• 제목/요약/키워드: Stirling 냉동기

검색결과 46건 처리시간 0.032초

스터링 냉동기의 주파수 특성에 의한 성능평가에 관한 연구 (A Performance test of Stirling Cryocooler by Frequency Characteristics)

  • 박성제;홍용주;김효봉;고득용;오군섭;김종학
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.25-32
    • /
    • 2000
  • A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. The FPFD Stirling cryocooler employs 1) the Stirling cycle for refrigeration, 2) linear for driving the cryocooler, 3) spring and gas support systems, and 4) fine gap for clearance seals. It is the most suitable design for a mechanical cryocooler utilized in night vision environment. In order to get optimum operating frequency, natural frequency of piston and displacer, optimum phase angle between piston and displacer, cooling capacity, performance tests of the Stirling cryocooler by the frequency characteristics were performed.

  • PDF

실제기체의 물성을 이용한 Stirling 냉동기 단열해석 (Adiabatic Analysis of Stirling Refrigerator with Real Gas Properties)

  • 백종훈;장호명
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.150-160
    • /
    • 1995
  • A Finkelstein adiabatic analysis is performed for Stirling refrigerator with real gas properties of helium. The mass balance and the energy balance equations are formulated into the form that is convenient for incorporating an available computer code of the helium properties. The differential equations are solved numerically. The calculated coefficient of performance(COP) and the pressure variation are compared with the results obtained when helium is assumed to be an ideal gas. The relative errors in COP are presented as functions of the refrigeration temperature and the maximum cycle pressure.

  • PDF

수소액화 예냉용 소형 스털링 극저온 냉동기 특성 연구 (A Study on Stirling Cryocooler for Precooling Hydrogen Liquefier)

  • 박성제;고준석;홍용주;김효봉;염한길;인세환
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.651-659
    • /
    • 2016
  • Korea Institute of Machinery & Materials (KIMM) has developed a high efficient Stirling cryocooler with moving magnet linear compressor for precooling hydrogen liquefier and cooling high temperature superconductor (HTS) devices, such as superconductor cable and superconductor fault current limiters. Hydrogen liquefier and HTS electric devices require cryocooler with cooling capacity of hundred watts to kilowatts at 77 K. The compressor in the Stirling cryocooler uses opposed moving magnet linear motors to drive opposed pistons. High efficient Stirling cryocooler is designed by SAGE-software, manufactured and tested systematically. A cooling capacity of 1 kW at 77 K with an electric input power of 9.6 kW has been analyzed. But prototype test results of the Stirling cryocooler have the cooling capacity of 0.65 kW at 76.8 K with an electric input power of 8.1 kW. And then, 21.5% Carnot COP (Coefficient of performance) of the prototype Stirling cryocooler is achieved. The comparison analysis between SAGE-model and experimental results has shown the direction for further design optimization of the Stirling cryocooler.

동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구 (A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF

적외선 센서 냉각용 스터링 냉동기의 실험적 연구 (Experimental Study on the Stirling refrigerator for Cooling of Infrared Detector)

  • 박성제;홍용주;김효봉;고득용;김종학;유병건
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.172-176
    • /
    • 2001
  • A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). In order to evaluate the feasibility of using a linear motor driving cryocooler, prototype Stirling cryocooler with a nominal cooling capacity of 0.5W at 80K was designed, fabricated and tested. The prototype has achieved no load temperature of 51K and cooling power of 0.33W.

  • PDF

적외선 센서 냉각용 스터링 냉동기의 성능시험 (Performance Test of the Stirling Cryocooler for Cooling of the Infrared Detectors)

  • 고득용;박성제;김효봉;염한길;김홍국;김남환
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.202-206
    • /
    • 1999
  • This paper presents operating process of the Stirling cryocooler and results obtained with the performance test for Signal Usfa UP 7075 Stirling cryocooler. An experimental study was carried out to develop the more reliable Stirling cryocooler. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the Stirling cryocooler wa 62.5K and the cooling capacity at the optimum operating condition was 0.4W at 77K. At that time, carnot COP was 0.024.

  • PDF

극저온 스터링 냉동기용 선형 압축기 개발 (A development of linear compressor for a cryogenic stirling cooler)

  • 지상우;임경화;강희석;강경태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.731-734
    • /
    • 2001
  • A cryogenic stirling cooler is currently under development at Korea Institute of Industrial Technology(KITECH). Cryocooler has many kinds of types. The stirling cooler is the most appropriate one for under 80K with the trait of long life cycle and small size. The stirling cooler uses helium as a working fluid. Helium is pressurized by the linear compressor which is driver by linear motor. In this paper, the change of pressure and volume is studied by the isothermal analysis method. It is necessary to investigate the optimized pressure to meets the highest COP. The compressor's piston and expender's displacer interact according to the working fluid's pressure level and the phase difference. This paper presents the relation between the initial pressure and the work of cryocooler. By that results, we can predict the performance of linear compressor.

  • PDF

Split tube 길이변화에 따른 스터링 극저온 냉동기의 특성에 관한 연구 (Study of Stirling Cryocooler Performance with different length of split tube)

  • 홍용주;박성제;고득용;김효봉;오군섭;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, performance tests of stirling cryocooler with different length of split tube were performed to get characteristics of cryocooler. The Experimental results show the Stirling cryocooler with small volume of split tube has higher cooling power and faster response time.

  • PDF

Linear compressor 스터링 냉동기 설계에 관한 연구 (Design of the Linear Compressor Stirling Cryocooler)

  • 박성제;고득용;홍용주;김효봉
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.81-84
    • /
    • 2000
  • This paper presents operating process and design method on the linear compressor Stirling cryocooler for cooling infrared detector. The free piston-type Stirling cryocooler, which applies 1) the Stirling cycle for refrigeration, 2) linear motors for driving, 3) flexure bearings for support systems, and 4) fine gap for clearance seals, is the most suitable design for a mechanical cryocooler utilized in a night vision environment.

  • PDF

회전압축기형 스털링 냉동기의 열환경 성능시험에 관한 연구 (A Study on Thermal Environmental Performance Test of the Rotary Compressor Stirling Cryocooler)

  • 박성제;홍용주;김효봉;김대웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1953-1958
    • /
    • 2007
  • This paper presents the results of a series of performance tests for the integral Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Integral Stirling cryocooler for thermal imaging system have matured to the stage of undergoing formal qualification test program. The thermal environmental test of the Stirling cryocooler is presented in this paper. We performed that low and high temperature keeping test from $-40^{\circ}C$ to $+71^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooldown time to 80K and steady state input power at 80K were determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooldown time to 80K of less than 5 minutes 24seconds for $71^{\circ}C$ ambient temperature with input power of 11W

  • PDF