• 제목/요약/키워드: Storage System

검색결과 6,977건 처리시간 0.039초

수소트럭 수소저장시스템에 대한 구조안전성 및 기밀성능평가 (Evaluation of Structural Safety and Leak Test for Hydrogen Fuel Cell-Based Truck Storage Systems)

  • 김다은;염지웅;최성준;김영규;조성민
    • 한국기계가공학회지
    • /
    • 제19권11호
    • /
    • pp.1-7
    • /
    • 2020
  • Recently, hydrogen has gained considerable attention as an eco-friendly fuel, which helps in reducing carbon dioxide content. Specifically, there is a growing interest in vehicles powered by a hydrogen fuel cell, which is spotlighted as an environmental-friendly alternative. A hydrogen transport system, fuel cell system, fuel supply system, power management system, and hydrogen storage system are key parts of a hydrogen fuel cell truck. In this study, a hydrogen storage system is built and analyzed. The expansion length of the storage vessel at maximum operating pressure (87.5 MPa) was calculated with ABAQUS, and then the optimized system was designed and built. The leak and bubble tests were performed on the built storage system. The leakage of the system was measured to be under 5 cc/hr. Hence, it can be used as a research test for the safety evaluation of leading systems of hydrogen fuel-powered commercial vehicles.

암반동굴식 지하 LNG 저장 시스템 설계를 위한 기화율의 산정 (Determination of Boil-Off gas Ratio for the Design of Underground LNG Storage System in Rock Cavern)

  • 정소걸;이희석;정우철;박의섭
    • 터널과지하공간
    • /
    • 제17권1호
    • /
    • pp.56-65
    • /
    • 2007
  • 기존의 단열 시스템, 지하동굴 건설기술과 새로운 동결링 방벽기술을 결합하여 암반동굴식 지하 LNG 저장시스템이 개발되었다. 이 저장시스템의 기술적 적합성은 파일럿 동굴 실증시설의 건설과 운영을 통해 검증된 바 있으며, 조만간 실규모 프로젝트가 시작될 예정이다. LNG 저장시스템에서 중요한 사항 중의 하나는 극저온 열전달을 통해 장기간의 운영 기간동안 열손실을 최소화하는 것이다. 이 논문은 지하 LNG 저장 시스템의 설계를 위한 몇 가지 중요한 열전달 해석 결과를 제시하며, 기화율, 단열재 두께와 같은 설계 변수를 결정하기 위해 일련의 실규모 동굴에 대한 열전달 및 열-수리 해석을 실시하였다. 열-수리 연계해석결과 LNG 저장시설의 기화율은 초기 단계에서 0.04 %/day로 떨어져 유지되는 것으로 나타났다. 이 값은 암반내 존재하는 불연속면을 고려할 때 더욱 낮아질 수 있을 것으로 판단된다.

클라우드 스토리지를 최종 저장 장치로 사용하는 인메모리 파일 시스템 (In-Memory File System Backed by Cloud Storage Services as Permanent Storages)

  • 이경준;김지원;류성태;한환수
    • 정보과학회 논문지
    • /
    • 제43권8호
    • /
    • pp.841-847
    • /
    • 2016
  • 네트워크 기술의 발달에 따라 고속으로 인터넷에 연결 가능한 장치의 수가 증가하면서 언제 어디서나 쉽게 접근이 가능한 클라우드 스토리지의 사용량이 증가하고 있다. 대표적인 클라우드 스토리지의 형태 중 하나인 오브젝트 스토리지는 비용이 저렴하고 높은 가용성과 지속성을 보장해주지만, HTTP 기반 인터페이스인 RESTful API로만 데이터에 접근가능하다는 제약이 있다. 본 논문에서는 이러한 점을 해소하고자, 기존 POSIX 인터페이스를 지원하며 클라우드 오브젝트 스토리지와 데이터를 주고받을 수 있는 인메모리 파일 시스템을 제안한다. 특히 본 연구의 클라우드 스토리지로 파일을 보내는 플러시 기법은 리눅스 시스템의 스왑 모듈을 활용하여 개발함으로써 기존 애플리케이션들과 높은 호환성을 가지며, 기존 클라우드 스토리지를 사용하는 시스템이 가지는 오버헤드를 최소화하였다. 제안하는 파일 시스템은 S3QL 보다는 약 57% 빠른 쓰기 성능을 보이며, tmpfs와 매우 근접한 읽기 성능을 보인다.

독립형 태양광 발전소의 연 축전지 모니터링장치 개발 (A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems)

  • 문채주;김태곤;장영학;김의선;임정민
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.

Performance Improvement Using Iterative Two-Dimensional Soft Output Viterbi Algorithm Associated with Noise Filter for Holographic Data Storage Systems

  • 누엔딘지;이재진
    • 한국통신학회논문지
    • /
    • 제39A권3호
    • /
    • pp.121-126
    • /
    • 2014
  • Demand of the data storage becomes more and more growing. This requests the next generation of storage devices to have the dominated storage capability associated with superfast read/write rate. Holographic data storage (HDS) is investigated for a long time and is considered to be a candidate for the future storage system. However, it has two-dimensional intersymbol interference that conventional one-dimensional detection solutions have not yet handled strictly because of the complexity level of system as well as the cost. We propose a new scheme that combines iterative soft output Viterbi algorithm with noise filter for improving the bit error rate performance of HDS.

슬래브축열 공조시스템의 축열성능에 관한 실험적 연구 (An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토 (Consideration of Appropriate Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage in an Office Building by Use of Measurement Value)

  • 정재훈
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.719-726
    • /
    • 2010
  • In this paper, the appropriate thermal storage time of an air-conditioning system with slab thermal storage was considered by use of summer measurement values. Two standards of heat extraction rate and criterion function were established as the standard that evaluates appropriateness. When heat extraction rate was a standard, zero hour and seven hours were obtained as appropriate thermal storage time, in the case of evaluation by energy consumption and running cost individually. Also, when criterion function was a standard, the difference between energy consumption and running cost was small, it was because the weight function to room air temperature deviation was much bigger than heat extraction rate.

충전층내에서 축열에 따른 열전달 (Heat Storage in a packed Bed)

  • 최정운;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제7권1호
    • /
    • pp.13-19
    • /
    • 1978
  • An experiment has been performed of find a temperature distribution of the circulating fluid in a packed bed thermal storage system when the inlet fluid temperature is constant. The thermal storage system is a specific-heat type in which the circulating fluid, hot air, exchanges heat directly with the heat storage materials, glass balls, in a heat storage bin. An empirical equation which includes two dimensionless variables $t^*\;and\;T_f^*$, is obtained. Also, heat storage efficiency and heat storage capacity are calculated from this equation, The heat transfer coefficient calculated by the suggested equation was compared with the value determined by the existing empirical equation.

  • PDF

EPICS를 이용한 가속기 RF 제어시스템 개발 (EPICS Based RF Control System for PAL Storage Ring)

  • 윤종철;박홍집;이진원;최진혁;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2239-2241
    • /
    • 2003
  • A new RF control system of Pohang Accelerator Laboratory (PAL) storage ring is a subsystem upgraded PAL control system, which is based upon Experimental Physics and Industrial Control System (EPICS). There are 5 control components, Low Level RF System (LRS), Klystron System, Circulator System, Cavity System, Local Cooling Water System (LCW) at the storage ring of PAL. The new RF control system for the storage ring has been under development for one years, first versions of individual VME (Versa Module Europa) Input/output modules under construction and system integration begun. In this system, VMEbus-based hardware is widely used for front-end controllers (FDS), Input/output controller (IOC). A number of Programmable Logic Controller (PLC) and SUN workstations are also used for Operator Interfaces (OPI) in the control system. This paper describes the development VME I/O module to the new control system and how the design of this new system.

  • PDF

Blockchain-based Data Storage Security Architecture for e-Health Care Systems: A Case of Government of Tanzania Hospital Management Information System

  • Mnyawi, Richard;Kombe, Cleverence;Sam, Anael;Nyambo, Devotha
    • International Journal of Computer Science & Network Security
    • /
    • 제22권3호
    • /
    • pp.364-374
    • /
    • 2022
  • Health information systems (HIS) are facing security challenges on data privacy and confidentiality. These challenges are based on centralized system architecture creating a target for malicious attacks. Blockchain technology has emerged as a trending technology with the potential to improve data security. Despite the effectiveness of this technology, still HIS are suffering from a lack of data privacy and confidentiality. This paper presents a blockchain-based data storage security architecture integrated with an e-Health care system to improve its security. The study employed a qualitative research method where data were collected using interviews and document analysis. Execute-order-validate Fabric's storage security architecture was implemented through private data collection, which is the combination of the actual private data stored in a private state, and a hash of that private data to guarantee data privacy. The key findings of this research show that data privacy and confidentiality are attained through a private data policy. Network peers are decentralized with blockchain only for hash storage to avoid storage challenges. Cost-effectiveness is achieved through data storage within a database of a Hyperledger Fabric. The overall performance of Fabric is higher than Ethereum. Ethereum's low performance is due to its execute-validate architecture which has high computation power with transaction inconsistencies. E-Health care system administrators should be trained and engaged with blockchain architectural designs for health data storage security. Health policymakers should be aware of blockchain technology and make use of the findings. The scientific contribution of this study is based on; cost-effectiveness of secured data storage, the use of hashes of network data stored in each node, and low energy consumption of Fabric leading to high performance.