• Title/Summary/Keyword: Stereo balance

Search Result 8, Processing Time 0.028 seconds

Efficient and Robust Correspondence Detection between Unbalanced Stereo Images

  • Kim, Yong-Ho;Kim, Jong-Su;Lee, Sangkeun;Choi, Jong-Soo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.3
    • /
    • pp.161-170
    • /
    • 2012
  • This paper presents an efficient and robust approach for determining the correspondence between unbalanced stereo images. The disparity vectors were used instead of feature points, such as corners, to calculate a correspondence relationship. For a faster and optimal estimation, the vectors were classified into several regions, and the homography of each region was calculated using the RANSAC algorithm. The correspondence image was calculated from the images transformed by each homography. Although it provided good results under normal conditions, it was difficult to obtain reliable results in an unbalanced stereo pair. Therefore, a balancing method is also proposed to minimize the unbalance effects using the histogram specification and structural similarity index. The experimental results showed that the proposed approach outperformed the baseline algorithms with respect to the speed and peak-signal-to-noise ratio. This work can be applied to practical fields including 3D depth map acquisition, fast stereo coding, 2D-to-3D conversion, etc.

  • PDF

MSBS-SPR Integrated System Allowing Wider Controllable Range for Effective Wind Tunnel Test

  • Sung, Yeol-Hun;Lee, Dong-Kyu;Han, Jong-Seob;Kim, Ho-Young;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.414-424
    • /
    • 2017
  • This paper introduces an experimental device which can measure accurate aerodynamic forces without support interference in wide experimental region for wind tunnel test of micro aerial vehicles (MAVs). A stereo pattern recognition (SPR) method was introduced to a magnetic suspension and balance system (MSBS), which can eliminate support interference by levitating the experimental model, to establish wider experimental region; thereby MSBS-SPR integrated system was developed. The SPR method is non-contact, highly accurate three-dimensional position measurement method providing wide measurement range. To evaluate the system performance, a series of performance evaluations including SPR system measurement accuracy and 6 degrees of freedom (DOFs) position/attitude control of the MAV model were conducted. This newly developed system could control the MAV model rapidly and accurately within almost 60mm for translational DOFs and 40deg for rotational DOFs inside of $300{\times}300mm$ test section. In addition, a static wind tunnel test was conducted to verify the aerodynamic force measurement capability. It turned out that this system could accurately measure the aerodynamic forces in low Reynolds number, even for the weak forces which were hard to measure using typical balance system, without making any mechanical contact with the MAV model.

Fast Approach for Stereo Balancing Mapping Function

  • Kim, J.S.;Lee, S.K.;Kim, T.Y.;Lee, J.Y.;Choi, J.S.
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.286-289
    • /
    • 2009
  • This paper presents an effective approach to minimize recursive computations for balancing stereo pairs by using disparity vector errors and its directional histogram. A stereo balancing function is computed from the correspondent pixels between two images, and a simple approach is to find the matching blocks of two images. However, this procedure requires recursive operation, and its computation cost is very high. Therefore, in this paper, we propose an efficient balance method using structural similarity index and a partial re-searching scheme to reduce the computation cost considerably. For this purpose, we determine if re-searching for each block is necessary or not by using the errors and the directional histogram of disparity vectors. Experiment results show that the performance of the proposed approach can save the computations significantly with ignorable image quality degradation compared with full re-search approach.

  • PDF

Evaluation of orthodontics for treating temporo-mandibular joint disorders using a stereo camera (스테레오 카메라를 이용한 측두하악관절 교정장치(NO SICK)의 성능 평가)

  • Yun, Hong-Ii;Park, Joon-Su;Chung, Koo-Yeong;Shin, Ki-Young;Park, Joon-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.5
    • /
    • pp.359-366
    • /
    • 2015
  • TMJ(TemporoMandibular Joint) is considered as the most important articulation in human body for maintaining the balance. Thus it is one of the main treatment areas in Chiropractic. Instead of Chiropractic treatment, NOSICK, a TMJ balancing device, can be used. As there is no such device to quantify the effect of NOSICK, a system was developed to measure the effect of NOSICK. This system is composed of stereo vision, infrared lights, and infrared through filter, etc. It requires optical markers for the measurement. 8 land markers were selected from the face which will show different displacement as NOSICK is applied. 11 test subjects were measured with the system developed with and without NOSICK applied. Quantifiable displacement of markers before and after applying NOSICK was successfully measured with the system developed.

Objects Tracking of the Mobile Robot Using the Hybrid Visual Servoing (혼합 비주얼 서보잉을 통한 모바일 로봇의 물체 추종)

  • Park, Kang-IL;Woo, Chang-Jun;Lee, Jangmyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.781-787
    • /
    • 2015
  • This paper proposes a hybrid visual servoing algorithm for the object tracking by a mobile robot with the stereo camera. The mobile robot with the stereo camera performs an object recognition and object tracking using the SIFT and CAMSHIFT algorithms for the hybrid visual servoing. The CAMSHIFT algorithm using stereo camera images has been used to obtain the three-dimensional position and orientation of the mobile robot. With the hybrid visual servoing, a stable balance control has been realized by a control system which calculates a desired angle of the center of gravity whose location depends on variations of link rotation angles of the manipulator. A PID controller algorithm has adopted in this research for the control of the manipulator since the algorithm is simple to design and it does not require unnecessary complex dynamics. To demonstrate the control performance of the hybrid visual servoing, real experiments are performed using the mobile manipulator system developed for this research.

Stereo Vision Based Balancing System Results

  • Tserendondog, Tengis;Amar, Batmunkh;Ragchaa, Byambajav
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Keeping a system in stable state is one of the important issues of control theory. The main goal of our basic research is stability of unmanned aerial vehicle (quadrotor). This type of system uses a variety of sensors to stabilize. In control theory and automatic control system to stabilize any system it is need to apply feedback control based on information from sensors. Our aim is to provide balance based on the 3D spatial information in real time. We used PID control method for stabilization of a seesaw balancing system and the article presents our experimental results. This paper presents the possibility of balancing of seesaw system based on feedback information from stereo vision system only.

An Objective Performance Analysis of Crosstalk Cancellation Scheme for Sound Rendering Systems Based on Listener Position Tracking (청취자 위치정보 기반 Sound Rendering 시스템 상호간섭 제거기법의 객관적 성능분석)

  • Lee, Jung-Hyuck;Kim, Yeong-Moon;Yoo, Seung-Soo;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2C
    • /
    • pp.112-118
    • /
    • 2011
  • In this paper, we conduct an objective performance analysis of the crosstalk cancellation scheme studied in [11]. While the conventional scheme is only applicable to a listener on the optimal listenable region (sweetspot), the space skew/crosstalk cancellation (SS/CC) scheme in [11] can mitigate crosstalk regardless of the listener's position by using listener position tracking (LPT) system. The SS/CC scheme is composed of two parts: LPT-based SS and CC parts. In this paper, the SS/CC scheme is evaluated by some criteria such as follows: condition number, and the balance characteristic, its root mean square error, and running average.

Novel pH/Temperature Sensitive Hydrogels of Poly (ethylene glycol)-Poly (caprolactone) -Poly (${\beta}-amino\;ester$) (PAE-PCLA-PEGPCLA-PAE) Biodegradable Polyester Block Copolymer

  • Huynh Dai Phu;Lee Doo-Sung
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.263-263
    • /
    • 2006
  • Poly (ethylene glycol)(PEG) - Poly (${\varepsilon}-caprolactone(CL)$) - Poly (D,L lactide(LA) (PCLA-PEG-PCLA) was synthesized by ring-opening polymerization to form temperature sensitive hydrogel triblock copolymer. The triblock copolymer was acrylated by acryloyl chloride. ${\beta}-amino$ ester was used as a pH sensitive moiety, in this study ${\beta}$- amino ester obtained from 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine, it have pKb around 6.6. pH/temperature sensitive penta-block copolymer (PAE-PCL-PEG-PCL-PAE) was synthesized by addition polymerization from acrylated triblock copolymer, 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine. Their physicochemical properties of triblock and penta-block copolymers were characterized by $^1H-NMR$ spectroscopy and gel permeation spectroscopy. Sol-gel phase transition behavior of PAE-PCL-PEG-PCL-PAE block copolymers were investigated by remains stable method. Aqueous media of the penta-block copolymer (at 20 wt%) changed from a sol phase at pH 6.4 and $10^{\circ}C$ to a gel phase at pH 7.4 and $37^{\circ}C$. The sol-gel transition properties of these block copolymers are influenced by the hydrophobic/hydrophilic balance of the copolymers, block length, hydrophobicity, stereo-regularity of the hydrophobic of the block copolymer, and the ionization of the pH function groups in the copolymer depended on the changing of environmental pH, respectively. The degradation and the stabilization at pH 7.4 and $37^{\circ}C$, and the stabilization at pH 6.4 and $10^{\circ}C,\;5^{\circ}C,\;0^{\circ}C$, of the gel were determined. The results of toxicity experiment show that the penta block copolymer can be used for injection drug delivery system. The sol?gel transition of this block copolymer also study by in vitro test ($200{\mu}l$ aqueous solution at 20wt% polymer was injected to mouse). Insulin loading and releasing by in vitro test was investigated, the results showed that insulin can loading easily into polymer matrix and release time is around 14-16days. The PAE-PCL-PEG-PCL-PAE can be used as biomaterial for drug, protein, gene loading and delivery.

  • PDF