• Title/Summary/Keyword: Step-up

Search Result 2,375, Processing Time 0.027 seconds

Interrupting characteristics of the transformer superconducting fault current limiter

  • Hwang, S.H.;Choi, H.W.;Jeong, I.S.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.4
    • /
    • pp.40-44
    • /
    • 2017
  • This paper analyzed the fault current limiting characteristics of the previously proposed transformer superconducting fault current limiter (TSFCL) interruption system according to its transformer type. The TSFCL interruption system is an interruption technology that combines a TSFCL, which uses a transformer and a superconductor, and a mechanical DC circuit breaker. This technology first limits the fault current using the inductance of the transformer winding and the quench characteristics of the superconductor. The limited fault current is then interrupted by a mechanical DC circuit breaker. The magnitude of the limited fault current can be controlled by the quench resistance of the superconductor in the TSFCL and the turns ratio of the transformer. When the fault current is controlled using a superconductor, additional costs are incurred due to the cooling vessel and the length of the superconductor. When the fault current is controlled using step-up and step-down transformers, however, it is possible to control the fault current more economically than using the superconductor. The TSFCL interruption system was designed using PSCAD/EMTDC-based analysis software, and the fault current limiting characteristics according to the type of the transformer were analyzed. The turns ratios of the step-up and step-down transformers were set to 1:2 and 2:1. The results were compared with those of a transformer with a 1:1 turns ratio.

Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier

  • Zhang, Lu;Ge, Hong-juan;Jiang, Fan;Yang, Guang;Lin, Yi
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1536-1544
    • /
    • 2018
  • The existing 24-pulse autotransformer rectifier unit (ATRU) needs interphase reactors for parallel work of the rectifier bridges, and its output voltage cannot be regulated. Aiming at these problems, a step-up and step-down asymmetrical 24-pulse ATRU is proposed in this paper. The connections and turns ratios among transformer windings are well designed. In addition, a 15-degree phase difference is formed between two of the 24 voltage vectors produced by the transformer, which makes the four rectifier bridge groups produce a 24-pulse DC voltage without interphase reactors. Meanwhile, by adding extended winding to each phase of the transformer, wide-range regulation of the ATRU output voltage can be realized, and the reasonable voltage regulation range is between 0.2 and 1.6. The superposition of the voltage vectors and the principle of the voltage regulation are analyzed in detail. Furthermore, the turns ratio of the windings, winding current, output voltage, and kilovolt-ampere rating are all derived. Finally, the simulations and experiments are carried out, and the correctness of the principle and theoretical analysis of the new 24-pulse ATRU are verified.

A Wide Voltage-Gain Range Asymmetric H-Bridge Bidirectional DC-DC Converter with a Common Ground for Energy Storage Systems

  • Zhang, Yun;Gao, Yongping;Li, Jing;Sumner, Mark
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.343-355
    • /
    • 2018
  • A wide-voltage-conversion range bidirectional DC-DC converter is proposed in this paper. The topology is comprised of one typical LC energy storage component and a special common grounded asymmetric H-bridge with four active power switches/anti-parallel diodes. The narrow output PWM voltage is generated from the voltage difference between two normal (wider) output PWM voltages from the asymmetric H-bridge with duty cycles close to 0.5. The equivalent switching frequency of the output PWM voltage is double the actual switching frequency, and a wide step-down/step-up ratio range is achieved. A 300W prototype has been constructed to validate the feasibility and effectiveness of the proposed bidirectional converter between the variable low voltage side (24V~48V) and the constant high voltage side (200V). The slave active power switches allow ZVS turn-on and turn-off without requiring any extra hardware. The maximum conversion efficiency is 94.7% in the step-down mode and 93.5% in the step-up mode. Therefore, the proposed bidirectional topology with a common ground is suitable for energy storage systems such as renewable power generation systems and electric vehicles with a hybrid energy source.

Effects of Cryogenic Treatment on Residual Stress and Tensile Properties for 6061 Al Alloy (극저온 열처리 공정이 6061 알루미늄 합금의 잔류응력과 인장특성에 미치는 영향)

  • Park, Kijung;Ko, Dea Hoon;Kim, Byung Min;Lim, Hak Jin;Lee, Jung Min;Cho, Young-Rae
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • To develop a 6061 aluminum alloy with low residual stress and high tensile strength, a cryogenic treatment process was investigated. Compared to the conventional heat treatment process for precipitation hardening with artificial aging, the cryogenic treatment process has two additional steps. The first step is cryogenic quenching of the sample into liquid nitrogen, the second step is up-hill quenching of the sample into boiling water. The residual stress for the sample was measured by the $sin^2{\psi}$ method with X-ray diffraction. The 6061 aluminum alloy sample showed 67% relief in stress at the cryogenic treatment process with artificial aging at $175^{\circ}C$. From this study, it was found that the optimum cryogenic treatment process for a sample with low residual stress and high tensile strength is relatively low cooling speed in the cryogenic quenching step and a very high heating speed in the up-hill quenching step.

Case Analysis for the Development of Smart Factory ISP Indicators

  • Heon-Wook Lim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.3
    • /
    • pp.321-326
    • /
    • 2023
  • The purpose of this study is to create and present a formalized module of ISP (Information Strategy Plan), a smart factory consulting method that is helpful to companies or consultants who will build smart factories. Order of study is First, the theoretical research direction is established through the investigation of related papers. Second, ISP policy research practices are compared to derive practical implementation methods. Third, in order to derive a standardized module method related to the final smart factory ISP, related cases of the government and individuals are compared. As a result of previous research, ISP (Information Strategy Planning), a consulting methodology, is similar to Deming's PDCA, and is regarded as Plan (environment and current status analysis), Do (establishment of future model goals), Check (establishment of implementation plan), and Act (follow-up management). As a result of the study, we obtained the following results. The first step is to analyze the current status and identify the purpose of introduction and problems in plant operation. In the second step, establish a consulting plan and derive a proposal description, strategic task, and master plan. Step 3 establishes detailed action plans, evaluates consulting outputs and consulting, and reports performance. Step 4 is established as follow-up management consulting. The limitation of the study is that although related data were compared to develop the consulting methodology into a standardized module, FGI analysis through experts or Delphi survey were not conducted, so there is a limit to the reliability of the mapping results.

Lesson Design of Upper Secondary Home Economics education (고등학교에서의 가정과교육 -고등학교 가정과 단시수업 설계- (1990년도 제 2차 학술대회))

  • 전귀연;서영숙
    • Journal of Korean Home Economics Education Association
    • /
    • v.2 no.1
    • /
    • pp.123-142
    • /
    • 1990
  • The aim of this study is to apply lesson design of high school home economics to model which consists of six steps of instructional procedure among various models for instructional design, Through thesis, central content of each step was written as follows; 1) At the step of establishment of terminal instructional objectives, educational objectives, terminal instructional objectives was analyzed and specific instructional objectives was extracted. 3) At the step of diagnosis of entering behavior, ability of prior learning and ability of preliminary learning were evaluated, which was used as establishing instructional strategy and doing individual guidance. 4)At the step of determining instructional strategy, instructional strategy should be extracted by considering instructional event which is adequate to content of instruction. Instructional strategy consists of five main factor, factors, those are, activity of introduction of instruction, presentation of content of instruction and information, participation of learner and learning activity, identification of learning result, and subsequent treatment after evaluation. 5)Specific activity at the step of selection and development of instructional media consists of reidentification of instructional objectives determination of learning type, drawing up instructional media analysis sheet, synthesis of selected media, and explanatory note of selected media. In order to increase efficiency of instruction at the step of determining instructional strategy, this step should be considered simultaneously. 6)The step of try-out and evaluation of instructional design should be efficient when designed instruction was inputted at class after evaluation of each step of instructional design.

  • PDF

Evaluation of Foot Pressures and Subjective Discomfort Ratings associated with Sneakers, High Heels, and Kill Heels (운동화, 하이힐, 그리고 킬힐에 따른 족압과 주관적 불편도 평가)

  • Song, Jae-Woong;Kim, Sung-Ja;Lee, Ga-Hee;Song, Ki-Burm;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • Ten young females were participated in this study to investigate the effects of types of shoes (sneakers, high heels, kill heels), types of tasks (standing, walking floor, step up and down), and areas of foot (fore foot, middle foot, rear foot) on foot pressures as well as subjective discomfort ratings. Results showed that kill heels had the most discomfort shoes, followed by high heels and sneakers. Generally, as the heel was higher, the discomfort of foot increased. For the analyses of task types, generally discomfort ratings were highest for the step down and up, followed by walking floor and standing. Especially discomfort ratings of high heels and kill heels were more evident in case of step up and step down than standing and walking floor. Standing task was rated as the lowest levels of discomfort on users' foot. Peak and mean foot pressures were also evaluated in this study. The findings represented that there was no significant differences between types of shoes in both peak and mean foot pressures. The peak pressure (82.14kPa) and mean pressure (40.32kPa) for standing task were significantly lower than those of other tasks [walking floor (190.55kPa, 55.46kPa), step up (191.43kPa, 53.80kPa), and step down (200.66kPa, 52.62kPa)]. Generally discomfort ratings and peak/mean pressures associated with foot showed that fore foot had higher discomfort ratings as well as peak and mean pressures than middle and rear foots. In particularly, this trend was more obvious in case of high heels and kill heels. For the high heels and kill heels, the peak pressures of fore foot were 4.5~4.8 times and 2.3~2.5 times greater than that of middle foot and rear foot, respectively, whereas the peak pressures of fore foot were 2.9 times and 1.7 times greater than that of middle and rear foots, respectively, in case of sneakers.

Step-One in Pre-regulator Boost Power-Factor-Correction Converter Design

  • Orabi, Mohamed;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.18-27
    • /
    • 2004
  • The output storage capacitor of the PFC converters is commonly designed for the selected hold-up time or the allowed output ripple voltage percentage. Nevertheless, this output capacitor is a main contribution factor to the PFC system stability. Moreover, seeking for a minimum output storage capacitor that assures the PFC desired operation under all condition, and providing the advantage of a small size and low cost is the main interesting target for engineering. Therefore, in this issue the design steps of the PFC converter have been discussed depending on three choices, output ripple, hold-up time, and stability. It is cleared that any design must take the minimum required storage capacitor for stability prospective as step-l in deign, then apply for any other specification like hold-up time or ripple percentage.

An XML-based Digital Mock-Up System for Heterogeneous Multi-CAD Assembly (XML을 이용한 이기종 CAD 조립체 DMU시스템의 설계)

  • Song, In-Ho;Chung, Sung-Chong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.6 s.261
    • /
    • pp.635-643
    • /
    • 2007
  • As many engineers and technicians are involved in the design process of large scale and/or complex products, there are a lot of miss matches and interferences due to designers' faults and several kinds of CAD systems. Recently, CAD systems are applied to verify and check the assembly process. Digital Mock-Up(DMU) system, a tool to build a virtual mock-up in the design stage, has been used to prevent the interferences and miss matches during precision design processes. Using the virtual assembly tool, engineers are able to design precision and interference free parts without physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product. Several organizations are involved in the distributed design environment for heterogeneous multi-CAD assembly. XML and the lightweight CAD file are proposed for the multi-CAD assembly. XML data contains hierarchy of the heterogenenous multi-CAD assembly. STEP PDM schema and STEP ISO 10303-28 formations are applied to construct the XML data. The lightweight CAD file produced from various CAD files through ACIS kernel and InterOp not only contains mesn, B-Rep and topological data, but also is used to visualize CAD data and to verify dimensions. Developed system is executed on the desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Real-time interference and fitness checks, dimensional verification, and design and assembly verification are performed on the developed system. Assembly of heterogeneous models for a car is conducted to verify the effectiveness of the developed DMU system on the Internet.

Improved Detection of Metastases by Step Sectioning and Immuno-Histochemical Staining of Axillary Sentinel Nodes in Patients with Breast Carcinoma

  • Ensani, Fereshteh;Enayati, Ladan;Rajabiani, Afsaneh;Omranipour, Ramesh;Alavi, Nasrinalsadat;Mosahebi, Sara
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5731-5734
    • /
    • 2013
  • Background: The object of this study was to examine whether a new protocol including step-sectioning and immunohistochemistry (IHC) staining of axillary sentinel nodes (SN) would lead to detection of more metastases in patients with breast cancer. Materials and Methods: Sixty-nine tumor free sentinel lymph nodes were examined. Step frozen sectioning was performed on formalin fixed SN and stained both by hematoxylin and eosin (H and E) and cytokeratin markers using IHC. Any tumoral cell in IHC stained slides were considered as a positive result. Metastases up to 0.2 mm were considered as isolated tumor cells and 0.2 up to 2 mm as micrometastasis. Results: Mean age of the patients was $48.7{\pm}12.2$ years. Step sectioning of the SN revealed 11 involved by metastasis which was statistically significant (p<0.001). Furthermore, 15 (21.7%) of the patients revealed positive results in IHC staining for pan-CK marker and this was also statistically significant (p=0.001). Ten patients had tumoral involvement in lymph nodes harvested from axillary dissection and 4 out of 15 lymph nodes with positive result for CK marker were isolated tumor cells. However, 4 of 10 patients with tumor positive lymph nodes in axillary dissection were negative for CK marker and in contrast 6 of the pan-CK positive SN were in patients with tumor-free axillary lymph nodes. Conclusions: Both IHC and step sectioning improve the detection rate of metastases. Considering the similar power of these two methods, we recommend using either IHC staining or step sectioning for better evaluation of harvested SNs.