• Title/Summary/Keyword: Stereotactic radiation therapy

Search Result 142, Processing Time 0.025 seconds

The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients (RPM SystemTM을 이용한 호흡 관찰의 유용성 평가)

  • Park, hyun jun;Bae, sun myeong;Baek, Geum Mun;Kang, tae young;Seo, Dong Rin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.17-25
    • /
    • 2016
  • Purpose : The purpose of this study is to evaluate the variability of tumor motion and respiration pattern in lung cancer patients undergoing Stereotactic Body RadioTherapy(SBRT) by using On-Board imager (OBI) system and Real-time Position Management (RPM) System. Materials and Methods : This study population consisted of 60 lung cancer patient treated with stereotactic body radiotherapy (48 Gy / 4 fractions). Of these, 30 were treated with gating (group 1) and 30 without gating(group2): typically the patients whose tumors showed three-dimensional respiratory motion > 10 mm were selected for gating. 4-dimensional Computed Tomography (4DCT). Cone Beam CT (CBCT) and Fluoroscopy images were used to measure the tumor motion. RPM system was used to evaluate the variability of respiration pattern on SBRT for group1. Results : The mean difference of tumor motion among 4DCT, CBCT and Fluoroscopy images in the cranio-caudal direction was 2.3 mm in group 1, 2. The maximum difference was 12.5 mm in the group 1 and 8.5 mm in group 2. The number of treatment fractions that patient's respiration pattern was within Upper-Lower threshold on SBRT in group 2 was 31 fractions. A patient who exhibited the most unstable pattern exceeded 108 times in a fraction Conclusion : Although many patients in group 1 and 2 kept the reproducibility of tumor motion within 5 mm during their treatment, some patients exhibited variability of tumor motion in the CBCT and Fluoroscopy images. It was possible to improve the accuracy of dose delivery in SBRT without gating for lung cancer patient by using RPM system.

  • PDF

Frameless Fractionated Stereotactic Radiaton Therapy in Recurrent Head & Neck Cancers (국소재발된 두경부종양의 무고정틀 정위적 분할방사선치료)

  • Kim In-Ah;Choi Ihl-Bhong;Jang Ji-Young;Kang Ki-Mun;Jho Seung-Ho;Kim Hyung-Tae;Lee Kyung-Jin;Choi Chang-Rak
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.156-163
    • /
    • 1998
  • Background & Objectives: Frameless fractionated stereotactic radiotherapy(FFSRT) is a modification of stereotactic radiosurgery(SRS) with radiobiologic advantage of fractionation without losing mechanical accuracy of SRS. Local recurrence of head and neck cancer at or near skull base benefit from reirradiation. Main barrier to successful palliation is dose limitation secondary to normal tissue tolerance. We try to evaluate the efficacy and safety of FFSRT as a new modality of reirradaton in these challenging patients. Materials & Methods: Seven patients with recurrent head & neck cancer involving at or near skull base received FFSRT from September 1995 to November 1997. Six patients with nasopharyngeal cancer had received induction chemotherapy and curative radiation therapy. One patient with maxillary sinus cancer had received total maxillectomy and postoperative radiation therapy as a initial treatment. Follow-up ranged from 11 to 32 months with median of 24 months. Three of 7 patients received hyperfractionated radiation therapy(1.1-1.2Gy/fraction, bid, total 19.8-24Gy) just before FFSRT. All patients received FFSRT(3-5Gy/fraction, total 15-30Gy/5-10fractions). Chemotherapy(cis-platin $100mg/m^2$) were given concurrently with FFSRT in four patients. Second course of FFSRT were given in 4 patients with progression or recurrence after initial FFSRT. Because IF(irregularity factor; ratio of surface area of target to the surface area of sphere with same volume as a target) is too big to use conventional stereotactic RT using multiple arc method for protection of radiation damage to critical normal tissue, all patients received FFSRT with conformal method using irregular static ports. Results: Five of 7 patients showed complete remission in follow-up CT &/or MRI. Three of these five patients who developed marginal, in-field, and out-field recurrences, respectively. Another one of complete responders has been dead of G-I bleeding without evidence of local recurrence. One partial responder who showed progressive disease 15 months after initial FFSRT has received additional FFSRT, and then he is well-being with symptomatic improvement. One minmal responder who showed progression of locoregional disease 9 months after $1^{st}$ FFSRT has received 2nd FFSRT, and then he is alive with stable disease. Five of 7 case had showed direct invasion to skull base and had complaint headache and various symptoms of cranial nerve involvement. Four of these five case showed improvement of neurologic symptoms after FFSRT. No significant neurologic complicaltion related to FFSRT was observed during follow-up periods. Tumor volumes were ranged from 3.9 to 50.7 cc and surface area ranged from 16.1 to $114.9cm^2$. IF ranged from 1.21 to 1.74. The average ratio of volume of prescription isodose shell to target volume was 1.02 that indicated the improvement of target coverage and dose distribution with FFSRT with conformal method compared to target coverage with FFSRT with multiple arc method. Conclusion: Our initial experience suggests that FFSRT with conformal method was relatively effective and safe modality in the treatment of recurrent head and neck cancer involving at or near skull base. Treatment benefit included good palliation of symptoms and reasonable radiographic response. However, more experience and additional follow-up are needed to better assess its ultimate role in treating these challenging patients.

  • PDF

Local ablative radiotherapy for oligometastatic non-small cell lung cancer

  • Suh, Yang-Gun;Cho, Jaeho
    • Radiation Oncology Journal
    • /
    • v.37 no.3
    • /
    • pp.149-155
    • /
    • 2019
  • In metastatic non-small cell lung cancer (NSCLC), the role of radiotherapy (RT) has been limited to palliation to alleviate the symptoms. However, with the development of advanced RT techniques, recent advances in immuno-oncology therapy targeting programmed death 1 (PD-1) and programmed death ligand 1 (PD-L1) and targeted agents for epidermal growth factor receptor (EGFR) mutation or anaplastic lymphoma kinase (ALK) translocation allowed new roles of RT in these patients. Within this metastatic population, there is a subset of patients with a limited number of sites of metastatic disease, termed as oligometastasis that can achieve long-term survival from aggressive local management. There is no consensus on the definition of oligometastasis; however, most clinical trials define oligometastasis as having 3 to 5 metastatic lesions. Recent phase II randomized clinical trials have shown that ablative RT, including stereotactic ablative body radiotherapy (SABR) and hypofractionated RT, to primary and metastatic sites improved progression-free survival (PFS) and overall survival (OS) in patients with oligometastatic NSCLC. The PEMBRO-RT study, a randomized phase II study comparing SABR prior to pembrolizumab therapy and pembrolizumab therapy alone, revealed that the addition of SABR improved the overall response, PFS, and OS in patients with advanced NSCLC. The efficacy of RT in oligometastatic lung cancer has only been studied in phase II studies; therefore, large-scale phase III studies are needed to confirm the benefit of local ablative RT in patients with oligometastatic NSCLC. Local intensified RT to primary and metastatic lesions is expected to become an important treatment paradigm in the near future in patients with metastatic lung cancer.

Stereotactic Radiosurgery

  • Chung, Hyun-Tai;Lee, Dong-Joon
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.63-70
    • /
    • 2020
  • Stereotactic radiosurgery is one of the most sophisticated forms of modern advanced radiation therapy. Unlike conventional fractionated radiotherapy, stereotactic radiosurgery uses a high dose of radiation with steep gradient precisely delivered to target lesions. Lars Leksell presented the principle of radiosurgery in 1951. Gamma Knife® (GK) is the first radiosurgery device used in clinics, and the first patient was treated in the winter of 1967. The first GK unit had 179 cobalt 60 sources distributed on a hemispherical surface. A patient could move only in a single direction. Treatment planning was performed manually and took more than a day. The latest model, Gamma Knife® IconTM, shares the same principle but has many new dazzling characteristics. In this article, first, a brief history of radiosurgery was described. Then, the physical properties of modern radiosurgery machines and physicists' endeavors to assure the quality of radiosurgery were described. Intrinsic characteristics of modern radiosurgery devices such as small fields, steep dose distribution producing sharp penumbra, and multi-directionality of the beam were reviewed together with the techniques to assess the accuracy of these devices. The reference conditions and principles of GK dosimetry given in the most recent international standard protocol, International Atomic Energy Agency TRS 483, were shortly reviewed, and several points needing careful revisions were highlighted. Understanding the principles and physics of radiosurgery will be helpful for modern medical physicists.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.

Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery (정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구)

  • Kim Sang Hwan;Ryu Ji Ok;Kim Baek Kyu;Kim Yong ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.43-48
    • /
    • 1999
  • Purpose : For practical application of the MR image for stereotactic radiosurgery, the target point achieved by acquisition of MR image in a relatively homogeneous phantom has to agree with the actual isocenter of irradiation in real radiosurgery and the amount of distortion of the MR image should be known. Materials and Methods : A dosimetric film with a random target point was inserted into a radish vertically and horizontally on axis Z and they were fixed with a headring. After image acquisition by stereotactic radiosurgery planning system, we achieved stereotactic coordinate of the target point and examined irradiation using the coordinate acquired as isocenter. After the irradiation, the film in the radish was developed and processed and the degree of coincidence between the target point marked on the film and the center of the radiation distribution. In order to measure the degree of distortion of the MR image in a different way, an acryl phantom was made and punctures were made at intervals of 1 cm and a drop of oil was dropped into it. Then, it was inserted into the radish vertically and horizontally on axis Z to acquire the MR image. Each coordinate was achieved and the estimation of distortion of MR image was made both in vertical and horizontal directions Results : The film from the radio was developed and for the one inserted vertically on axis Z, there was a good coincidence in the discrepancy between the target point marked on the film and the center of the radiation distribution. For the one inserted horizontally, the discrepancy between them was under 0.5 mm. As a result of estimating distortion of MR image using acryl, the discrepancy was under 0.45 mm in the case of the phantom inserted vertically on axis Z, and that of the one inserted horizontally was 1.4 mm. Conclusion : We were able to confirm good coincidence in homogeneous phantom in actual treatment position of radiosurgery using the MR image and the discrepancy measured in the analysis of distortion of the MR image did not exceed the permissible level. Therefore, it was evident the system of the hospital is suitable for radiosurgery using MR image.

  • PDF

Clinical significance of radiation-induced liver disease after stereotactic body radiation therapy for hepatocellular carcinoma

  • Jun, Baek Gyu;Kim, Young Don;Cheon, Gab Jin;Kim, Eun Seog;Jwa, Eunjin;Kim, Sang Gyune;Kim, Young Seok;Kim, Boo Sung;Jeong, Soung Won;Jang, Jae Young;Lee, Sae Hwan;Kim, Hong Soo
    • The Korean journal of internal medicine
    • /
    • v.33 no.6
    • /
    • pp.1093-1102
    • /
    • 2018
  • Background/Aims: The aim of this study was to investigate parameters that predict radiation-induced liver disease (RILD) following stereotactic body radiotherapy (SBRT) in patients with hepatocellular carcinoma (HCC) and to identify the clinical significance of RILD. Methods: We retrospectively reviewed the medical records of 117 HCC patients who were treated by SBRT from March 2011 to February 2015. RILD was defined as elevated liver transaminases more than five times the upper normal limit or a worsening of Child-Pugh (CP) score by 2 within 3 months after SBRT. All patients were assessed at 1 month and every 3 months after SBRT. Results: Median follow-up was 22.5 months (range, 3 to 56) after SBRT. RILD was developed in 29 of the 117 patients (24.7%). On univariate analysis, significant predictive factors of RILD were pretreatment CP score (p < 0.001) and normal liver volume (p = 0.002). Multivariate analysis showed that CP score was a significant predictor of RILD (p < 0.001). The incidence of RILD increased above a CP score of 6 remarkably. The rate of recovery from RILD decreased significantly above a CP score of 8. Survival analysis showed that CP score was an independent prognostic factor of overall survival (p = 0.001). Conclusions: CP score is a significant factor to predict RILD in patients with chronic liver disease. RILD can be tolerated by patients with a CP score ${\leq}7$. However, careful monitoring of liver function is needed for patients with a CP score 7 after SBRT.

Comparison of the Dose Distributions with Beam Arrangements in the Stereotactic Body Radiotherapy (SBRT) for Primary Lung Cancer (원발성 폐암에서 정위적 체부 방사선치료의 빔 배열에 따른 선량분포의 비교)

  • Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.110-115
    • /
    • 2014
  • To compare 2 beam arrangements, circumferential equally angles (EA) beams or partially angles (PA) beams for stereotactic body radiation therapy (SBRT) of primary lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target, ipsilateral lung, contralateral lung, and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 12 patients, four treatment plans were generated per data sets ($IMRT_{EA}$, $IMRT_{PA}$, $VMAT_{EA}$, $VMAT_{PA}$). The prescribed dose (PD) was 60 Gy in 4 fractions to 95% of the planning target volume (PTV) for a 6-MV photon beam. When compared with the IMRT and VMAT treatment plan for 2 beams, conformity index, homogeneity index, high dose spillage, D2 cm (Dmax at a distance ${\geq}2cm$ beyond the PTV), R50 (ratio of volume circumscribed by the 50% isodose line and the PTV), resulted in similar. But Dmax of the Organ at risk (OAR), spinal cord, trachea, resulted in differ between four treatment plans. Especially $HDS_{location}$ showed big difference in 21.63% vs. 26.46%.