• 제목/요약/키워드: Stereotactic Image Guidance

검색결과 7건 처리시간 0.022초

의료품질의 향상을 위한 두피절개 및 드레싱 방법의 개선 효과 분석 : CT영상안내에 의한 직선형 또는 S자형 두피절개와 액상 드레싱효과 (Effectiveness of incisions, and Dressing to increase Medical Quality : In Linear or Sigmoid Incisions, and Liquid Wound Dressing for Computer Image Guided Craniotomy)

  • 조준;엄기수;이동규;박근상;김미영
    • 품질경영학회지
    • /
    • 제34권4호
    • /
    • pp.40-50
    • /
    • 2006
  • The authors aimed to analyze the quality improvement efficiency of wound dressing with 2-octyl cyanoacrylate(2-OCA) in stereotactic image guided linear or sigmoid incisions in a cohort of consecutive craniotomy patients, and to compare clinical results with those of iodine-dressing and silk sutured patients underwent conventional craniotomy surgery with large pedicle flap incisions without stereotactic guidance. In methods, 26 patients were involved as the study group at one hospital. We retrospectively compared their results with those of 38 consecutive control patients at the same unit. The suggested new medical material, 2-octyl cyanoacrylate(2-OCA), resultantly decreased or prevented the contaminated fluid influx from scalp outside. The mean infection rate for the control group (7.89%) was relatively higher than that of the study group (3.85%). In addition, the use of stereotactic image guided craniotomy was significant to reduce operation time, to simplify operative procedures and to decrease potential risk factors.

사이버나이프를 이용한 수술 불가능한 재발성 구강암의 치험례 (CYBERKNIFE RADIOSURGERY FOR INOPERABLE RECURRED ORAL CANCER)

  • 김용각;이태희;김철;김성진;김혁
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권1호
    • /
    • pp.65-68
    • /
    • 2004
  • CyberKnife is a stereotactic radiosurgery system which could be used to treat many tumors and lesions. It provides the surgeon unparalleled flexibility in targeting using a compact light linear accelerator mounted on a robotic arm. Advanced image guidance technology tracks patient and target position during treatment, ensuring accuracy without the use of an invasive head frame. CyberKnife with Dynamic Tracking Software is cleared to provide radiosurgery for lesions anywhere in the body when radiation treatment is indicated. It has often been used to radiosurgically treat otherwise untreatable tumors and malformations. Moreover, this instrument treats tumors at body sites, most of which are unreachable by other stereotactic systems. Compared with conventional radiotherapy, it is fundamentally different that using non-invasive, frameless, no excessive radiation exposure to normal tissue. In oral malignant neoplasm, surgical excision and radiation therapy should be tried first, additionally chemotherapy could be considered. However, after failure of conventional therapies, patients had poor systemic condition and surgical limitation. So, CyberKnife could be a suitable therapy. A 49 years man was referred in recurred mandibular cancer treated by radiotherapy. The tumor was considered inoperable, because of extensive invasion and was not expected to good response to conventional therapies. We experienced a case of CyberKnife after 4 cycle chemotherapies, so we report it with review of literature.

척추 전이암 환자의 정위적방사선치료 시 시간 경과에 따른 불확실성에 관한 연구 (A study on uncertainty by passage of time of stereotactic body radiation therapy for spine metastasis cancer)

  • 조용완;김주호;안승권;이상규;조정희
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.79-86
    • /
    • 2015
  • 목 적 : 치료 중에도 지속적으로 X-ray 영상을 획득하여 환자의 움직임을 보정하는 CyberKnife(Accuray Incorporated, USA) 치료 방식의 특성을 이용하여, 치료 중 환자의 움직임을 보정할 수 없는 경우 척추 전이암 정위적방사선치료의 적절한 치료 시간에 대해 고찰하고자 하였다. 대상 및 방법 : CyberKnife를 이용하여 정위적방사선치료를 받은 척추 전이암 환자 57명을 대상으로 하였다. 그 중 경추 환자는 8명, 흉추는 26명, 그리고 요추는 23 명이었다. 치료 중 획득한 X-ray 영상을 종합하여 치료 부위 별로 분류한 후, 치료 시작 시간을 기준으로 5 분마다 구간을 나누어 시간에 따른 환자의 움직임이 어떤 양상을 보이는지 분석하였다. 결 과 : 경추의 경우, 회전 방향으로 15 분 이후부터 움직임의 증가폭이 커지기 시작하였다. 흉추에서는 특별히 움직임이 증가하는 구간은 없었으나 시간에 따라 점차적으로 증가하는 추세를 보였기 때문에 대략 40 분 이후 의미 있는 값이 나올 것이라 추정된다. 요추의 경우, 치료 시작 20 분 이후 수직 이동 방향과 회전 방향으로 움직임이 크게 상승하는 것으로 나타났다. 결 론 : 치료 중 환자의 움직임을 보정할 수 없는 치료 시스템의 경우, 치료 시간은 경추의 경우 15 분, 흉추의 경우 40 분, 요추의 경우 20 분 이내가 적절한 것으로 사료된다. 만약 치료 시간이 이보다 긴 경우, 치료 중간에 추가적인 환자 정렬을 실시하거나 추가적인 PTV margin이 필요할 것으로 사료된다.

  • PDF

Positional uncertainties of cervical and upper thoracic spine in stereotactic body radiotherapy with thermoplastic mask immobilization

  • Jeon, Seung Hyuck;Kim, Jin Ho
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.122-128
    • /
    • 2018
  • Purpose: To investigate positional uncertainty and its correlation with clinical parameters in spine stereotactic body radiotherapy (SBRT) using thermoplastic mask (TM) immobilization. Materials and Methods: A total of 21 patients who underwent spine SBRT for cervical or upper thoracic spinal lesions were retrospectively analyzed. All patients were treated with image guidance using cone beam computed tomography (CBCT) and 4 degrees-of-freedom (DoF) positional correction. Initial, pre-treatment, and post-treatment CBCTs were analyzed. Setup error (SE), pre-treatment residual error (preRE), post-treatment residual error (postRE), intrafraction motion before treatment (IM1), and intrafraction motion during treatment (IM2) were determined from 6 DoF manual rigid registration. Results: The three-dimensional (3D) magnitudes of translational uncertainties (mean ${\pm}$ 2 standard deviation) were $3.7{\pm}3.5mm$ (SE), $0.9{\pm}0.9mm$ (preRE), $1.2{\pm}1.5mm$ (postRE), $1.4{\pm}2.4mm$ (IM1), and $0.9{\pm}1.0mm$ (IM2), and average angular differences were $1.1^{\circ}{\pm}1.2^{\circ}$ (SE), $0.9^{\circ}{\pm}1.1^{\circ}$ (preRE), $0.9^{\circ}{\pm}1.1^{\circ}$ (postRE), $0.6^{\circ}{\pm}0.9^{\circ}$ (IM1), and $0.5^{\circ}{\pm}0.5^{\circ}$ (IM2). The 3D magnitude of SE, preRE, postRE, IM1, and IM2 exceeded 2 mm in 18, 0, 3, 3, and 1 patients, respectively. No association were found between all positional uncertainties and body mass index, pain score, and treatment location (p > 0.05, Mann-Whitney test). There was a tendency of intrafraction motion to increase with overall treatment time; however, the correlation was not statistically significant (p > 0.05, Spearman rank correlation test). Conclusion: In spine SBRT using TM immobilization, CBCT and 4 DoF alignment correction, a minimum residual translational uncertainty was 2 mm. Shortening overall treatment time and 6 DoF positional correction may further reduce positional uncertainties.

폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가 (Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy)

  • 지윤서;장경환;조병철;곽정원;송시열;최은경;이상욱
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.286-293
    • /
    • 2015
  • 본 연구의 목적은 폐암의 정위체부방사선 치료 환자에 대하여 정위체부고정기구 사용 유무에 따른 셋업 정확성을 비교 평가하고자 한다. 본원에서 정위체부방사선치료를 받은 총 40명의 환자를 대상으로, 정위체부고정기구를 기반으로 한셋업 방식의 환자군 20명과 고정기구 없이 Wing board를 사용한 환자군 20명으로 구분하여 각 셋업오차를 비교, 분석 하였다. 폐암의 정위체부방사선치료는 총 4~5회에 걸쳐 48~60 Gy 조사되었다. 매 치료 전, 먼저 레이저를 이용하여 환자를 치료중심점에 위치시킨 후 On-board kV 영상장치를 이용하여 2차원 직각영상을 얻어 척추를 기준으로 환자의 위치를 조정한 다음, 3차원 체적 영상을 획득 하여 종양의 위치를 치료중심점에 일치시키고, 마지막으로 호흡에 의한 종양의 위치 확인 및 조정을 위해 2차원 직각 투시영상을 이용하였다. 각 과정에서 얻은 테이블 이동 및 회전 값을 조사하여, 셋업 군별로 계통오차 및 랜덤오차를 구하였다. 고정기구 사용유무에 따른 통계적 유의성을 검증하기 위하여 계통오차에 대한 t-test 시행을 하였고, 셋업의 재현성의 차이를 보기위해 랜덤오차에 대한 F-test를 시행하였다. 나아가 이러한 셋업 방식의 차이가 셋업 여유분의 크기 결정에 영향이 있는지 여부를 평가하기위해 치료계획체적의 여유분을 계산하여 두 방식의 차이를 비교하였다. 정위체부 고정기구를 사용했을 때의 셋업 오차는 수직방향, 길이방향, 수평방향으로 각각 $0.05{\pm}0.25cm$, $0.20{\pm}0.38cm$, $0.02{\pm}0.30cm$이었다. 반면에, Frameless immobilizer을 사용한 단순 고정방법을 사용했을 때의 셋업 오차는 수직방향에서만 통계적으로 유의하게 $-0.24{\pm}0.25cm$으로 증가함을 보였으나, 길이방향, 수평방향에 대해서는 각각 $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$의 작거나 비슷한 결과값을 보였다. 정위체부 고정기구를 사용했을 경우, 수직방향, 수직방향 및 길이방향으로의 여유분은 각각, 0.67 cm, 0.99 cm, 0.83 cm였고, Frameless immobilizer시 수직방향으로 0.75 cm, 길이방향으로 0.96 cm, 수평방향으로 0.72 cm로써 수평방향에서 최대 0.11 cm 차이가 남을 알 수 있었다. 결론적으로 정위체부고정기구를 사용하는 것이 환자 자세 재현성을 향상시켜 셋업 오차를 환자의 전후, 위아래 방향으로의 약 0.1~0.2 cm씩 줄일 수 있을 것으로 평가하였다. 다만 정위체부 고정기구 사용에 따른 시간 소요 및 치료절차의 복잡성에 비해 그 효과는 그리 크지 않았다.

사이버나이프에서 Xsight spine tracking system을 이용한 3D 표적위치보정의 유용성 평가 (Useful evaluation of 3D target location correction by using Xsight spine tracking system in CyberKnife)

  • 정영준;김상현
    • 디지털융복합연구
    • /
    • 제13권1호
    • /
    • pp.331-339
    • /
    • 2015
  • 사이버나이프치료에서 삽입된 금표지자의 삽입 개수 및 인식의 제한으로 인하여 3D DOF로 치료하는 경우 척추구조물 정렬을 가능하게 하는 Xsight spine tracking system으로 회전방향의 위치오차를 보정함으로서 표적위치오차를 개선하고, 치료방법의 대안을 제시하고자 한다. 실험결과 6D DOF에서 표적위치오차는 $0.214{\pm}0.058mm$, 종양내부에 삽입된 2개 금표지자를 이용한 3D DOF에서 $0.673{\pm}0.142mm$, 종양외부에 삽입된 2개 금표지자를 이용한 3D DOF에서 $1.126{\pm}0.253mm$, Xsight spine tracking system의 적용 한 3D DOF에서 $0.542{\pm}0.103mm$로 나타났다. 실험결과 척추 구조물로 회전방향에 대한 보정을 시행하였을 때 표적위치에 대한 정확성이 약 48% 향상되었다. 또한, 선량분포의 일치성도 약 3%가 향상되어 일치하는 것을 확인할 수 있었다. 따라서 척추구조물 정렬을 병용한 Xsight spine tracking system의 회전방향에 대한 보정은 유용한 것으로 평가 되었다.

폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구 (Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy)

  • 박재원;강민규;예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.79-86
    • /
    • 2015
  • 이 연구는 조기 폐암의 정위방사선치료에서 육안적종양체적(Gross tumor volume, GTV) 변화에 따른 적응방사선치료(ART)의 효과 및 가능성을 보기 위해 시행되었다. 영남대학교 의료원에서 정위방사선치료를 시행한 22개의 종양을 대상으로 연구를 진행하였다. 정위방사선치료는 2주에 걸쳐 48 혹은 60 Gy를 4회에 나누어 조사하는 방법으로 시행되었다. 종양체적 변화를 측정하기 위해 매 콘빔시티마다 육안적종양체적에 대한 윤곽선 그리기를 시행하였다. 그 다음 첫 번째 콘빔시티에 기준 치료계획으로 사용할 세기조절방사선치료 계획을 시행하였다. 적응방사선치료 계획을 하기 위해, 2, 3, 4번째 콘빔시티에 기준 치료계획과 동일한 빔 각도와 제약을 적용하여 각각 재 최적화 과정을 진행하였다. 이후 적응방사선치료 계획은 기준치료계획을 각각의 콘빔시티에 복사하여 생성한 비적응방사선치료 계획과 비교되었다. 평균 육안적종양체적은 10.7 cc였다. 평균 종양체적 변화는 두 번째, 세 번째, 네 번째 콘빔시티에서 각각 -1.5%, 7.3%, 25.1%였으며 세 번째 이후 변화는 통계적으로 유의하였다(p<0.05). 하지만 두 번째 콘빔시티에서는 9개의 종양 체적이 증가하였다. 적응방사선치료 계획을 시행하였을 때, 폐에서 $V_{20\;Gy}$, $D_{1500\;cc}$, $D_{1000\;cc}$가 유의하게 감소하였으며, 흉벽에 대한 $V_{30\;Gy}$$V_{32\;Gy}$ 역시 유의하게 감소하였다(p<0.05). 두 번째 콘빔시티의 종양체적이 증가한 환자들에서, 기준치료 계획에 비해 적응치료방사선치료 계획을 시행하지 않았을 때, 계획용 표적체적에 대한 선량 범위 변수 중 $D_{min}$은 8.3% 감소한 반면 (p=0.021), 적응방사선치료계획을 시행한 경우에는 차이가 없었다. 이러한 결과를 보았을 때, 적응방사선치료 계획을 함으로서 표적 선량 커버는 개선시키면서 손상위험장기에 대한 선량을 감소시킬 수 있을 것이다. 그러므로, 콘빔시티를 이용한 적응방사선치료 방법은 조기 폐암의 정위방사선치료에서 고려되어야 하겠다.