• Title/Summary/Keyword: Stereo X-ray

Search Result 35, Processing Time 0.061 seconds

3D Inspection by Registration of CT and Dual X-ray Images

  • Kim, Youngjun;Kim, Wontae;Lee, Deukhee
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.16-21
    • /
    • 2016
  • Computed tomography (CT) can completely digitize the interior and the exterior of nearly any object without any destruction. Generally, the resolution for industrial CT is below a few microns. The industrial CT scanning, however, has a limitation because it requires long measuring and processing time. Whereas, 2D X-ray imaging is fast. In this paper, we propose a novel concept of 3D non-destructive inspection technique using the advantages of both micro-CT and dual X-ray images. After registering the master object’s CT data and the sample objects’ dual X-ray images, 3D non-destructive inspection is possible by analyzing the matching results. Calculation for the registration is accelerated by parallel computing using graphics processing unit (GPU).

Study of a coronal jet observed by Hinode, SDO, and STEREO

  • Lee, Gyeong-Seon;Innes, Davina;Mun, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.35.2-35.2
    • /
    • 2011
  • We have investigated a coronal jet near the limb on 2010 June 27 by Hinode/X-Ray Telescope (XRT), EUV Imaging Spectrograph (EIS), SDO/Atmospheric Imaging Assembly (AIA), and STEREO. From EUV (AIA and EIS) and soft X-ray (XRT) images we identify the erupting jet feature in cool and hot temperatures. Using the high temporal and multi wavelength AIA images, we found that the hot jet preceded its associated cool jet and their structures are well consistent with the numerical simulation of the emerging flux-reconnection model. From the spectroscopic analysis, we found that the jet structure changes from blue shift to red one with time, which may indicate the helical structure of the jet. The STEREO observation, which enables us to observe this jet on the disk, shows that there was a dim loop associated with the jet. On the other hand, we found that the structure of its associated active region seen in STEREO is similar to that in AIA observed 5 days before. Based on this fact, we compared the jet morphology on the limb with the magnectic fields extrapolated from a HMI vector magnetogram of this active region observed on the disk. Interestingly, the comparison shows that the open and closed magnetic field configuration correspond to the jet and the dim loop, respectively, as the Shibata's jet model predicted.

  • PDF

Mass constraints of coronal mass ejection plasmas observed in EUV and X-ray passbands

  • Lee, Jin-Yi;Raymond, John C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.39.1-39.1
    • /
    • 2011
  • Coronal mass ejection (CME) plasmas have been observed in EUV and X-ray passbands as well as in white light. Mass of CME has been determined using polarized brightness observed by the Large Angle and Spectrometric Coronagraph Experiment (LASCO) on board Solar and Heliospheric Observatory (SOHO). Therefore, this mass obtained from the LASCO observation indicates the total CME mass. However, the mass of CME plasma in different temperatures can be determined in EUV and X-ray passbands using observations by SOHO/EIT, STEREO/EUVI, and Hinode/XRT. Prominence/CME plasmas have been observed as absorption or emission features in EUV and X-ray passbands. The absorption features provide a lower limit to cold mass. In addition, the emission features provide an upper limit to the mass of plasmas in temperature ranges of EUV and X-ray. We determine the mass constraints using the emission measure obtained by assuming the prominence/CME structures. This work will address the mass constraints of hot and cold plasmas in CMEs, comparing to total CME mass.

  • PDF

3-D Structure of a Coronal Jet Seen in Hinode, SDO, and STEREO

  • Lee, Kyoung-Sun;Innes, Davina;Moon, Yong-Jae;Shibata, Kazunari
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • We have investigated a coronal jet near the limb on 2010 June 27 by Hinode/X-Ray Telescope (XRT), EUV Imaging Spectrograph (EIS), Solar Optical Telescope (SOT), SDO/Atmospheric Imaging Assembly (AIA), and STEREO. From EUV (AIA and EIS) and soft X-ray (XRT) images we identify the erupting jet feature in cool and hot temperatures. It is noted that there was a small loop eruption in Ca II images of the SOT before the jet eruption. Using high temporal and multi wavelength AIA images, we found that the hot jet preceded its associated cool jet. The jet also shows helical-like structures during the rising period. According to the spectroscopic analysis, the jet structure changes from blue shift to red one with time, implying the helical structure of the jet. The STEREO observation, which enables us to observe this jet on the disk, shows that there was a dim loop associated with the jet. Comparing the observations from the AIA and STEREO, the dim loop corresponds to the jet structure which implies the heated loop. Considering that the structure of its associated active region seen in STEREO is similar to that in AIA observed 5 days before, we compared the jet morphology on the limb with the magnetic fields extrapolated from a HMI vector magnetogram observed on the disk. Interestingly, the comparison shows that the open field corresponds to the jet which is seen as the dim loop in STEREO. Our observations (XRT, SDO, SOT, and STEREO) are well consistent with the numerical simulation of the emerging flux reconnection model.

  • PDF

Moreton Wave and EUV Wave Associated with the 2010 February 7 and 2010 August 18 Flares

  • Asai, Ayumi;Isobe, Hiroaki;Takasao, Shinsuke;Shibata, Kazunari
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.83.1-83.1
    • /
    • 2011
  • Solar flares are very spectacular, and are associated with various phenomena. Coronal shocks or disturbances are one of such flare-related phenomena. Although Moreton waves and X-ray waves are well explained with MHD first mode shocks propagating in the corona, there still remains a big problem on the nature of the waves, since they are very rare phenomena. On the other hand, EIT waves (or EUV waves) have been paid attention to as another phenomenon of coronal disturbances. However, the physical features (velocity, opening angle, and so on) are much different from those for Moreton waves and X-ray waves. We report detailed features of the coronal disturbances associated with the 2010 February 7 and the 2010 August 18 flares. For the former flare we analyzed the H-alpha images obtained by SMART at Hida Observatory, Kyoto University, Japan and by a flare telescope at National Astronomical Observatory of Japan, the X-rays images taken by Hinode/XRT, and the EUV images obtained by the both satellites of STEREO, and found the Moreton wave, X-ray wave, and EIT wave, simultaneously. In the latter flare, on the other hand, we observed a very fast EUV wave in EUV images taken by SDO/AIA. The propagating speed is comparable to the MHD first mode wave, while there is no obvious evidence of shocks for this flare. From these results, we discuss the nature of coronal disturbances.

  • PDF

Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed (응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발)

  • Lim, Woo-Taek;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

The Reconstruction of the Stereo X-ray Image for Overlay Objects (중첩 물체에 대한 스테레오 X-선 영상의 3차원 형상복원)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Park, Jong-Won
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.656-659
    • /
    • 2011
  • X-선 검색장치는 대상체의 단면을 스캔하여 결과를 확인하기 때문에 정확성이 낮다는 것이 문제점으로 지적되어왔다. 이를 개선하기 위하여 선행연구로 스테레오 X-선 검색장치를 개발하여 단일 대상체에 대하여 윤곽선 정합 및 볼륨기반 형상복원 연구를 수행하였다. 본 연구에서는 스테레오 X-선 검색장치를 이용하여 두 개의 중첩된 대상체를 스캔하여 형상을 분리 복원하기 위한 연구를 진행하였다. 중첩 대상체에 대한 분리 복원을 위해 벡터정보의 거리값을 계산하여 내 외부 복셀을 분리하고 중첩부분에 대한 제거는 Z축을 기준으로 임계치를 두어 분리하는 알고리즘을 제안하였다. 3차원 스테레오 X-선 검색장치에 대한 스캔영상의 형상복원 알고리즘 개선을 통해 제한된 스캔환경에서 집적화된 대상체의 검색을 가능하도록 할 것이다.

  • PDF

The Numerical Phantom Design for Simulation of the Stereo X-ray Inspection System (스테레오 X-선 투시장치 전산 모사를 위한 수치적 팬텀 설계)

  • Hwang, Young-Gwan;Lee, Seung-Wook;Lee, Nam-Ho;Moon, Myung-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1915_1916
    • /
    • 2009
  • 스테레오 X-선 영상시스템 개발을 위하여 수치적 프로젝션을 획득하는 방법론 및 수치적 팬텀 영상을 고안하고 시험하였다. 오픈소스인 TAKE21을 사용하여 수치적 팬텀을 설계하고 그로부터 프로젝션 이미지를 획득하였다. 스테레오 영상을 위한 평행 원근 투영(Parallel-Perspective) 기하구조에 대한 스테레오 프로젝션 영상을 얻기 위해서 계측기의 계와 선원의 위치에 대해 동차 좌표계(Homogeneous coordinate)에서의 선형변환(Linear Transform)을 적용되는 방식을 이용하였다. 이러한 시뮬레이션은 스테레오 X-선 검색 장치의 설계 및 알고리즘 개발에 유용하게 사용될 수 있을 것이다.

  • PDF

A study on a real-time 3D Viewer using the stereo X-ray Search device (스테레오 X-선 검색장치를 이용한 실시간 3D Viewer에 관한 연구)

  • Lee, Seung-Min;Cho, Han-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1335-1336
    • /
    • 2015
  • 스테레오 X-선 검색장치에서 취득된 2장의 영상을 통하여 얻어질 수 있는 3차원 정보의 한계를 극복하기 위하여 취득된 영상에 대하여 간단한 전처리 및 시점을 변환하여 실시간으로 3D 출력하여 관측자로 하여금 상당한 입체감을 느낄 수 있게 할 수 있는 기법을 제시하였으며, 본 연구의 결과는 실시간 스테레오 X-선 검색장치의 효율을 높이는데, 주요하게 활용될 수 있을 것으로 예상된다. 따라서, 본 연구에서는 기존 좌, 우 프레임 병합 출력을 연속 프레임 120Hz 출력으로 개선하고, 입체감 인지 시간을 줄이기 위하여 초기 영상을 제공하였다.

  • PDF

Simple Algorithm of Structure Features Extration for Stereo Image Matching (스테레오 영상 정합을 위한 새로운 구조 정보 추출 알고리즘)

  • 최환언
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 1991
  • In this reseach, double-layered photoconductor consist of the carrier generation layer(CGL) of $\varepsilon$ type copper phthalocyanine thin film by an aqueous coating method and the carrier transport layer(CGL) of polyvinyl carbazol(PVK) by spin coating. We inverstigated effect of the surfactant solution and cathod electrolysis to the crystal type of $\varepsilon$-CuPc in CGL with TEM, SEM and X- ray diffraction spectroscopy and studied the mechanism of an aqueous coating for the preparation of CGL. The effect of the washing of CGL about the electrophotographic characteristics of the $\varepsilon$-CuPc/PVK doublelayered photoconductors is studied also.

  • PDF