• 제목/요약/키워드: Sterilizer

검색결과 94건 처리시간 0.029초

공기정화 살균기 개발 및 성능검증 연구 (A Study on Development and Performance Test of an Air Purify-sterilizer)

  • 정재윤;장조원
    • 한국항공운항학회지
    • /
    • 제14권3호
    • /
    • pp.51-59
    • /
    • 2006
  • The air purity-sterilizer was developed and the CFD and experimental studies were carried out in order to investigate the performance of a air purity-sterilizer. Overhaul and exchange efficiency were increased by the modularization of the air purity-sterilizer. The good performance was validated by the hot-wire measurements and flow simulations in the room. Mean velocities at the exit of the air purity-sterilizer were 0.91, 1.62, 1.99, and 6.14 m/sec according to the fan mode. And the flow visualization of pured air was shown by using CFD flow simulation in the room of 24, 50 pyeong. The results show that the air purity-sterilizer has a high performance enough to produce air purity-sterilizer on a commercial scale.

  • PDF

레토르트용 연속 살균기의 개발 (Design of Continuous Sterilizer for Retort Pouch)

  • 박철재
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.57-63
    • /
    • 2015
  • In this paper, we developed a continuous sterilizer in order to improve the productivity of the retort product. To this end, we design the sterilizer with a product inlet, outlet, and chain for continuously conveying the retort. The temperature analysis is performed to optimize the design parameters of the internal sterilizer. The experimental apparatus is developed to verify the productivity of the sterilizer based on the temperature analysis. The test is performed to optimize the evaluation parameters using Box-Behnken design method of a response surface methodology. From the test, the productivity of the continuous sterilizer is improved over 1,000 kg/h.

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.

미생물 안전을 위한 승용차 실내 UVGI 살균기 설치에 관한 시뮬레이션 연구 (A Study on simulation analysis of UVGI air sterilizer installation in a car for microbiological safety)

  • 최상곤
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.279-287
    • /
    • 2014
  • The recent rise in SARS and bird flu infections around the world has raised the interest in studying the habits of air borne pathogens such as germs and viruses. In this study, simulations were carried out to predict the performance of UVGI air sterilizer at preventing airborne infections inside a car, based on the installation position and the removing effect of the UVGI air sterilizer. Simulation results showed that the UVGI air sterilizer was most effective when located at the rear side of the front seats. It was also showed that when the out-air mode and the UVGI air sterilizer were set to the highest capacity, the microbial safety levels were maintained in a car for 21 hours.

연속 살균기의 장력 및 온도제어에 관한 연구 (A Study on Tension and Temperature Control for Continuous Sterilizer)

  • 박철재
    • 한국산업융합학회 논문집
    • /
    • 제27권4_2호
    • /
    • pp.869-876
    • /
    • 2024
  • In this paper, a tension control system is developed to control temperature deviation due to tension fluctuations in a continuous sterilizer. The fluid flow in the sterilizer is expressed by conservation equations, and the tension control system is modeled using the mass flow rate between two transfer rolls. We analyze the elastic and shear deformation of the internal chain in the sterilizer. As a result of the tension control simulation, it is seen that the tension is recovered about 0.3 sec after the tension deviation. Using a experimental test, we show that the average temperature is similar, but the temperature deviation is improved from 3.1℃ to 1.2℃.

Study on mold sterilization using High Electric field generation system

  • Kee-Yeon Joe
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.535-538
    • /
    • 2000
  • There are several electricity applied sterilizers such as sterilizer with high frequency sterilizer with ozone sterilizer with high voltage and so on Those sterilizers feature "because there is no chemical process there is no secondly environmental pollution" At the power conversion part ZVS and ZCS methods have been used that it results in reduced switching loss miniaturized size and lightened weight, Besides the current in the device is smaller than that of existing method. Thus it is expected that the cost of sterilization process when quality of the device is measured by power consumption will be reduced.e reduced.

  • PDF

살균처리 장치용 전력변환장치 (Power Converter System for Sterilization processing Device)

  • 강욱중;고강훈;서기영;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.237-240
    • /
    • 2001
  • There are several electricity applied sterilizers such as sterilizer with high frequency, sterilizer with ozone, sterilizer with high voltage, and so on. Those sterilizers feature “because there is no chemical process, there is no secondly environmental pollution” At the power conversion part, AVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced.

  • PDF

연속 살균기의 온도제어 및 최적설계에 관한 연구 (Study on Temperature Control and Optimal Design for Continuous Sterilizer)

  • 박철재
    • 대한기계학회논문집A
    • /
    • 제39권8호
    • /
    • pp.813-821
    • /
    • 2015
  • 본 논문에서는 배치식 살균기의 문제점을 분석하여 연속 살균기를 모델링하고 설계하였으며 온도편차를 제어하였다. 살균기의 노즐 직경, 홀 직경, 노즐 길이 등의 설계 파라미터를 이용하여 온도를 해석하였다. 살균기의 온도편차에 중요한 노즐 직경, 제트박스의 직경, 노즐의 홀 피치 등의 설계 파라미터를 반응표면분석법에 의하여 최적화하였다. 그리고 본 연구에서 제안한 설계 파라미터를 이용하여 살균기의 실험장치를 개발하여 온라인으로 테스트를 실시하였다. 온라인 테스트 결과 목표온도까지 상승하는데 약 7.3 min 소요되었고 온도편차는 약 $0.84^{\circ}C$로 양호하였으며 해석적으로 최적화를 실시한 결과와 동일한 최적조건을 도출하였다.

공기감염 전파방지를 위한 UVC 공기살균기 성능평가에 관한 연구 (The Study on the Performance Estimation of UVC Air Sterilizer for Preventing Transmission of Air Borne Contagion)

  • 최상곤;홍진관
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.581-586
    • /
    • 2005
  • Recently, the use of UVGI system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and indoor air sterilization effect of UV ray for preventing transimission of air borne contagion was investigated by using manufactured UVC air sterilizer. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature in irradiance performance test. An individual microbiological killing effectiveness experiment also shows that the average kill rate of two microbiological samples such as bacteria and fungus is about $92\%$ by using manufactured UVC air sterilizer. Additionally irradiance performance experimental results also show that the ballast is very important factor to keep up irradiance performance of UVC lamp.