• Title/Summary/Keyword: Sterilization methods

Search Result 224, Processing Time 0.027 seconds

A Study Assessing Support Project of Korean Medical Treatment in Infertility in Jecheon (제천시 한방 난임 치료 지원 사업에 관한 연구)

  • Nam, Eun-Young;Yoo, Su-Jeong;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.2
    • /
    • pp.120-132
    • /
    • 2015
  • Objectives : This study aims to assess whether Korean medical treatment in infertile couple is effective on clinical pregnancy. Methods : Korean medical treatment using herbal medicine, acupuncture and moxibustion was performed to thirty-one women and one man of infertility from March 2013 to April 2015. Results : After the treatment, nine patients (eight women and 1 man) of infertility became pregnant (28.13%) in thirty-two patients. In nine patients with pregnancy, five patients became spontaneous pregnant. Two patients became pregnant with in vitro fertilization (IVF), and other two patients became pregnant with intrauterine insemination (IUI). Factors influenced pregnancy assessed a shorter duration of infertility. After the treatment, survey of satisfaction in Korean medical treatment in infertility was done. Out of thirty-two patients, convenience and reliability of Korean medical treatment was reported by who had an experience of sterilization surgery. After the assessment, seven patients who had an experience of sterilization surgery and beame pregnant were having more convenience than twelve patients who were not pregnant despite sterilization surgery. Conclusions : This study suggests Korean medical treatment is useful for infertile women and men, in reverse proportion to shorter duration of infertility.

Surface Treatment of Eggshells with Low-Energy Electron Beam

  • Kataoka, Noriaki;Kawahara, Daigo;Sekiguchi, Masayuki
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Background: Salmonella enteritidis (SE) was the main cause of the pandemic of foodborne salmonellosis. The surface of eggs' shells can be contaminated with this bacterium; however, washing them with sodium hypochlorite solution not only reduces their flavor but also heavily impacts the environment. An alternative to this is surface sterilization using low-energy electron beam. It is known that irradiation with 1 kGy resulted in a significant 3.9 log reduction (reduction factor of 10,000) in detectable SE on the shell. FAO/IAEA/WHO indicates irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard. On the other hand, the Food and Drug Administration has deemed a dose of up to 3 kGy is allowable for eggs. However, the maximum dose permitted to be absorbed by an edible part (i.e., internal dose) is 0.1 Gy in Japan and 0.5 Gy in European Union. Materials and Methods: The electron beam (EB) depth dose distribution in the eggshell was calculated by the Monte Carlo method. The internal dose was also estimated by Monte Carlo simulation and experimentation. Results and Discussion: The EB depth dose distribution for the eggshells indicated that acceleration voltages between 80 and 200 kV were optimal for eggshell sterilization. It was also found that acceleration voltages between 80 and 150 kV were suitable for reducing the internal dose to ≤ 0.10 Gy. Conclusion: The optimum irradiative conditions for sterilizing only eggshells with an EB were between 80 and 150 kV.

Impact of Thermal and Nonthermal Technologies in Milk Processing (우유의 가열 및 비가열 살균 기술에 관한 연구 동향)

  • Park, Jung Geun;Lee, Yeo Jin;Yoon, Joon Yong;Om, Ae Son
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.3
    • /
    • pp.223-229
    • /
    • 2015
  • Milk is a food with high nutritional value as it contains abundant water, proteins, vitamins, lactose, fat, minerals, enzymes, etc. However, in order to make milk suitable for intake, it should be thermally treated to eliminate microbiologically hazardous factors. Heat treatment is an essential sanitation process for milk, but various precautions must be taken in order to process and preserve it. Therefore, various techniques should be developed to minimize the nutrient loss and to ensure that milk is safe for consumption, conservation, and distribution. However, the existing thermal pasteurization methods are harmful and increase the nutrient loss; moreover, no new thermal pasteurization methods are being researched that are safe for the human health and minimize the nutrient loss. Hence, this study aims to review new processes for thermal (low temperatures) and no thermal pasteurization methods that can minimize the nutrient loss during milk pasteurization.

  • PDF

Prooxidant-antioxidant balance and malondialdehyde over time in adult rats after tubal sterilization and vasectomy

  • Faramarzi, Azita;Seifi, Behjat;Sadeghipour, Hamid Reza;Shabanzadeh, Alireza;Ebrahimpoor, Mitra
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.39 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Objective: Sterilization (tubal sterilization and vasectomy) is a widely applied contraceptive method worldwide. Although most studies have described sterilization as a safe method, there are reports of tubal ligation (TL) and vasectomy complications. The aim of this study was to evaluate the effects of TL and vasectomy on the serum oxidative stress, specifically prooxidant-antioxidant balance (PAB) and malondialdehyde (MDA) levels, over time. Methods: Male and female rats were classified into vasectomy, sham-vasectomy, TL, and sham-TL groups, respectively. The PAB and MDA levels were measured on days 15 and 45 and months 3 and 6 after the intervention. For female rats, blood sampling was performed during the diestrous phase and estradiol and progesterone were also measured. Results: Serum PAB and MDA increased after TL (p<0.05). Vasectomy increased serum MDA remarkably after 45 days, 3 months, and 6 months (p<0.05). After vasectomy, serum PAB also increased although not significantly. Serum estradiol and progesterone decreased remarkably in the TL group compared to the sham group (p<0.05). Conclusion: Bilateral TL and vasectomy both increase the serum oxidative stress; however the imbalance after TL was very noticeable. As for the TL, the reduction of serum estrogen levels can be involved in this imbalance. Complications followed by TL or vasectomy could be due to increased levels of oxidants. Thus, prescribing antioxidants during and or after surgery may be a solution.

Characteristics of Bioaerosol Generation of Household Humidifiers by User Practices (가정용 가습기의 사용자 습관에 따른 실내공기 중 바이오에어로졸의 발생특성)

  • Kim, Ik-Hyeon;Kim, Ki Youn;Kim, Daekeun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.503-509
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate the generation characteristics of airborne bacteria and fungi while operating a household humidifier, in consideration of user habits. Methods: Microbial samples were collected in a closed chamber with a total volume of 2.76 $m^3$, in which a humidifier was operated according to experimental strategies. A cultivation method based on the viable counts of mesophilic heterotrophic bacteria and fungi was performed. Experimental strategies were divided into three classes: the type of water in the water reservoir (tap water, cooled boiled water); the frequency of filling the reservoir (refill every day, no refill); and the sterilization method (sterilization function mode, humidifier disinfectants). Results: Significant increases in the concentration of airborne bacteria were observed while the humidifier was in operation. The concentration had increased to 2,407 $CFU/m^3$ by 120 hours when tap water filled the reservoir without any application of sterilization, while for cooled boiled water, it was merely 393 $CFU/m^3$ at a similar time point. Usages of disinfectant in the water tank were more effective in decreasing bioaerosol generation compared to sterilization function mode operation. Generation characteristics of airborne fungi were similar to those of bacteria, but the levels were not significant in all experiments. Calculated exposure factor can be used as an indicator to compare biorisk exposure. Conclusion: This study identified the potential for bioaerosol generation in indoor environments while operating a household humidifier. User practices were critical in the generation of bioaerosol, or more specifically, airborne bacteria. Proper usage of a humidifier ensures that any biorisks resulting from generated bioaerosol can be prevented.

Methods of temperature measurement of medium in bottle during sterilization (병재배 배지살균 시 배지내부의 실시간 온도측정 방법)

  • Cheong, Jong-Chun;Jhune, Chang-Sung;Lee, Chan-Jung;Oh, Jin-A;Shin, Pyeong-Gyun
    • Journal of Mushroom
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2011
  • This study was carried out to develop a method related to measuring the temperature of sterile medium in bottle cultivation. When the medium is sterilized, the device is able to be inserted inside of the medium and the temperature can be directly measured in real time although high temperature and pressure are detected in the sterilization. This device can be able to measure the sterilization temperature in short intervals inside of autoclave and medium used in bottle cultivation. As the method were applied to the field cultivation of mushroom, we could produce mushroom in consistent manner through the optimum sterilization of the medium.

Sterilization effect of atmospheric pressure non-thermal air plasma on dental instruments

  • Sung, Su-Jin;Huh, Jung-Bo;Yun, Mi-Jung;Chang, Brian Myung W.;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.2-8
    • /
    • 2013
  • PURPOSE. Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated. MATERIALS AND METHODS. After inoculating E. coli and B. subtilis the diamond burs and polyvinyl siloxane materials were sterilized by exposing them to the plasma for different lengths of time (30, 60, 90, 120, 180 and, 240 seconds). The diamond burs and polyvinyl siloxane materials were immersed in PBS solutions, cultured on agar plates and quantified by counting the colony forming units. The data were analyzed using one-way ANOVA and significance was assessed by the LSD post hoc test (${\alpha}$=0.05). RESULTS. The device was effective in killing E. coli contained in the plasma device compared with the UV sterilizer. The atmospheric pressure non-thermal air plasma device contributed greatly to the sterilization of diamond burs and polyvinyl siloxane materials inoculated with E. coli and B. subtilis. Diamond burs and polyvinyl siloxane materials inoculated with E. coli was effective after 60 and 90 seconds. The diamond burs and polyvinyl siloxane materials inoculated with B. subtilis was effective after 120 and 180 seconds. CONCLUSION. The atmospheric pressure non-thermal air plasma device was effective in killing both E. coli and B. subtilis, and was more effective in killing E. coli than the UV sterilizer.

Infection management for emergency rescue equipment (119 구급대의 구급장비 감염 관리와 실태조사)

  • Park, So-Mi;Lee, Hyo-Ju;Choi, Jang-Hui;Kim, Jong-Ho
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.1
    • /
    • pp.87-98
    • /
    • 2017
  • Purpose: This study investigated the use of infection management and the frequency of emergency equipment sterilization by emergency rescue crews to provide basic guidelines and suggestions for infection control. Methods: A self-reported questionnaire was completed by 160 emergency medical technician rescue crews in J area from May 7 to May 22 in 2015. The questionnaire consisted of 95 items, including the general characteristics of the subjects (8 items), the use of emergency equipment (33 items), the frequency of facility sterilization (33 items), infection control (12 items), vaccination (4 items), and the use of personal protective equipment (5 items). Results: In all, 97.3% of respondents were aware of the "Guidelines of Infection management for Rescue Operators' and 90.9% received training on infection control. A total of 72.7% and 47.3% of rescue centers were equipped with disinfection facilities and laundry rooms, respectively. The average frequency of sterilization was $3.17{\pm}0.75$, which significantly differed for teams with more clinical experience (p=.050) and teams with three members (p=.030). The average score for individual protective equipment supplies was $1.95{\pm}0.66$. Conclusion: For proper infection management of emergency equipment, our results suggest that the number of crew members should be increased for each ambulance, protective equipment and rescue products should be supplied, and the number of facilities for sterilization and laundry at rescue centers should be doubled.

Evaluation of Nonthermal Plasma Treatment by Measurement of Stored Citrus Properties

  • Seo, Youngwook;Park, Jong-Ryul;Park, Hoe Man
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.401-409
    • /
    • 2018
  • Decay of fruit is one of the greatest issues in fruit storage. Purpose: In this study, citrus sterilization was performed to evaluate a dry sterilization method using an atmospheric-pressure nonthermal plasma treatment based on a dielectric-barrier discharge technique. Methods: Citrus samples were stored under four different environmental conditions as follows: group A had cold storage with plasma treatment with a temperature of $6.2{\pm}1.0^{\circ}C$ and relative humidity (RH) of $93.4{\pm}8.2%$, group B had ambient-temperature storage with $22.9{\pm}2.3^{\circ}C$ and $82.1{\pm}4.5%$ RH, group C ambient-temperature storage with plasma treatment with $25.3{\pm}2.2^{\circ}C$ and $90.0{\pm}2.8%$ RH, and group D had cold storage with $5.7{\pm}1.0^{\circ}C$ and $93.4{\pm}6.5%$ RH. Results: As a result of citrus surface sterilization by plasma treatment, treatment groups A and C together showed an average of 16.1 CFU/mL of mold colonies, while control groups B and D showed an average of $2.2{\times}10^2CFU/mL$ or approximately 13 times greater than the treatment groups. Regarding the mean concentration of aerobic bacteria colonies, the treatment groups (A and C) and control groups (B and D) showed an average of 7.1 CFU/mL and $1.9{\times}10^3CFU/mL$, respectively. This is approximately a 270-fold difference in the concentration of pathogen colonies between treatment and control groups. Conclusions: The results showed the potential of nonthermal plasma treatment for citrus storage in enhancing storage duration and quality preservation.

Colonization of Pathogens in Earphones and Observation of Effective Sterilization Methods and Cycles

  • Kwon, Hyeokjin;Jeong, Myeongguk;Go, Shinjee;Kim, Yeojin;Kim, Yein;Kim, Yeeun;Roh, Seungjun;Lee, Seonggwang;Choi, Go-Eun
    • Biomedical Science Letters
    • /
    • v.28 no.3
    • /
    • pp.186-191
    • /
    • 2022
  • The use of earphones has recently been widely used around the world. In currently, students wear earphones a lot in a daily life. The types of earphones are open-earphones, Canalphones, and headphones. Many students don't periodically to sterilization their earphones. Therefore, it can be an incubator that can induced ear infections. The objective of this study was to detect the pathogenic bacteria from the earphones used by the students. A total of 3 type earphones swabs were collected by sterile cotton swabs. The swabs were inoculated onto BHI agar and incubated aerobically 48 hour at 37℃. 16s rRNA PCR, electrophoresis and sequencing were performed to confirm the identification of all the bacterial isolates. As a result, 24 pathogens were identified in sequencing. Three types of earphones were sterilized in three ways: ultraviolet (UV), 70% ethyl alcohol, and antibacterial wet tissue. If you use earphones for a long time without disinfecting them for a long time, it causes various diseases such as external ear infections. The findings of this study the users periodically to sterilization their respective earphones.