화된 All Flash Array가 세 경우 중 가장 높은 성능을 보였다. 40Gb 인피니밴드를 통해 가상화된 All Flash Array는 SCSI 타겟 시스템에 연결된 All Flash Array에 비해 순차/임의 읽기의 경우에 각각 78%, 79%의 성능을 보였으며, 순차/임의쓰기의 경우에는 83%, 88%의 성능을 보임을 확인하였다.

성층축열조의 성능에 대한 설계인자의 영향 (Effect of Design Factors on the Performance of Stratified Thermal Storage Tank)

  • 정재동;박주혁;조성환
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1077-1083
    • /
    • 2004
  • This study is to systematically analyze the effect of various kinds of design factors on the performance of stratified thermal storage tank. Taguchi method, known as a very reasonable tool in the parametric study, is employed in the present work. Three dimensional unsteady numerical experiment is conducted for 4 design parameters of stratified thermal storage tank: inlet Reynolds number, Froude number, diffuser size d with 3 levels (Re=400, 800, 1200, Fr=0.5, 1.0, 2.0 and d=150 mm, 200mm, 300 mm) and diffuser shape with 2 levels. Orthogonal array $L_{18}(2{\times}3^7)$ is adopted for the analysis of variance. The result gives quantitative estimation of the various design parameters affecting the performance and helps to select the main factors for the optimum design of stratified thermal storage tank. Reynolds number is found to be the most dominant parameter and the diffuser shape plays significant role on the performance of stratified thermal storage tank. Based on this finding, the prior questions on the contribution of the diffuser shape proposed by the authors become clear. The optimum condition for the performance is a set of d=300mm, Re=800, and radial regulated plate diffuser. Conformation test shows the repeatability in the analysis and $1.3\%$ difference between the estimated thermocline thickness and that of numerical result.

스토리지 내 프로세싱 방식을 사용한 그래프 프로세싱의 최적화 방법 (Optimization of Graph Processing based on In-Storage Processing)

  • 송내영;한혁;염헌영
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제23권8호
    • /
    • pp.473-480
    • /
    • 2017
  • 최근 들어 플래시 메모리 Solid State Driver(SSD)와 같은 반도체 기반 저장장치가 고성능으로 발전하면서 저장장치 내부 컨트롤러의 CPU와 메모리 같은 자원을 응용의 요구에 맞추어 최적으로 활용해보고자 하는 움직임이 있었다. 이러한 개념을 스토리지 내 프로세싱 방식(In-Storage Processing, ISP)이라고 한다. ISP의 기능이 탑재된 저장장치에서는 호스트에서 수행하던 연산의 일부를 나누어 처리할 수 있으므로 호스트의 부하가 줄어들고 저장장치 내에서 데이터가 가공되어 처리되기 때문에 호스트까지의 데이터 전달 시간이 줄어든다. 본 논문에서는 이러한 ISP 기능을 활용하여 그래프 질의 처리를 최적화하기 위한 방식을 제안하고, 제안된 최적화 그래프 처리 방식이 graph500 벤치마크의 성능을 최대 20%까지 향상 시켰음을 보여준다.

태양열과 지열을 이용한 난방용 공기순환시스템 기초연구 - 태양열을 이용한 트롬월식의 축열성능 중심으로 - (A Basic Study on the Air Circulation System for Heating using Solar and Geothermal Heat - Focused on Trombe Wall Thermal Storage Performance using Solar Heat -)

  • 김병윤;최용석
    • 한국농촌건축학회논문집
    • /
    • 제19권4호
    • /
    • pp.49-56
    • /
    • 2017
  • Each country in the world currently concentrates on shifting into clean energy, which can be alternative energy, for global environment protection and solution to the problem of fossil fuel depletion. The Korean government is predicted to develop renewable energy, such as solar power, ground power, and offshore wind power, and to increase their supply ratios by ending the use of coals and nuclear power plants. This study conducted experiments on thermal storage performance of Trombe wall thermal storage materials using solar power and simulations in order to offer baseline data for the development of a hybrid air circulation system for heating that can maximize efficiency by simultaneously using solar and geothermal power. The study results are as follows: (1) In all the specimens with 3m, 5m, and 7m in the length of thermal storage pipe, $5.7^{\circ}C$, $7.8^{\circ}C$, and $10.5^{\circ}C$ rose, respectively, as the thermal storage effect of the specimens attaching insulation film and black tape to the general funnel. They were most excellent in terms of thermal storage effect. (2) As a result of thermal performance evaluation on the II type specimens, II-3 ($7.8^{\circ}C$ rise) > II-4 ($5.3^{\circ}C$ rise) > II-1 ($3.9^{\circ}C$ rise) > II-2 ($2.3^{\circ}C$ rise) was revealed, and thus II-3 (insulation film + black tape) was most effective as shown in the I type. (3) This study analyzed air current and temperature distribution inside of the greenhouse by linking actually measured values and simulation interpretation results through the interpretation of CFD (computational fluid dynamics). As a result, the parts absorbing heat and discharging heat around the thermal storage pipe could be visibly classified, and temperature distribution inside of the greenhouse around the thermal storage pipe could be figured out.

Blockchain-based Data Storage Security Architecture for e-Health Care Systems: A Case of Government of Tanzania Hospital Management Information System

  • Mnyawi, Richard;Kombe, Cleverence;Sam, Anael;Nyambo, Devotha
    • International Journal of Computer Science & Network Security
    • /
    • 제22권3호
    • /
    • pp.364-374
    • /
    • 2022
  • Health information systems (HIS) are facing security challenges on data privacy and confidentiality. These challenges are based on centralized system architecture creating a target for malicious attacks. Blockchain technology has emerged as a trending technology with the potential to improve data security. Despite the effectiveness of this technology, still HIS are suffering from a lack of data privacy and confidentiality. This paper presents a blockchain-based data storage security architecture integrated with an e-Health care system to improve its security. The study employed a qualitative research method where data were collected using interviews and document analysis. Execute-order-validate Fabric's storage security architecture was implemented through private data collection, which is the combination of the actual private data stored in a private state, and a hash of that private data to guarantee data privacy. The key findings of this research show that data privacy and confidentiality are attained through a private data policy. Network peers are decentralized with blockchain only for hash storage to avoid storage challenges. Cost-effectiveness is achieved through data storage within a database of a Hyperledger Fabric. The overall performance of Fabric is higher than Ethereum. Ethereum's low performance is due to its execute-validate architecture which has high computation power with transaction inconsistencies. E-Health care system administrators should be trained and engaged with blockchain architectural designs for health data storage security. Health policymakers should be aware of blockchain technology and make use of the findings. The scientific contribution of this study is based on; cost-effectiveness of secured data storage, the use of hashes of network data stored in each node, and low energy consumption of Fabric leading to high performance.