• 제목/요약/키워드: Storage Systems

검색결과 3,084건 처리시간 0.05초

Design of type 316L stainless steel 700 ℃ high-temperature piping

  • Hyeong-Yeon Lee;Hyeonil Kim;Jaehyuk Eoh
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3581-3590
    • /
    • 2023
  • High-temperature design evaluations were conducted on Type 316L stainless steel piping for a 700 ℃ large-capacity thermal energy storage verification test loop (TESET) under construction at KAERI. The hot leg piping with sodium coolant at 700 ℃ connects the main components of the loop heater, hot storage tank, and air-to-sodium heat exchanger. Currently, the design rules of ASME B31.1 and RCC-MRx provide design procedures for high-temperature piping in the creep range for Type 316L stainless steel. However, the design material properties around 700 ℃ are not available in those rules. Therefore, a number of material tests, including creep tests at various temperatures, were conducted to determine the insufficient material properties and relevant design coefficients so that high-temperature design on the 700 ℃ piping may be possible. It was shown that Type 316L stainless steel can be used in a 700 ℃ high-temperature piping system of Generation IV reactor systems or a renewable energy systems, such as thermal energy storage systems, for a limited operation time.

Applications and Challenges of Lithium-Sulfur Electrochemical Batteries

  • Mohammed Jasim M. Al Essa
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.1-13
    • /
    • 2024
  • This paper presents applications of lithium-sulfur (Li-S) energy storage batteries, while showing merits and demerits of several techniques to mitigate their electrochemical challenges. Unmanned aerial vehicles, electric cars, and grid-scale energy storage systems represent main applications of Li-S batteries due to their low cost, high specific capacity, and light weight. However, polysulfide shuttle effects, low conductivities, and low coulombic efficiencies signify key challenges of Li-S batteries, causing high volumetric changes, dendritic growths, and limited cycling performances. Solid-state electrolytes, interfacial interlayers, and electrocatalysts denote promising methods to mitigate such challenges. Moreover, nanomaterials have capability to improve kinetic reactions of Li-S batteries based on several properties of nanoparticles to immobilize sulfur in cathodes, stabilizing lithium in anodes while controlling volumetric growths. Li-S energy storage technologies are able to satisfy requirements of future markets for advanced rechargeable batteries with high-power densities and low costs, considering environmentally friendly systems based on renewable energy sources.

초경량 사물인터넷을 위한 비휘발성램 스토리지 성능평가 및 분석 (Performance Evaluation and Analysis of NVM Storage for Ultra-Light Internet of Things)

  • 이은지;유승훈;반효경
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.181-186
    • /
    • 2015
  • 최근 통신 빛 반도체 기술의 급격한 발전과 함께 소규모 기기에도 컴퓨팅 기능을 탑재하는 사물인터넷 시장이 부상하고 있다. 사물인터넷을 위한 저장장치는 전력소모와 물리적 크기에 제한이 있어 기존 HDD나 SSD 대신 NVRAM 기반의 스토리지가 사용될 것으로 전망되고 있다. 그러나 현재 사물인터넷 플랫폼 기술은 기존의 전통적인 스토리지를 타겟으로 설계되어 NVRAM 스토리지에서는 다양한 비효율성을 초래할 수 있다. 본 논문은 현재의 다양한 운영체제의 I/O 기법들의 효용성과 성능을 NVRAM 스토리지 환경에서 평가하고 분석하여 향후 사물인터넷을 위한 스토리지 기술에 대해 방향성을 제시한다.

Skip-k 저장방식 (Skip-k Storage Policy)

  • 임상규
    • 대한산업공학회지
    • /
    • 제19권2호
    • /
    • pp.95-103
    • /
    • 1993
  • We address a new storage policy, called Skip-k storage, which gives storing priority to the items with relatively higher turnover rates. Applying the policy in storage systems such as AS/RS will reduce expected travel distance considerably. We analyze system behavior and find an appropriate skip size expressed by the system parameters in case arrival rates become larger enough.

  • PDF

대칭비교에 의한 Stable Minimum Storage 머징의 복잡도 (Complexity of Stable Minimum Storage Merging by Symmetric Comparisons)

  • 김복선
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국지능시스템학회 2007년도 추계학술대회 학술발표 논문집
    • /
    • pp.53-56
    • /
    • 2007
  • Symmerge is a stable minimum storage algorithm for merging that needs $O(mlog\frac{n}{m})$ element comparisons, where m and n are the sizes of the input sequences with m ${\leqq}$ n. According to the lower bound for merging, the algorithm is asymptotically optimal regarding the number of comparisons. The objective of this paper is to consider the relationship between m and n for the spanning case with the recursion level m-1.

  • PDF

철도차량 회생에너지 활용기술별 가선 손실 저감 효과 비교 분석 연구 (Electric Power Loss Comparison Study for Regenerative Utilization Technologies in DC Electric Railway Systems)

  • 이한상;김진학;김현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1597-1598
    • /
    • 2015
  • Regenerative power utilization is one of the most interesting issue in electric railway systems. Generally, technologies to utilize regenerative power from railway vehicles are railway substation with regenerative inverter, on-station energy storage systems, and on-board energy storage systems. In this paper, the electric power loss for those technologies is calculated and compared using DC electric railway system analysis algorithm.

  • PDF

On the Derivation of Safety Requirements and Specifications based Integrated System Operation Scenario for the Development of Unmanned Courier Storage Device Platform in Urban Areas

  • Lee, Sang Min;Park, Jae Min;Kim, Joo Uk;Kim, Young Min
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권4호
    • /
    • pp.103-111
    • /
    • 2021
  • In modern society, digital lifestyles are spreading to minimize contact with people and to receive contactless information. The spread trend has established an unmanned distribution system in which transactions through contactless technologies such as kiosks and chatbots are activated in face-to-face transactions with sellers and consumers. In order to streamline logistics supply worldwide, digital new deal based joint logistics hubs, unmanned courier storage platforms, and fresh logistics based last mile services have been developed into unmanned logistics systems, focusing on the intelligent logistics system automation process. Unmanned courier storage system installed in urban areas and home to daily logistics where volume is concentrated are provided with fresh logistics services through cold chain and receiving freights in contactless environments. Development is also underway to minimize safety accidents caused by courier services, such as managing various information based on the integrated control system. This paper defines the concept of integrated operation for the development of a platform for contactless unmanned courier storage device developed into next-generation logistics system. In addition, we intend to develop systems engineering-based output for deriving safety requirements and specifications by identifying risk sources that may occur in the operational scenario. Therefore, the goal is to establish a foundation for safety and reliability between interfaces of logistics systems to be installed in apartment and subway station environments that want to provide unmanned logistics services to various consumers.

마이크로그리드 운영에 따른 전력자립 향상을 위한 에너지저장장치의 적정보조금 산정 (Calculation of Appropriate Subsidies for Energy Storage System to Improve Power Self-sufficiency Consider Microgrid Operation)

  • 최연주;김성열
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.486-492
    • /
    • 2017
  • In recent years, renewable energy sources have been mentioned as solution to environmental regulation and energy supply-demand. Energy storage systems are needed to mitigate the intermittent output characteristics of renewable energy sources and to operate micro grid efficiently using renewable energy generation systems. However, despite the necessity of energy storage system, this cannot secure the economical efficiency of the energy storage system by high initial cost. In this paper, a micro grid is constructed to supply electric power to industrial customers by using solar power generation system and energy storage system among renewable energy generation power sources and operated to improve energy independence. In the case study, we use photovoltaic system which is representative renewable energy generation system. Unlike conventional photovoltaic system, this system uses floating photovoltaic system with the advantage of having high output and no land area limitations. It is operated for the purpose of improving energy independence in the micro grid. In order to secure economical efficiency, the energy storage system operates a micro grid with a minimum capacity. Finally, this paper calculates the appropriate subsidy for the energy storage capacity.

층 밀리 간섭계를 이용한 고체침지렌즈의 광학적 성능 평가 (Optical Performance Evaluation of SIL Assembly with Lateral Shearing Interferometer)

  • 이진의;김완진;최현;김태섭;윤용중;박노철;박영필
    • 정보저장시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.224-229
    • /
    • 2006
  • There has been studied flow to minimize the spot size to increase data capacity. Optical data storage devices are being developed near practical limits with wavelength and NA of 405nm and 0.85. There has been studied many types of next generation storage devices such as blu-ray multilayer system, probe based data storage and holographic data storage. Among these data storage devices, solid immersion lens(SIL) based near field recording (NFR) has been widely studied. In this system, SIL is the key component that focuses the laser beam with a very small size which enables ultra high data capacity. Therefore, optical performance evaluation system is required for SIL assembly. In this dissertation, a simple and accurate SIL assembly measurement method is proposed with wedge plate lateral shearing interferometer(LSI). Wedge plate LSI is cheaper than commercialized interferometer, robust to the vibration and the moving distance for phase shifting is large that is order of micrometer. We designed the thickness, wedge angle, material, surface quality and wavelength of wedge plate as 1mm, 0.02degree, fused silica, lamda/10(10-5) and 405nm, respectively. Also, we confirmed simulation and experimental results with quantitative analysis. This simple wedge plate LSI can be applied to different types of SIL such as solid immersion mirror(SIM), hemispherical, super-hemispherical and elliptical SIL.

  • PDF

등고선 접근방식을 이용한 복식명령작업 저장위치형태의 결정 (A Contour Line Approach to Storage Location Configurations for Dual Command Operations)

  • 박병춘
    • 대한산업공학회지
    • /
    • 제24권4호
    • /
    • pp.519-528
    • /
    • 1998
  • This paper examines the effect of storage location configurations on dual command cycle times for the efficient operation of automated storage/retrieval systems. We use a contour line approach to determine storage location configurations. We present a contour line configuration generating scheme and a location indexing scheme. Given a contour line configuration, the location indexing scheme provides a unique priority to each location. The location priority is then used for determining the storage location of an incoming load. To investigate the effect of alternative contour line configurations on dual command cycle times, we perform a series of experiments under various storage policies.

  • PDF