• Title/Summary/Keyword: Stokes pulse

Search Result 18, Processing Time 0.029 seconds

Peak Power Reflectivity and Phase Conjugation Fidelity in a Pulse Compression Process by Stimulated Brillouin Scattering (유도 브릴루앙 산란에 의한 펄스 압축 과정에서의 Peak Power 반사율과 위상공액도)

  • 조민식;최병일;남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.37-44
    • /
    • 1994
  • The characteristics of stimulated Brillouin scattering wave for applications to high power laser was experimentally investigated. The peak power reflectivity and the phase conjugation fidelity of Stokes wave with respect to the focal length of lens were measured, and the phase conjugation fidelity for a compressed part of the Stokes wave was also investigated. For the long focal length of lens.(f=100 cm), the peak power of the Stokes wave amounts to about twice as high as that of incident wave. The phase conjugation fidelity for the compressed leading pulse is up to 90%, better than that for other temporal parts of the Stokes pulse. In spatial distribution, the Stokes pulse from the axial region has the largest SBS gain, and it has been ascertained as a best candidate to the application due to excellent pulse compression, peak power reflectivity, and good phase conjugation fidelity.

  • PDF

Theoretical Study of Brillouin OTDA using Two Pulse Insets (두 대의 펄스 레이저를 사용한 Brillouin OTDA의 이론적 분석)

  • Hong, Yong-Hyun;Lee, Ho-Joon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.3
    • /
    • pp.196-201
    • /
    • 2007
  • A theoretical study of Brillouin optical time domain analysis (BOTDA) using two pulse lasers is performed. Even though a point detection is made for a pump pulse period, the dynamic range of BOTDA using two pulse lasers is approximately 5 dB more than that of a pulse and a CW laser when the fiber length is 140 km and the Stokes power is 1 mW.

Analysis for the Pulse-Jet Cleaning Flow of a Hot Gas Ceramic-Filter Element (고온고압 세라믹 여과재 탈진 과정의 유동 해석)

  • Park I. W.;Ryu J. H.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.110-115
    • /
    • 1998
  • An axisymmetric Navier-Stokes procedure has been developed to analyze the pulse jet flow in a ceramic filter unit for the dust dislodging process. Using Baldwin-Lomax turbulence model as a closure relationship, the SIAF(Scalar Implicit Approximate Factorization) algorithm together with the ${\delta}^k-Correction$ iterative time marching scheme is adopted to solve the unsteady compressible Navier-Stokes equations. After some validation tests, the code has been applied to solve the pulse jet flow and examine the effects of geometry and reservoir pressure condition on the pressure level inside the filter unit. To avoid dealing with the uncertainty of such factors as the cohesion of the collected dust and the adhesion of the dust to the medium and also to simplify the analysis, the filter wall is assumed to be impermeable. The results for various test cases are presented.

  • PDF

Waveform distortion of the stimulated Brillouin scattering in a single mode optical fiber with Q-switched Nd:YAG laser

  • Lee, Sang-Hun;Cho, Jin-Hang;Kim, Chil-Min
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.335-336
    • /
    • 2008
  • We observe the distortion of the back scattered Stokes pulse and the complementary distortion of the transmitted pulse by the stimulated Brillouin scattering when a Q-switched Nd:YAG laser pulse injected into a single mode optical fiber. We determine the constant required energy for the SBS by comparing their temporal shapes.

  • PDF

Evolution of stokes pulses of stimulated Raman scattering in a CeO$_2$-doped multimode fiber (GeO$_2$ 첨가 다중모드 광파이버에서 유도라만산란에 의한 스토크스 펄스 발생)

  • Yi, Yong-Woo;Hwang, In-Duck
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1095-1099
    • /
    • 2002
  • We experimentally investigate the evolution of nanosecond Stokes pulses in a single-pass Raman laser pumped by a Q-switched Nd:YAG laser at 1064 na As a Raman medium, a GeO2-doped graded-index multimode fiber ot 220 m long Is used. We demonstrate that efficient generation of several Stokes components with 1.5∼2.7 nanosecond pulsewidth is obtained by varying the input pump energy.

Evolution of stokes pulses of stimulated Raman scattering in a Ge$O_2$-doped multimode fiber (Ge$O_2$-doped 다중모드 파이버에서 유도라만산한의 스토크스 펄스의 발생)

  • Yi, Yong-Woo;Hwang, In-Duk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.529-532
    • /
    • 2002
  • We experimentally investigate the evolution of nanosecond Stokes pulses in a single-pass Raman laser pumped by a Q-switched Nd: YAG laser at 1064 nm. As a Raman medium, a GeO$_2$-doped graded-index multimode fiber of 220m long is used. We demonstrate that efficient generation of several Stokes components with 1.5-2.7 nanosecond pulsewidth is obtained by varying the input pump energy.

  • PDF

A Numerical Analysis of Pulse-Jet Cleaning Characteristics for Ceramic Filter System Design (세라믹필터 집진장치의 역세정 시스템 설계를 위한 유동해석)

  • 정재화;서석빈;김시문;안달홍;김종진
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.197-206
    • /
    • 2003
  • A numerical analysis of the pulse-jet cleaning characteristics in a porous ceramic candle filter system was performed. To obtain the detailed velocity and pressure distribution during the cleaning process in a porous filter system, the axi-symmetric compressible Navier-Stokes equations including energy conservation equation were solved by using the FLUENT code which adopts FVM (Finite Volume Method). The effects of pulse cleaning nozzle diameter, nozzle tip position, permeability of a porous ceramic candle filter, diffuser throat diameter, and cleaning pressure on the cleaning flow characteristics were investigated extensively.

Transient Impedance Characteristics of Grounding Rods (봉상접지극의 과도임피던스 특성)

  • 김일권;김점식;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

Numerical Investigation on detonation combustion waves of hydrogen-air mixture in pulse detonation combustor with blockage

  • Pinku Debnath;K.M. Pandey
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.3
    • /
    • pp.203-222
    • /
    • 2023
  • The detonation combustion is a supersonic combustion process follows on shock wave oscillations in detonation tube. In this paper numerical studies are carried out combined effect of blockage ratio and spacing of obstacle on detonation wave propagation of hydrogen-air mixture in pulse detonation combustor. The deflagration to detonation transition of stoichiometric (ϕ=1)fuel-air mixture in channel has been analyzed for effect of blockage ratio (BR)=0.39, 0.51, 0.59, 0.71 with spacing of 2D and 3D. The reactive Navier-Stokes equation is used to solve the detonation wave propagation mechanism in Ansys Fluent platform. The result shows that fully developed detonation wave initiation regime is observed near smaller vortex generator ratio of BR=0.39 inside the combustor. The turbulent rate of reaction has also a great significance role for shock wave structure. However, vortices of rapid detonation wave are appears near thin boundary layer of each obstacle. Finally, detonation combustor demonstrates the superiority of pressure gain combustor with turbulent rate of reaction of 0.6 kg mol/m3 -s inside the detonation tube with obstacle spacing of 12 cm, this blockage enhanced the turbulence intensity and propulsive thrust. The successful detonation wave propagation speed is achieved in shortest possible time of 0.031s with a significance magnitude of 2349 m/s, which is higher than Chapman-Jouguet (C-J) velocity of 1848 m/s. Furthermore, stronger propulsive thrust force of 36.82 N is generated in pulse time of 0.031s.

Complicated Wound Infection Following Transvenous Endocardial Pacemaker (경정맥(經靜脈) 내적(內的) Pacemaker 이식후(移植後) 발생(發生)한 복잡한 감염합병증(感染合?症)의 1치험례(治驗例))

  • Lee, D.Y.;Yoon, Y.J.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.265-270
    • /
    • 1976
  • Implantation of a permanent pacemaker is a widely accepted procedure for the patient with complete heart block.As a result of these device, the prognosis for patients with Adams-Stokes syndrome caused by complete A-V block and other cardiac arrhythmia have become much more optimistic. Permanent pacemaker implantation by means of a transvenous approach has made the operative risk much less and the procedure simpler. However, a number of complications have been reported in the literature regarding transvenous endocardial pacemaker implantation during the last a decade. The patient presented in this paper is a 26-year old girl who was implanted with a permanent pacemaker at 14 years of age because of a congenital A-V block. Following first exchange of pulse generator, the electrode (lead) was fractured, so that by the pulse generator, a change to the transvenous technique of implantation was made, After this, there were episodes of recurrent wound infection on three occasions, even though the site of pulse generator implantation was exchanged to the contralateral side of chest wall, massive doses of antibiotics were administered and sensitivity tests for coagulase positive staphylococcal infection were performed. Though there was no definite evidence of blood stream infection by blood culture, we decided not to use the transvenous technique and not to implant the pulse generator in the chest wall because the venous system and the entire anterior chest wall appeared to be diseased or contaminated by virulent pyogenic organisms. Finally this intractable systemic and local wound infection was successfully controlled by myocardial lead implantation via a subxiphoid approach and implantation of the pulse generator far down in the abdominal wall. The causes and routes of recurrent wound infection and possible blood born infection in this particular patient are still obscure. We strongly believe that myocardial pacemaker implantation is much safer than transvenous endocardial pacemaker implantation & myocardial pacemaker implantation is a definite method for controlling such an intractable wound infection. following transvenous pacemaker implantation.

  • PDF