• 제목/요약/키워드: Storage Air Heater

검색결과 40건 처리시간 0.02초

히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축 (Development of Measurement and Performance Testing System for Heat Pump water Heater)

  • 권성철;양승권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

가열 공기 유입에 따른 복합형 태양열 가열기 공기-물 제조 성능에 관한 연구 (Performance Evaluation of Hybrid Solar Air-Water Heater when the Heated Air is used as Inlet Air during Air and Water is Heated Simultaneously)

  • 최휘웅;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.21-29
    • /
    • 2015
  • In this study, the performance of hybrid solar air-water heater when the heated air was used as inlet air was investigated during air and liquid were heated simultaneously. Temperature difference between inlet air and ambient was set as $0^{\circ}C$, $13^{\circ}C$ and $22^{\circ}C$ and it was maintained during the daily operation. As a result, thermal efficiency of liquid heating was increased when the inlet air temperature was increased and heat gain of the water in heat storage tank was also increased with increment of temperature difference between inlet air and ambient temperature. On the contrary to this, the decrement of air heating efficiency and total efficiency of collector was confirmed with increment of inlet air temperature and it is considered that heat gain of liquid side is lower than heat loss of air side that occurring by using heated air as inlet air of collector. So, from these results, maximum temperature that the liquid in heat storage tank can reach was expected to increase if the return air or any heated air was used as inlet air. But air and total efficiency of hybrid solar air-water is decreased, so using outdoor air as inlet air is considered as better way on perspective of using of solar thermal energy by hybrid solar collector. However, it is hard to conclude that using outdoor air is better than heated air on the perspective of energy saving of building because the performance of heat storage performance was increased even air and total thermal efficiency was decreased, so the necessity of more profound consideration about these result in further research was confirmed for putting the hybrid solar air-water heater to practical use.

태양열이용 흡수식냉동기에 의한 냉방장치 연구 (Study on the Cooling System by Solar- powered Absorption- Type Chiller)

  • 김효경;김무근;정시영
    • 대한설비공학회지:설비저널
    • /
    • 제12권3호
    • /
    • pp.147-158
    • /
    • 1983
  • This study aims at experimental investigation on the feasibility of solar cooling in the seoul area. The system is comprised of fiat plate collectors, storage tank, auxiliary heater and Li-Br absorption chiller. Characteristics of the chi lier and the solar contribution on cooling were obtained by experiment The results show that during the days of experiment('83.6.10-6.22, 8.17-8.19) space cooling could be achieved by using soiar energy and auxiliary heater Moreover, there were time intervals during the day when cooling was possible using solar energy only without the auxiliary heater.

  • PDF

초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작 (Design and Manufacture of the air mixing system for supersonic ground test facility)

  • 이양지;강상훈;양수석
    • 항공우주기술
    • /
    • 제7권1호
    • /
    • pp.40-48
    • /
    • 2008
  • 공기 혼합시스템은 초음속 지상추진시험설비의 축열식 가열기로부터 공급되는 $1000^{\circ}C$, 3.5MPa의 공기와 고압공기 공급원으로부터 공급되는 상온, 동일 압력의 공기를 혼합시켜서 시험부로 공급하기 위한 설비로 32MPa로 압축되어 있는 고압공기 공급원을 3.5MPa로 감압하는 고압/저온 유동제어부, 축열식 가열기의 고온밸브에서부터 공기 혼합기로 고온의 공기를 공급하기 위한 고온 배관, 축열식 가열기로부터 공급되는 고온 유동과 고압공기 공급원으로부터 공급되는 상온 유동을 혼합하기 위한 공기 혼합기로 구성된다. 공기 혼합 시스템을 통하여 완전히 혼합된 공기의 유량은 25kg/s, 온도는 약 $400^{\circ}C$로 이를 통하여 초음속 지상추진시험설비의 구동 영역을 저 마하수, 저 고도 영역까지 확장할 수 있다.

  • PDF

곡물빈용 공기조화장치의 퍼지제어기 개발 (Development of Fuzzy Controller for Air Conditioning of Grain Bin)

  • 최영수;문대식;정종훈
    • 한국식품저장유통학회지
    • /
    • 제9권2호
    • /
    • pp.137-143
    • /
    • 2002
  • Temperature and humidity are the most important factors and should be effectively controlled for the cold storage of graius. Fuzzy logic can be easily implemented to the MIMO(Multi-Input Multi-Output) control systems. For the cold storage in grain bin, fuzzy logic was applied to an air conditioning system. The capacities of the grain bin and the air conditioner are 80 tons and 30㎾, respectively. Also, the target values of temperature and relative humidity in outlet duct of the air conditioner were 8$\^{C}$ and 75%, respectively. In order to control temperature and relative humidity of air, a damper in inlet duct was manipulated for temperature control and a heater was used for humidity control. Temperature deviation and change of temperature deviation were used as input parameters for the fuzzy system. Humidity was only considered as a load. The experimental results showed that the controlled temperature of exhausted air was maintained at 8$\pm$2$\^{C}$. Relative humidity of the air was also controlled at the target relative humidity of 50∼80%.

Packed Bed 태양에너지 저장시스템의 열성능에 관한 수학적 시뮬레이션 (Mathematical Simulation on Thermal Performance of Packed Bed Solar Energy Storage System)

  • 아닐쿠마르;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.331-338
    • /
    • 2015
  • Solar air heaters (SAHs) are simple in design and widely used for solar energy collection devices, and a packed bed is one of typical solar energy storage systems of thermal energy captured by SAHs. This paper presents mathematical modeling and simulation on the thermal performance of various packed bed energy storage systems. A MATLAB program is used to estimate the thermal efficiency of packed bed SAH. Among the various packed bed energy storage systems considered, the wire mesh screen packed bed SAH shows the best thermal efficiency over the entire range of design conditions. The maximum of thermal efficiency of packed bed SAH with wire mesh screen matrices has been found to be 0.794 for Re=2000 - 20000 and ${\Delta}T/I=0.002-0.02$.

병원 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Hospital Building)

  • 최영돈;한성호;조성환;김두성;엄철준
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.275-282
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large hospital building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

공기순환구조를 갖는 축열지붕의 열전달해석 (Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System)

  • 신우철;박석현;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building)

  • 최영돈;한성호;조성환;김두성;엄철준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

R141b 포접화합물을 이용한 축냉시스템의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cool Storage System using R141b Clathrate)

  • 정인성;김양규;이준식;노승탁
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.354-364
    • /
    • 1994
  • Experiments have carried out to investigate the effects of parameters, such as mass ratio of R141b-to-water, stirrer speed, brine inlet temperature, brine flowrate, and additives, on the performance of the cool storage system using R141b clathrate. The cool storage system in this experiment was composed of storage tank, refrigerator, and heater. The results show that the mass ratio of R141b-to-water, 1 : 3~1 : 3.5 gives the best performance and the stirring speed has optimum point as 600rpm. At this speed impeller Reynolds number is $1.01{\times}10^5$. The lower the inlet brine temperature and the highter the brine flowrate, the better performance. The addition of metal powder turned out to reduce the degree of supercooling. The supercooling reduction was proportional to the amount of the metal power. However when metal powder was added more than 0.1 wt%, there was no additional supercooling reduction. The surfactants shortened the time consumed for cool storage to the half of no surfactant added case.

  • PDF