• 제목/요약/키워드: Stopwatch

검색결과 27건 처리시간 0.024초

경량식혈기를 이용한 용기묘 식재의 작업공정 및 초기생장 분석 (An Analysis on the Operation Productivity and Initial Growth of Containerized Seedlings Planted by the Lightweight Planting Auger)

  • 고치웅;김동현;이관희;김진현;김동근
    • 한국환경복원기술학회지
    • /
    • 제19권6호
    • /
    • pp.77-86
    • /
    • 2016
  • Due to aging of the rural and mountain populations the labor force is reduced. However work intensity continues to increase, thus, there is a need to improve the current effectiveness of forest operations. This study compared and analyzed the Operation productivity and efficiency of planting containerized seedlings using a battery-powered planting auger and a mattock. Growth was also investigated by looking into the initial growth increments in the planted seedlings. Tasks were investigated by analyzing the process and operation time needed to plant 1 containerized seedling using a planting auger and a mattock. The time spent on the various elements of the planting process was measured with a stopwatch but observations were done continuously. Result of the study shows that with the use of a lightweight planting auger the average time spent to plant a containerized seedling is 18.61 seconds while with the use of a mattock it took an average of 26.96 seconds which clearly demonstrates that the planting auger is more efficient in terms of working hours. Working intensity was also analyzed with the use of a portable heart rate monitor (Polar V800). The average increase in heart rate and work intensity index were analyzed for one planting cycle. It was observed that when using the lightweight planting auger, there was a 46.51% increase in the average heart rate while a 74.67% increase in heart rate when the mattock was used which shows that there is a significant increase in heart rate when mattock is used. In addition, work intensity index was observed to be 29.95% and 47.83% when the planting auger and mattock were used respectively. With the continuous use, work intensity index is significantly higher with the use of the mattock as compared to that of the lightweight planting auger. There were no significant differences on the growth increment of seedlings planted using the different tools until a year after planting, however differences in growth increment were observed after a year. A difference of 15.1 cm in height and 3.41 mm in diameter was observed which shows that the use of lightweight planting auger is excellent for planting containerized seedlings.

입원한 영유아의 심첨 맥박 측정 방법에 관한 연구 (The Study for Apical Pulse Measurement Technique Through Hospitalized Children)

  • 조경미;김은주
    • Child Health Nursing Research
    • /
    • 제5권1호
    • /
    • pp.48-58
    • /
    • 1999
  • The purpose of this study was to determine the most accurate technique measuring the apical pulse rate, using three counting duration 15, 30 and 60 seconds, and two methods start ‘0’ and start ‘1’. The instrument used in the study was the EKG monitor, stethoscope and stopwatch. Data was analyzed by utilizing SPSSWIN program. General characteristics of the subjects were analyzed by frequency, percentile, mean, SD. The subject of this research is made up of 46 children and 20 nurses. The children were infants, & under the age of 5. They were hospitalised in PICU & NICU in 2 tertiary hospitals in seoul from Jan. 1. 1998 to Sep. 10. 1998. The measurement of starting 1 & measurement of starting ‘0’ used the T-test to find out the measurement error. Apical pulse duration of 15, 30, 60 seconds were used to find out measurement error, the measurement error depend on experience of Nurse were analyzed by using ANOVA. The result of this study are as follows. 1. When comparing the starting poin of apical pulse 0&1, starting with 1 the measurement error is less, but not statiscally significant. 2. When counting the apical pulse by 15, 30,60 sec. ; 60 seconds counting duration was more accurate, but not statistically significant. 3. The mean of measure error ; Group under 100/min, is 10.33 ; from 100 re 119/min, is 8.30 ; from 120 to 139/min, is 4.76 ; from 140 to 159/min, is 6.09 ; above 160, is 17.83. The differences of these groups are statistically significant. When 60sec were counted, under 140/min the mean of measurement error is 3.4. Also when 30 seconds were counted from 140/min to 159/min the measurement error is 7.14, above 160/min the measurement error is 16.4. That measurement mean is the smallest than the other durations. During the 15 sec. count the measurement error was the largest of them all. 4. By the experience of the nurses, the apical pulse count measurement error was discovered. Under a year experience this measurement error was the largest(11.09), 1 year to under 3 years, the error is the smallest(4.86). 3 year to under 6 years the error is 8.33, 5 years above the error is 6.11 but this is not statistical significant. Under a year experience when counting 15, 30, 60 seconds the error is the largest. The group of the nurses from a year to under 3 years, the measurement error is the smallest of all the groups. The result of the study is to determine the technique measuring the apical pulse rate, Hargest (1974), starting point ‘0’ is not proved. When the pulse rate increases the 30 sec measurement rate is accurate. Under 140/min the 60 sec measurement rate is the most accurate. Depending on the nurses experiences, there is a variable difference to the apical pulse rate measurement. Especially new nurses training courses should enforce the children’s pulse rate count and the basic vital signs.

  • PDF

수술후 급성 동통에 대한 Tramadol/Acetaminophen과 Codeine/Acetaminophen/Ibuprofen의 효과 발현시점과 진통효과의 비교 (COMPARISON OF TRAMADOL/ACETAMINOPHEN AND CODEINE/ACETAMINOPHEN/IBUPROFEN IN ONSET OF ANALGESIA AND ANALGESIC EFFICACY FOR POSTOPERATIVE ACUTE PAIN)

  • 정영수;김동기;김문기;김형준;차인호;한무영;이의웅
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권2호
    • /
    • pp.143-149
    • /
    • 2004
  • Background: Some clinical trials have reported that a new analgesic combination of tramadol and acetaminophen provides good efficacy in various pain models. For the more clinical uses of this agent, comparisons about the onset of analgesia and analgesic efficacy in the acute state of pain with the other drugs known as strong analgesics were needed. Purpose: The goal of this study was to compare the times to onset of analgesia and the other analgesic efficacy of 75 mg tramadol/650 mg acetaminophen and 20 mg codeine/500 mg acetaminophen/400 mg ibuprofen in the treatment of acute pain after oral surgery. Patients and Methods: Using a randomized, single-dose, parallel-group, single-center, and active-controlled test design, this clinical study compared the times to onset of analgesia using a two-stopwatch technique and the other analgesic efficacy of the single-dose tramadol/acetaminophen and codeine/acetaminophen/ibuprofen. These were assessed in 128 healthy subjects with pain from oral surgical procedures involving extraction of one or more impacted third molars requiring bone removal. From the time of pain development, the times to onset of perceptible and meaningful pain relief, pain intensity, pain relief, an overall assessment, and adverse events of the study medications were recorded for 6 hours. Results: The demographic distribution and baseline pain data in the two groups were statistically similar. The median times to onset of perceptible pain relief were 21.0 and 24.4 minutes in the tramadol/acetaminophen and codeine/acetaminophen/ibuprofen groups respectively and those to onset of meaningful pain relief were 56.4 and 57.3 minutes, which were statistically similar. The other efficacy variables such as mean total pain relief (TOTPAR) and the sum of pain intensity differences (SPID) were also similar in the early period after pain development and drug dosing. The safety of tramadol/acetaminophen was well tolerated and very comparable to that of codeine/acetaminophen/ibuprofen. Conclusions: In this acute dental pain model, the onset of analgesia and analgesic efficacy of tramadol/acetaminophen was comparable to that of codeine/acetaminophen/ibuprofen. These results showed that tramadol/acetaminophen was recommendable for fast and effective treatment in the management of postoperative acute pain.

노인보호구역 보행자녹색시간 산정을 위한 보행속도 기준 개선 (Improvement of Pedestrian Speed Criteria for the Pedestrian Green Interval at Silver Zone)

  • 한음;조혜림;문성철;윤성범;박순용
    • 한국ITS학회 논문지
    • /
    • 제19권4호
    • /
    • pp.45-54
    • /
    • 2020
  • 본 연구는 고령자에 대한 보행속도 및 인지-반응을 포함한 보행특성에 관한 기초자료를 조사하였으며, 이를 토대로 보행 신호시간을 산정하였다. 현장조사는 스탑워치를 이용하여 보행자의 실제 횡단시간을 조사하였고, 구두조사로 연령을 조사하여 일반인과 고령자그룹으로 구분하였다. 자료를 분석한 결과 일반인의 평균보행속도는 1.29m/s, 노인은 1.13m/s로 일반지역의 기준인 1.0m/s 보다 높게 나타났다. 또한 하위 15th percentile속도를 살펴보면 일반인은 1.01m/s, 노인은 0.85m/s로 분석되어 노인의 경우 일반지역 기준보다 낮은 보행속도를 가지며 보호구역 기준인 0.8m/s 보다는 높은 속도가 나타났다. 하지만 지팡이나 휠체어를 사용하는 노인의 경우 하위 15th percentile속도가 0.73m/s로 나타나 현재 보호구역 기준보다 낮은 보행속도를 가진 것으로 분석되었다. 본 연구결과는 향후 노인의 보행환경을 개선하는데 적용할 수 있고, 장기적으로는 교통약자의 이동성 증진에 기여할 것으로 판단된다.

측두하악장애 의료행위분류에 관한 연구 (The Development of Classification System of Dental Services for Temporomandibular Joint Disorders)

  • 송윤헌;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제30권2호
    • /
    • pp.257-268
    • /
    • 2005
  • 우리나라 건강보험제도는 보수지불방식에서 전체적으로 보면 행위별수가제(fee for service)를 유지하고 있다. 이 제도에서는 진료수가의 설계에서 각 의료서비스의 단위를 설정하기 위해서는 현재 임상에서 이루어지고 있는 모든 의료행위에 대한 목록이 필요하게 된다. 따라서 본 연구에서는 측두하악장애 의료의 수가구조와 수가항목에 대해 재분류를 통한 체계화과정을 통해서 향후 투입자원에 기초한 상대가치를 산정하여 수가수준을 결정할 수 있는 준거를 제시하고자 하였다. 현행 행위별 수가제도의 범위내에서 측두하악장애 진료행위에 대한 델파이법을 이용하여 의료행위에 대한 재분류하여 항목화 작업을 거치면서 자원기준 상대가치 산출모델의 선행연구를 시행하였다. 이를 통해 의료행위분류에서는 총 151개의 의료 행위를 규명하였다. 이를 건강보험 수가항목이 되도록 하기 위해서는 지속적인 정련화 과정이 필요하게 되므로 용어의 정리 및 통일, 명확한 진료범위의 설명, 체계적인 분류구조 등이 고려되어야 한다. 이상의 연구결과는 향후 치과의료의 구조적 문제점과 현안과제를 해결하는 기초자료로 활용하고, 앞으로 치과의료의 수가 수준을 결정하는 후속연구의 방향설정과 참고자료로 활용하며, 의료수가체계의 표준화를 유도하여 의료이용의 편의성을 도모하고 의료정책에 대한 국민적 신뢰를 회복하여 측두하악관절장애 진료의 건강보험 확대적용 및 향후 민간 사보험 도입시 기초자료로 활용될 것으로 사료된다.

아레나 시뮬레이션을 활용한 화장품 포장공정의 개선사례 연구 (A Study on the Improvement Case of Cosmetic Packaging Process Using ARENA Simulation)

  • 이남수;이재용;조은현;이동형
    • 산업경영시스템학회지
    • /
    • 제43권2호
    • /
    • pp.72-78
    • /
    • 2020
  • Demand for cosmetics with functionality and eco-friendliness has increased dramatically due to recent aging, well-being trends, and increased interest in beauty. Cosmetics production in 2014 was 8,970.4 billion won, an increase of about 50% compared to 6,014.6 billion won in 2010. In the midst of this, similar companies in intense competition are pursuing differentiated strategies and innovation activities to solve quality, price and delivery problems. In particular, cosmetics packaging work is getting more difficult due to the increasing bill of materials (BOM) and difficult assembly methods. Therefore, in this study, the following problems were identified and suggestions for the improvement of the packaging Many research laboratories such as biotechnology, chemistry, and pharmaceuticals, which are undergoing various studies, are equipped with ready-made laboratory safety equipments such as bio-safety workbenches, aseptic bases, and exhaust workbenches. However, most researchers are disadvantaged in using existing safety equipment. This is because existing safety equipment can not take into account all of the unique characteristics of the research. For this reason, researchers are demanding the development of customized safety equipment that is well suited to their research needs. process of Company C, which is facing difficult situation to respond to the customer 's delivery due to the 52 - hour work week. First, we used the stopwatch to find the difficulty process in the packaging process and show ways to improve it. Second, to improve the efficiency of line balancing in the packaging process, we integrate processes, improve work methods, and perform simple automation. As a result, the prepare loss for replacement was reduced by 1 minute from 5 minutes, resulting in a 23% increase in productivity from 112 ea./hour to 137ea./ hour per person. At this time, the LOB of the packaging process was improved from 70% to 82% by operating one more production line through one person per line, total 9 people saving.

유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화 (The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography)

  • 이다영;남궁혁;조석원;오신현;임한상;김재삼;이창호;박훈희
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.62-67
    • /
    • 2012
  • 유방암 환자의 감시림프절 생검을 위하여 현재 방사성동위원소와 blue dye를 이용한 감시림프절 매핑(Mapping)이 선행되고 있다. 현재 모든 환자에 대하여 일괄적인 검사방법이 적용되므로 환자의 유방의 크기나 비만도와 같은 특성이 고려되지 않아 림프절의 흐름이 느린 환자의 경우, 림프절을 충분히 형성하지 못한 채 검사가 종료되는 경우가 종종 발생한다. 본 연구에서는 환자의 신체적 특성인 체질량지수와 유방의 크기에 따른 림프액의 속도차이를 관찰하였다. 이를 통해 방사성동위원소를 이용한 유방의 감시림프절 신티그래피 에서 환자의 특성을 고려한 최적의 검사시간을 도출하는데 목적을 두었다. 본 연구는 2011년 10월부터 2011년 12월까지 수술직전 유방의 감시림프절 신티그래피를 시행한 100명(여성 100명, 평균연령 $50.34{\pm}10.26$)를 대상으로 하였다. 장비는 감마카메라 Forte (Philips Medical Systems, Nederland B.V.)를 사용하였으며, 방사성의약품은 $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml를 피내주사하였다. 먼저 80명의 환자를 대상으로 기존의 5분 검사방법대신 충분히 림프절을 형성할 때까지 시간의 제한 없이 영상을 획득하였다. 이를 통해 환자의 유방크기와 체질량지수 별 그룹을 나누어 평균 검사시간을 구하였다. 이 결과를 바탕으로 검사시간을 변화시킨 변형 유방 림프신티그래피를 20명의 환자에게 시행하여 유용성을 확인하였다. 80명의 대상 중 유방의 크기에 따른 평균 검사시간은 A그룹 2.48분, B그룹 7.69분, C그룹 10.43분이었다. 80명의 대상 중 체질량지수에 따른 평균 검사시간은 저 체중 1.35분, 표준 2.56분, 과 체중 5.62분, 비만 15분이었다. 앞서 얻어진 정보를 바탕으로 각 그룹별 적절한 검사시간을 적용하여 검사를 시행하였다. 결과는 20명 중 성공평가를 받은 경우는 17회 실패평가를 받은 경우는 3회로 총 85% 성공률을 나타내었다. 유방의 크기와 체질량지수에 따른 총 검사 시간은 체질량지수가 높을수록, 유방의 크기가 클수록 증가하였으며, 얻어진 정보를 바탕으로 기존 검사방법에서 검사시간만을 변화시킨 변형 유방 림프신티그래피를 적용하였을 때 대부분의 경우 검사시간 내 림프절을 형성할 수 있었다. 이를 통해 모든 환자에게 일괄적으로 적용하던 검사방법보다 개인의 신체적 특성을 고려한 적절한 검사시간을 각각 다르게 적용하였을 때 검사에서 높은 성공률을 보임을 알 수 있었다.

  • PDF