Evauation of Hygienic Status of High School Foodservice using ATP Bioluminescence Assay & Microorganism Test Strips (ATP Bioluminescence와 간이미생물배지를 이용한 고등학교 급식시설의 위생상태 조사연구)

  • Jang, Jae-Seon;Hwang, Seong-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.5
    • /
    • pp.918-925
    • /
    • 2015
  • An investigation was conducted to evaluate the hygienic status of 33 high school foodservice systems in Yongin city by using hygiene management guide checklist, ATP bioluminescence assay and microbe inspection petrifilm (APC, coliform group, Staphylococcus aureus) of food utensils during use. The 22 hygiene management guide checklist items about facilities, personal hygiene, food control, distribution, washing and disinfection had good grade but there were some inadequate behaviors on observation. The inspection results showed their sanitary condition met the level B of the recommendation of Korea method, it means sanitary management system get settled but more practical CCP system was needed. ATP bioluminescence assay was conducted on surface of food facilities, ATP ranged 425~2,552 RLU on gloves, 541~70,251 RLU on apron, 1,596~88,490 RLU on working desk, 1,177~263,813 RLU on sterilizer grip, 715~32,814 RLU on sterilizer shelf, 114~619,725 RLU on refrigerator grip, 677~319,007 RLU on refrigerator shelf, 71~196,725 RLU on freezer grip, 1,535~233,375 RLU on freezer shelf. APC ranged $66.7{\pm}29.0CFU$ on freezer grip, $102.1{\pm}35.9CFU$ on refrigerator grip, $45.4{\pm}28.2CFU$ on heating cabinet grip, $58.8{\pm}40.4CFU$ on sterilizer grip, the number of coliform group ranged $5.6{\pm}4.9CFU$ on freezer grip, $9.1{\pm}8.7CFU$ on refrigerator grip, $1.2{\pm}1.1CFU$ on heating cabinet grip, $4.5{\pm}4.4CFU$ on sterilizer grip. S. aureus ranged $8.0{\pm}5.6CFU$ on freezer grip, $12.2{\pm}9.6CFU$ on refrigerator grip, $2.1{\pm}1.6CFU$ on heating cabinet grip, $11.6{\pm}6.4CFU$ on sterilizer grip.

The Development of Cleaning and Monitoring System for Pipeline Type UV Sterilizer (관로형 UV 소독기를 위한 세척 및 모니터링 시스템 개발)

  • Park, Byeung-Jun;Ryu, Ji-Hyoung;Park, Jae-Byung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6434-6440
    • /
    • 2013
  • In this paper, an integrated control system is proposed for automatic control and remote monitoring of pipeline type UV sterilizer. The proposed system can control the cleaning wiper in the sterilizer with various cleaning motions, and periodically check the contamination level of the UV lamps with the UV power sensors. Therefore, sterilizer repair and maintenance can be more effectively done. In addition, the control system based on the open-source processor can communicate with external smart devices via Bluetooth, and thus wirelessly exchange control commands and sensor data. Furthermore, the system is able to flexibly cope with changes of cleaning motions and sensors since its firmware can be wirelessly upgraded by using the smart device. Consequently, the proposed system is suitable to construct a smart sewage treatment system in small towns.

The Power Conversion System of a Sterilizer Processing for the Long Term Storage of Flours (밀가루 장기보관을 위한 살균처리 전력변환시스템)

  • 강욱중;정상화;고강훈;서기영;이현우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.27-34
    • /
    • 2001
  • There are several electricity applied sterilizers such as using high frequency, ozone, high voltage, and so on. Those sterilizers feature "because of no chemical process and no secondly environmental pollution". At the power conversion part, ZVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the propose device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduce. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with high voltage and field to and more economical and effective way, and to suggest mere improved sterilizer.

  • PDF

The improvement of sterilization effective using resonance inverter Power conversion device (공진용 인버터 전력 변환 장치를 이용한 플라즈마 살균효과 개선)

  • Kim, J.Y.;Kim, Y.M.;Kwon, S.K.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.266-269
    • /
    • 2003
  • A sterilizer equipment by using electrical energy has merits that no process of chemical and no second environmental pollution. Also, the power conversion circuit for sterilizer equipment has merits that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with plasma sterilization device, to find more economical and effective way, and to suggest more improved sterilizer.

  • PDF

A Study on the Water Sterilizer using the Microwave (마이크로파를 이용한 물 살균장치에 관한 연구)

  • 이창호;이화용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.113-117
    • /
    • 2004
  • In this paper, we present a new microwave applicator to sterilize a liquid material by using the electromagnetic energy. Also, we conducted an experiment on streamlet water with our proposed sterilizer and investigated the chosen samples according to the inspection agency The result exhibited that the total number of colitis germ and general bacillus in sterilized water has been decreased rapidly as the operating time to illuminate the microwave power risen from 10 to 60 seconds.

A Study on the Degree of Contamination of Air and Materials in a Hospital (병원내 공기오염과 물품의 항균에 대한 상태조사)

  • 차옥주
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 1982
  • The incidence of hospital infection has been seriously increased in the general hospital in recent years. This study was performed on hospital air and materials in a General Hospital in Seoul from June to December in 1980. The results were as follows: 1. Air sampling was done in multiple strategic areas by exposing standard petridishes for 5 minutes. There was a significant difference of airborne microbe between places. ($F._{99}$ = 3.2, p < 0.01). 2. The mean colony count was 8.6$\pm$6.2 colonies / plate / 5 minutes. 3. Gram stains of colony in air sampling were Gram (+) cocci 66.5%. Gram (+) rod 18.4%, Gram (-) cocci 1.3%, Gram (-) rod 8.7% Fungus 4.5%. 4. For the evaluation of sterilization of steam sterilizer and ethylene oxide gas sterilizer, biological monitoring were done by commercial spore strip. Positive culture was obtained in 2 out of 41 tests on 3 steam sterilizers, and in 3 out of 13 tests on ethylene oxide gas sterilizer. 5. Product sampling and culture were done for 2 kinds of disinfectants and 30 sets of various operation package or dressing materials. Positive culture was obtained in one disinfectants.

  • PDF

A study on the state of infection control in dental clinic (치과진료실에서의 감염관리 실태 조사)

  • Kim, Kyung-Mi;Jung, Jae-Yeon;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.3
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

Studies on the improvement of UV sterilizer for toothbrush (가정용 칫솔 UV 살균기의 성능 개선법에 관한 연구)

  • Yang, Eun-Jung;Lee, Mi-Seon;Kim, Jung-Woo
    • The Journal of Natural Sciences
    • /
    • v.11 no.1
    • /
    • pp.41-44
    • /
    • 1999
  • For the purpose of improving the UV sterilization for toothbrush, the sterilizing effects by the UV light were studied. When toothbrushes were treated with the UV light for 5, 15, 30, 60 minutes, the sufficient antibacterial effect were shown after 15 minutes with 80% of bactericidal effects. To prevent the brownish stain on the sterilizer which was caused by the long exposure of UV light, no UV treatment for two hours after 15 minutes exposure were scheduled and then 3 minutes re-exposure were performed, which showed 97% of bactericidal effect. Also, the antibacterial effects of the sterilizer showed different results depending on the position of the toothbrush, it was recommended to adjust toothbrush to be exposed by the UV light directly.

  • PDF

Efficacy and Safety Evaluation of an Air Sterilizer Equipped With an Electrolytic Salt Catalyst for the Removal of Indoor Microbial Pollutants (염촉매 전기분해 공기살균기의 효능 평가)

  • Sun Nyoung Yu;Ho-Yeon Jeon;Bu Kyung Kim;Ae-Li Kim;Kyung Il Jung;Gye Rok Jeon;Soon Cheol Ahn
    • Journal of Life Science
    • /
    • v.34 no.7
    • /
    • pp.500-508
    • /
    • 2024
  • Recently, there has been increasing interest in enhancing the indoor air quality, particularly in response to the growing utilization of public facilities. The focus of this study was on assessing the efficacy and safety of an air sterilizer equipped with electrolytic salt catalysts. To that end, we evaluated the antimicrobial activity of the vapor spraying from the air sterilizer and its cytotoxicity in condensed form on human cell lines (HaCaT, BEAS-2B, and THP-1). Against the test organisms, which comprised five bacterial strains (Staphylococcus aureus, Bacillus subtilis, Escherichia coli, Pseudomonas aeruginosa, Salmonella typhimurium) and one fungal strain (Candida albicans), the air sterilizer exhibited relatively high antimicrobial activities ranging from 10.89 to 73.98% following 1 and 3 hr of vapor spraying, which were notably time-dependent. Importantly, cytotoxicity assessments on human cells indicated no significant harmful effect even at a 1.0% concentration. Comprehensive safety evaluations included morphological observations, gene expression (Bcl-2, Bax) tests, and FACS analysis of intracellular ROS levels. Consistent with previous cytotoxicity findings, these estimates demonstrated no significant changes, highlighting the air sterilizer's safety and antimicrobial activities. In a simulated 20-hr operation within an indoor environment, the air sterilizer not only showed an 89.4% removal of total bacteria but also a 100.0% removal of Escherichia sp. and fungi. This research outlines the potential of the developed electrolytic salt catalyst air sterilizer to effectively remove indoor microbial pollutants without compromising human safety, underscoring the solution that it offers for improving indoor air quality.

Improvement of a UV/Ozone Duplex Sterilizer (UV/Ozone 복합 살균기의 살균력 개선 연구)

  • Jee, Jung-Eun;Yang, Won-Kyun;Park, Eun-Chul;Kim, Kang-Suk;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.2
    • /
    • pp.76-82
    • /
    • 2008
  • We investigated sterilization characteristics of UV lights by counting the number of bacteria units with varying sterilization time and distance from the light source. We focused on an idea that UV light of 184.9 nm could generate ozone and developed a new sterilizer. The UV-ozone duplex system sterilized bacteria faster than UV-only sterilizers. To reduce shadowing effects by target objects, we used UV transparent quartz plate as a support and put a reflecting plate. Distribution of UV irradiation intensity and ozone supply were analyzed by a 3D model and measured by a semiconductor UV sensor. But even with an Al reflector, multi-layered pens could not be treated properly from UV irradiation only. Ozone generating lamp could treat more uniformly multi-layered pens with a stirring fan by supplying ozone to shadowed surfaces.