• 제목/요약/키워드: Stereotactic

검색결과 408건 처리시간 0.025초

뇌실주위 배아종 - 증례보고 - (Periventricular Germinoma - Case Report -)

  • 권영이;박봉진;성정남;김영준;조맹기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1245-1249
    • /
    • 2001
  • Germinomas of the central nervous system are rare embryonal tumors(accounting for less than 1% of intracranial neoplasms) that may be located in the pineal region, in the floor of the third ventricle, or in the suprasellar area. We report a case of germinoma developed in periventricular deep white matter without pineal region tumors or suprasellar masses. The 19-year-old male patient presented with slowly progressing headache, dizziness, photophobia, and dysarthria. Initial brain MRI revealed a irregular and dense enhancement from lateral ventricles to 4th ventricle. The stereotactic biopsy of tumor and histologic examination revealed the germinoma. Craniospinal axis radiation therapy was performed. After radiation therapy patient was improved and no neurologic sequelae was seen at discharge. Periventricular germinomas without pineal or suprasellar lesion are very rare. The radiation therapy, as in our case, is beneficial as with other intracranial germinomas. Stereotactic biopsy of periventricular germinoma provides precise pathologic diagnosis and thus allows more specific management.

  • PDF

Comparison of Target Approximation Techniques for Stereotactic Radiosurgical Plan

  • Choi, Kyoung-Sik;Oh, Seong-Jong;Lee, Jeong-Woo;Choe, Bo-Young;Kim, Moon-Chan;Chung, Hyun-Tai;Suh, Tae-Su
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2005년도 제30회 춘계학술대회
    • /
    • pp.47-50
    • /
    • 2005
  • The aim of radiosurgery cures a patient to deliver the lower dose at the normal organ and the higher dose at the tumor. Therefore accuracy of the dose is required to gain effect of radiosurgery in surgical planning. In this paper, we developed the methods of target approximation for a fast treatment planning. Nominally, the stereotactic radiosurgery(SRS) using Linac and Gamma knife produces spherical dose distribution through circular collimators using multiple arcs and 201 holes on semi-spherical helmet by $^{60}Co$. We developed an automatic radiosurgical plan about spherical packing arrangement. To automatically plan the SRS, new planning methods based on cylinder and cube structure for target shaping was developed. This approach using heuristic and stochastic algorithm is a useful radiosurgical plan without restrictions in the various tumor shapes and the different modalities.

  • PDF

전신 정위 방사선 치료시의 적정 조사면 크기 (Optimum Field Size for the Whole Body Stereotactic Radiosurgery)

  • 이병용;민철기;정원규;최은경
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.15-20
    • /
    • 2002
  • 전신 정위 방사선 시술 시 적정 치료 조사면에 대한 연구를 실시하였다. 치료표적 직경이 1cm에서 7cm까지 1cm 간격인 경우에 다양한 크기의 치료 조사면 크기에서 만들어낸 선량 분포를 분석하였다. 치료조사면은 표적 크기에서 -1cm~2cm를 각각 더한 크기로 하였다. 치료 계획의 성적은 TCI(Target Conformity Index)로 표현하였다. 모든 표적 크기에서 -0.5cm~0.5cm를 더한 치료 조사면에서 가장 높은 TCI를 보였다. 6cm 이상의 표적 크기에서는 -0.5cm 또는 0cm를 더한 조사면에서 우수한 성적을 보였으며, 표적 크기 2cm 이하에서는 0cm 또는 0.5cm를 더한 조사면이 좋은 결과를 보였다. 표적 크기와 관계없이 동중심점 선량의 80%~90%에 처방하는 것이 가장 효율적으로 나타났다.

  • PDF

개인용 컴퓨터를 이용한 뇌정위 수술의 정확도의 개선 (The improvement of exactitude of stereotactic surgery based on personal computer)

  • 김준식;박현석;최교환;채의병;이용희;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.275-278
    • /
    • 1996
  • Accuracy and reproducibility of coordinates, angles/areas and volume measurements are the mai goal of imaging-guided stereotactic systems. Errors in measurements are due to pitfalls in a present systems. Factors responsible for inaccuracy and variability on measurements are inappropriate display window settings, unequal spatial resolution, display/film distortion, inappropriate slice width, lack of isocentricity between gantry and frame, and nonparallelism between frame and scanning plan. The most important factor responsible for errors when using stereotactic frames is the nonparallel relationship to the plane of scanning. For the solution of above problem, author developed a computer program for the measurement of the coordinates of intracerebral target, which is operated using the personal computer. This program can calculate the actual spatial coordinates regardless of the inappropriate parallelism between frame and scanning plane and decrease the range of errors of measurements.

  • PDF

Stereotactic Radiosurgery

  • Chung, Hyun-Tai;Lee, Dong-Joon
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.63-70
    • /
    • 2020
  • Stereotactic radiosurgery is one of the most sophisticated forms of modern advanced radiation therapy. Unlike conventional fractionated radiotherapy, stereotactic radiosurgery uses a high dose of radiation with steep gradient precisely delivered to target lesions. Lars Leksell presented the principle of radiosurgery in 1951. Gamma Knife® (GK) is the first radiosurgery device used in clinics, and the first patient was treated in the winter of 1967. The first GK unit had 179 cobalt 60 sources distributed on a hemispherical surface. A patient could move only in a single direction. Treatment planning was performed manually and took more than a day. The latest model, Gamma Knife® IconTM, shares the same principle but has many new dazzling characteristics. In this article, first, a brief history of radiosurgery was described. Then, the physical properties of modern radiosurgery machines and physicists' endeavors to assure the quality of radiosurgery were described. Intrinsic characteristics of modern radiosurgery devices such as small fields, steep dose distribution producing sharp penumbra, and multi-directionality of the beam were reviewed together with the techniques to assess the accuracy of these devices. The reference conditions and principles of GK dosimetry given in the most recent international standard protocol, International Atomic Energy Agency TRS 483, were shortly reviewed, and several points needing careful revisions were highlighted. Understanding the principles and physics of radiosurgery will be helpful for modern medical physicists.

Stereotactic Radiation Therapy for Nasal Carcinoma with Cribriform Plate Destruction in Three Dogs: A Serial CT Study

  • Soyon An;Gunha Hwang;Moonyeong Choi;Chan Huh;Young-Min Yoon;Hee Chun Lee;Tae Sung Hwang
    • 한국임상수의학회지
    • /
    • 제40권2호
    • /
    • pp.139-146
    • /
    • 2023
  • Three dogs were referred with epistaxis and facial deformity. Computed tomography (CT) scan identified masses in the bilateral nasal cavity with soft tissue attenuation and contrast enhancement. These masses had caused adjacent bones lysis, especially lysis of cribriform plate that extended to the intracranial region. Base on histopathology and CT imaging results, tumors were diagnosed as nasal carcinomas at stage 4. Three dogs were treated with stereotactic radiation therapy (SRT). These dogs received 30-35 Gy from 3-5 daily treatments (7-10 Gy per treatment). The sizes of tumors decreased the most on follow-up CT images at one month after treatment. Recurrence was confirmed between 3 and 5 months after completing SRT. The survival time of dogs treated with SRT were 110, 190, and 210 days, respectively. This study confirmed that SRT could treat canine nasal carcinomas with cribriform plate lysis without causing serious radiation toxicities. Follow-up CT examination is considered at 1 month and 3 to 6 months after SRT to accurately evaluate the prognosis and the timing of recurrence.

고에너지 선형가속기에 의한 입체방사선수술의 선량특성 (Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam)

  • 최태진;김옥배
    • Radiation Oncology Journal
    • /
    • 제10권2호
    • /
    • pp.137-145
    • /
    • 1992
  • 전산화단층촬영에 근거를 둔 3차원선량계산은 소형의 뇌종양에 대한 방사선수술에 있어서 가장 기본이 된다. 본 연구의 방사선수술 프로그램은 전산화단층촬영을 통해 표적 위치, 크기와 모양을 3차원공간에서 결정하고 최적조사면적을 구할 수 있었다. 방사선수술의 선량은 선형가속기의 6메가볼트 고에너지 광자선을 이중 비공면의 회전조사를 가상두부에 실시하여 계산된 3차원적 선량분포와 필름선량계의 실측선량을 비교한 바 거의 일치됨을 확인하였다. 본 연구의 방사선수술에서 $80\%$에서 $50\%$까지 선량곡선의 기울기는 전회전각이 1120도 일때 10 mm 조사면적에서 약 $16.7\%$/mm 였고 30 mm 에서 는 $13.0\%$/mm를 보였다. 또한 표적 주위의 선량분포는 표적내 최대선량값이 $90\%$ 에서 $50\%$ 까지 선량분포의 최대폭은 직경 10 mm조사면에서 2.3 mm를 나타내었으며, $90\%$에서 $20\%$까지의 거리는 5.6 mm를 나타내었으며, 30 mm직경의 조사면에서는 각각 3.5 mm와 9.8 mm를 보였다. 이러한 선량분포의 급격한 기울기는 방사선수술시 표적주위의 치명부위의 손상을 최소화하기 위한 선량최적화 작업에 지침이 될 것으로 생각되며, 또한 방사선수술방법의 차이에 따라 비교자료가 될 수 있을 것으로 생각된다.

  • PDF

정위적 방사선 수술에서 물팬텀을 이용한 목표점 및 전달 선량확인 (Target Localization and Dose Delivery Verification used a Water Phantom in Stereotactic Radiosurgery)

  • 강영남;이동준;권수일;권양
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.19-28
    • /
    • 1996
  • 정위적 방사선수술 (Stereotactic radiosurgery) 은 병소(region)의 위치를 정확히 결정하고 치료에 요구되는 방사선량이 정확히 전달되는 것이 중요하다. 본 연구는 이를 실험적으로 확인할 목적으로 특별히 고안된 물팬텀 (water phantom)을 개발하여 Leksell 정위기구 (Leksell Stereotactic Frame; LSF)에 부착하여 방사선수술을 시행하였다. 방사선 수술에는 Leksell 감마나이프 (Gamma Knife Unit; GKU) 와 LSF를 사용하였으며 실험을 위해 개발된 팬텀은 1mm 두께 플라스틱의 직경 160mm의 구형으로 물을 채울수 있는 구조로 되어있다. 측정장치로서는 목표점 설정(target localization)을 위한 필름과 전달 선량(dose delivery) 측정을 위해 이온 전리함(ionchamber) 을 사용하였으며 이를 팬텀의 목표점에 각각 위치시킬 수 있도록 설계하였다. 본 연구에서 목표점 확인은 허용 오차범위인 $\pm$0.5 mm 이내에서의 값을 보였으며 선량전달값은 $\pm$3% 정도의 오차로 허용값내에 있음을 보여주었다. 본 연구에서 개발된 팬텀으로 측정된 값이 모두 허용 오차범위 내에 있음을 보여주었고 이로인해 GKU 및 LSF의 주기적 QA(Quality Assurance)에 계속적으로 사용할수 있게 되었다.

  • PDF

선형 가속기를 이용한 정위적 방사선 수술시 병소내 선량분포의 특성조사 (Search of Characteristic for Dose Distribution Presented by Multi­isocentric Stereotactic Radiosurgical Plan Using Linear Accelerator)

  • 최경식;오승종;이형구;최보영;전흥재;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권4호
    • /
    • pp.225-233
    • /
    • 2003
  • 방사선 치료 계획의 목적은 정상 조직 부근에서는 최소한의 방사선 조사가 되는 동안 병소에는 동일한 선량이 조사되는 것이다. 선형가속기를 이용한 정위적 방사선 수술시 단일한 구형의 선량분포는 병소에 대하여 균등한 선량분포를 이루고, 병소 내에는 70% 이상의 고선량이 등선량 곡선내에 포함되면서 주위 정상조직에서는 급격히 낮은 선량을 가지게 한다. 또한 이와 같은 방법은 감마나이프를 이용한 정위적 방사선 수술의 경우와 비슷한 치료 계획을 나타낸다. 이처럼 정위적 방사선 수술시 이용되는 구형의 선량분포를 가지는 isocenter는 실제 방사선 수술 계획시 많은 시간과 경험을 바탕으로 수술 계획자에 의해 병소 내에 배치되어 진다. 본 연구는 효율적인 방사선 수술이 수행되도록 수술 계획시 구형 선량분포에 관여하는 빔관련 변수들을 고려하여 병소내 선량분포의 특성을 조사하였다. 이를 위해 불규칙한 형태의 병소를 직육면체형과 원통형으로 가정하여 비교하였고, 동일한 체적의 병소 모델에 대하여 빔관련 변수를 변화시켜 구형 선량분포를 이루는 isocenter들의 위치 및 콜리메이터의 크기를 달리하면서 병소 모델에 대한 선량 분포를 얻었다. 이때, 얻어진 선량분포 Dose Profile과 Dose Volume Histogram (DVH)으로 비교한 결과, 불규칙한 모양의 병소에 대하여 콜리메이터의 크기와 Isocenter의 개수, Isocenter의 간격 등의 빔관련 변수를 최적화함으로서 더 나은 고선량의 등선량 곡선(Isodose Curve)내에 병소를 포함시킬 수 있었다. 이러한 병소내 구형 선량 분포를 가지는 isocenter의 배치에 따른 특성들은 정위적 방사선 수술 계획시 더 효율적이면서, 빠른 수술 계획을 수립하는데 많은 도움이 될 것으로 사료된다.

  • PDF

정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구 (Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery)

  • 윤형근;신교철;김영식
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.89-94
    • /
    • 1998
  • 자기공명영상을 정위적 방사선 수술에 이용하기 위한 우선 과제로 비교적 균일한 phantom에서 자기공명영상으로 구한 정위적 표적점이 실제 방사선수술시의 방사선 빔의 isocenter와 일치하는지 확인하고자 하였다. 무 속에 임의의 표적점이 표시된 선량측정용 필름을 끼우고 head ring 을 고정시킨 다음 자기공명영상올 얻어 방사선 수술용 planning computer 로 표적점의 정위적 좌표를 구한 다음 실제 치료와 같이 무 phantom 을 테이블에 고정한 후 구해진 표적점의 좌표를 isocenter로 하여 방사선을 조사하고 필름을 현상하여 필름에 표시한 표적점과 실제 방사선이 조사된 부위의 선량분포의 중심을 비교하였는데 오차가 0.5 mm 이내였다. 따라서 무와 같은 비교적 균일한 phantom 에서는 표적점과 실제 방사선이 조사된 부위의 선량분포의 중심이 잘 일치함을 알 수 있었다. 또 다른 방법으로 자기공명영상의 왜곡의 정도를 직접 확인하기 위해서 아크릴에 1 cm 간격으로 구멍을 뚫고 오일방울을 넣어준 후 아크릴 phantom을 무 속에 수평과 수직방향으로 삽입한 뒤 자기공명영상을 얻은 후 각각의 좌표를 구하여 자기공명영상의 수평과 수직방향에서 왜곡의 정도를 측정하였다. 결과는 균일한 물질 내에서는 7 cm 거리에서 0.4 mm 이내의 오차를 보여서 비교적 잘 일치하였다. 그런데 이 측정과정에서 device 자체와 digitizing 과정의 오차가 있는 것으로 판단되므로 더 정교한 device 의 제작이 필요한 것으로 생각된다.

  • PDF