• Title/Summary/Keyword: Stereotactic

Search Result 400, Processing Time 0.035 seconds

Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom (다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인)

  • Yoo Hyung Jun;Kim Il Han;Ha Sung Whan;Park Charn Il;Hur Sun Nyung;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.179-185
    • /
    • 2002
  • Purpose : For the purpose of quality assurance of self-developed stereotactic radiosurgery system, a multi-purpose phantom was fabricated, and accuracy of radiation dose distribution during radiosurgery was measured using this phantom. Materials and Methods : A farmer chamber, a 0.125 cc ion chamber and a diode detector were used for the dosimetry. Six MV x-ray from a linear accelerator (CL2100C, Varian) with stereotactic radiosurgery technique (Green Knife) was used, and multi-purpose phantom was attached to a stereotactic frame (Fisher type). Dosimetry was done by combinations of locations of the detectors in the phantom, fixed or arc beams, gantry angles $(20^{\circ}\~100^{\circ})$, and size of the circular tertiary collimators (inner diameters of $10\~40\;mm$). Results : The measurement error was less than $0.5\%$ by Farmer chamber, $0.5\%$ for 0.125 cc ion chamber, and less than $2\%$ for diode detector for the fixed beam, single arc beam, and 5-arc beam setup. Conclusion : We confirmed the accuracy of dose distribution with the radiosurgery system developed in our institute and the data from this study would be able to be effectively used for the improvement of quality assurance of stereotactic radiosurgery or fractionated stereotactic radiotherapy system.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

Study on The Development of A New Whole Body Fame

  • Chung, Jin-Bum;Suh, Tae-Suk;Chung, Won-Kyun;Choe, Bo-Young;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.136-137
    • /
    • 2002
  • We have been researching upgrade version of a stereotactic whole body frame, used for evaluating daily setup accuracy of the patient positioning during fractionated extra-cranial stereotactic radiotherapy. Currently, we are focusing on the development of a new stereotactic whole body frame, and then will handle organ movement produced by breathing at the next stage. MeV-Green is chosen for the best immobilizer possible and the epoxy board is for the frame with the dimension of 110 em in length, 50 cm in width in order to maximize transmission rate of the beam from lateral or posterior direction and to fit CT and PET scanners with an aperture of 55 cm at least. The key point of an upgraded stereotactic whole body frame will be set on the collision-free rotation of the gantry with the frame, and the development of the checking structure for the daily patient repositioning regarding internal target.

  • PDF

Stereotactic Mesencephalotomy for Cancer - Related Facial Pain

  • Kim, Deok-Ryeong;Lee, Sang-Won;Son, Byung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.1
    • /
    • pp.71-74
    • /
    • 2014
  • Cancer-related facial pain refractory to pharmacologic management or nondestructive means is a major indication for destructive pain surgery. Stereotactic mesencephalotomy can be a valuable procedure in the management of cancer pain involving the upper extremities or the face, with the assistance of magnetic resonance imaging (MRI) and electrophysiologic mapping. A 72-year-old man presented with a 3-year history of intractable left-sided facial pain. When pharmacologic and nondestructive measures failed to provide pain alleviation, he was reexamined and diagnosed with inoperable hard palate cancer with intracranial extension. During the concurrent chemoradiation treatment, his cancer-related facial pain was aggravated and became medically intractable. After careful consideration, MRI-based stereotactic mesencephalotomy was performed at a point 5 mm behind the posterior commissure, 6 mm lateral to and 5 mm below the intercommissural plane using a 2-mm electrode, with the temperature of the electrode raised to $80^{\circ}C$ for 60 seconds. Up until now, the pain has been relatively well-controlled by intermittent intraventricular morphine injection and oral opioids, with the pain level remaining at visual analogue scale 4 or 5. Stereotactic mesencephalotomy with the use of high-resolution MRI and electrophysiologic localization is a valuable procedure in patients with cancer-related facial pain.

Effectiveness of incisions, and Dressing to increase Medical Quality : In Linear or Sigmoid Incisions, and Liquid Wound Dressing for Computer Image Guided Craniotomy (의료품질의 향상을 위한 두피절개 및 드레싱 방법의 개선 효과 분석 : CT영상안내에 의한 직선형 또는 S자형 두피절개와 액상 드레싱효과)

  • Cho, Joon;Eum, Kee-Soo;Lee, Dong-Kue;Park, Keun-Sang;Kim, Mi-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.34 no.4
    • /
    • pp.40-50
    • /
    • 2006
  • The authors aimed to analyze the quality improvement efficiency of wound dressing with 2-octyl cyanoacrylate(2-OCA) in stereotactic image guided linear or sigmoid incisions in a cohort of consecutive craniotomy patients, and to compare clinical results with those of iodine-dressing and silk sutured patients underwent conventional craniotomy surgery with large pedicle flap incisions without stereotactic guidance. In methods, 26 patients were involved as the study group at one hospital. We retrospectively compared their results with those of 38 consecutive control patients at the same unit. The suggested new medical material, 2-octyl cyanoacrylate(2-OCA), resultantly decreased or prevented the contaminated fluid influx from scalp outside. The mean infection rate for the control group (7.89%) was relatively higher than that of the study group (3.85%). In addition, the use of stereotactic image guided craniotomy was significant to reduce operation time, to simplify operative procedures and to decrease potential risk factors.

A Method of Stereotactic Radiosurgery Using A Linear Accelerator (Linear Accelerator를 이용한 Stereotactic Radiosurgery 방법)

  • Na, Soo-Kyung;Park, Jai-Ill
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.146-153
    • /
    • 1994
  • A modified irradiation technique utilizing a linear accelerator for radiation surgery within the brain was performed in 41 cases of patients with anteriovenous malformation(AVM), astrocytoma, meningioma. etc. The treatment planning and dosimetry of small field for stereotactic radiosurgery with 10 MV X-ray isocentically mounted linear accelerator will be presented dose with field size, the central axis persent depth dose and the combined moving beam dose distribution. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor region was perfomed with dose planning computer system(Therac 2300) and was verified with film dosimetry. The more the number of strip and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. In this study, the using machine and method was as fellowing. 1) Apparatus : NELAC-1018 10MV X-ray 2) Strip No. : Select the 5-7 strips 3) Cone and field size are from $1{\times}1cm^2$ to $3.5{\times}3.5cm^2$, and special circular cone designed for the purpose of minimized the risk to normal tissue and those size are $0.7{\~}3.6cm{\phi}$.

  • PDF

Mammography-Guided Interventional Procedure (유방촬영술 유도하 중재 시술)

  • Woo Jung Choi;Hak Hee Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.320-331
    • /
    • 2023
  • Mammography has been the standard screening method for breast cancer. In women with suspicious calcifications and architectural distortion identified on mammography or digital breast tomosynthesis only without detected on breast US, stereotactic biopsy and mammography-guided preoperative localization is one of the method for pathologic diagnosis. This review aims to describe the indication, contraindication, technique of stereotactic biopsy, clip placement after stereotactic biopsy, and digital breast tomosynthesis-guided stereotactic biopsy. In addition, this article reviews mammography-guided preoperative localization using a wire or non-wire device.

Stereotactic Multiplanar Reformatted Computed Tomography-Guided Catheter Placement and Thrombolysis of Spontaneous Intracerebral Hematomas

  • Hwang, Jae-Ha;Han, Jong-Woo;Park, Kyung-Bum;Lee, Chul-Hee;Park, In-Sung;Jung, Jin-Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.185-189
    • /
    • 2008
  • Objective : The authors present their experiences with stereotactic multiplanar reformatted (MPR) computed tomography (CT)-guided catheter placement for thrombolysis of spontaneous intracerebral hematoma (sICH) and their clinical results. Methods : In 23 patients with sICH, MPR CT-guided catheter placement was used to select the trajectory and target point of hematoma drainage. This group was comprised of 11 men and 12 women, and the mean age was 57.5 years (range, 31-79 years). The patients' initial Glasgow Coma Scale scores ranged from 7 to 15 with a median of 11. The volume of the hematoma ranged from 24 mL to 86 mL (mean 44.5 mL). A trajectory along the main axis of the hematoma was considered to be optimal for thrombolytic therapy. The trajectory was calculated from the point of entry through the target point of the hematoma using reformatted images. Results : The hematoma catheter was left in place for a median duration of 48.9 hours (range 34 to 62 hours). In an average of two days, the average residual hematoma volume was 6.2 mL (range 1.4 mL to 10.2 mL) and was reduced by an average of 84.7% (range 71.6% to 96.3%). The residual hematoma at postoperative seven days was less than 5 mL in all patients. There was no treatment-related death during hospitalization. Conclusion : The present study indicates that stereotactic MPR CT-guided catheter placement for thrombolysis is an accurate and safe procedure. We suggest that this procedure for stereotactic removal of sICH should be considered for the optimization of the trajectory selection in the future.