• Title/Summary/Keyword: Stent graft

Search Result 98, Processing Time 0.024 seconds

Bypass of Superior Vena Cava with Spiral Vein Graft (Spiral Vein Graft를 이용한 상대정맥 우회로 조성술-치험 1례-)

  • Hwang, Su-Hui;Kim, Byeong-Jun;Jeong, Seong-Un
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.344-347
    • /
    • 1997
  • A 49-year-old female patient who had obstruction of superior vents cave(SVC) with SVC syndrome was successfully managed by bypass operation of superior vents cava with spiral vein graft. A composite spiral vein graft was placed between the right innominate vein and the right atrium to bypass the occluded SVC. The graft was constructed from the patient's own saphenous vein, which was split longitudinally and wrapped around a stent in spiral fashion and the edges of the vein were sutured together to form a large autogenous conduit. The patient was relieved o SVC obstructive symtoms and signs and discharged 21 days postoperatively without any complication.

  • PDF

Retrograde Aortic Dissection after Thoracic Endovascular Aortic Repair for Descending Aorta - 2 case reports- (하행 대동맥 내 스텐트-도관 삽입 후 발생한 역행성 대동맥 박리 - 2예 보고 -)

  • Hong, Soon-Chang;Kim, Jung-Hwan;Lee, Hee-Jeong;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.758-763
    • /
    • 2010
  • In current era, thoracic endovascular aortic repair (TEVAR) has gained popularity. But, it bears the risk of serious complications such as treatment failure from endoleak, retrograde aortic dissection caused by injury of aortic wall at landing zone, or aortic rupture resulting from stent graft infection. We report two cases of surgical repair of retrograde aortic dissection after TAVAR applied to acute Stanford type B aortic dissection or traumatic aortic disruption.

Acute Thrombotic Occlusion of Left Internal Jugular Vein Compressed by Bypass Graft for Thoracic Endovascular Aortic Repair Debranching Procedure

  • Sim, Hyung Tae;Beom, Min Sun;Kim, Sung Ryong;Ryu, Sang Wan
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.552-555
    • /
    • 2014
  • Thoracic endovascular aortic repair has become a widespread alternative treatment option for thoracic aortic aneurysm. The debranching of arch vessels may be required to provide an acceptable landing zone for an endovascular stent graft. We report a case where the bypass graft used in the thoracic endovascular aortic repair procedure compressed the left internal jugular vein, causing acute thrombotic occlusion.

Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location (혈액투석 접근로 기능부전에서의 비피복형 스텐트: 접근로 종류와 스텐트 위치에 따른 개통률 평가)

  • Kyungmin Lee;Je Hwan Won;Yohan Kwon;Su Hyung Lee;Jun Bae Bang;Jinoo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.197-211
    • /
    • 2023
  • Purpose To evaluate the circuit patency after nitinol bare-metal stent (BMS) placement according to the type of access and location of the stent in dysfunctional hemodialysis access. Materials and Methods Between January 2017 and December 2019, 159 patients (mean age, 64.1 ± 13.2 years) underwent nitinol BMS placement for dysfunctional access. The location of stents was as follows: 18 brachiocephalic vein, 51 cephalic arch, 40 upper arm vein, 10 juxta-anastomotic vein, 7 arteriovenous (AV) anastomosis, and 33 graft-vein (GV) anastomosis. Circuit patency was evaluated by the Kaplan-Meier method, and cox regression model. Results A total of 159 stents were successfully deployed in 103 AV fistula (AVF) and 56 AV graft (AVG). AVG showed lower primary and secondary patency at 12-months compared with AVF (primary patency; 25.0% vs. 44.7%; p = 0.005, secondary patency; 76.8% vs. 92.2%; p = 0.014). Cox regression model demonstrated poorer primary patency at 12 months after stenting in the cephalic arch and GV anastomosis compared with the other sites. Conclusion AVF showed better primary and secondary circuit patency at 12 months following the placement of BMS compared with AVG. Stents in the cephalic arch and GV anastomosis were associated with poorer primary patency at 12 months compared to those in other locations.

Hybrid Operation of a Kommerell’s Diverticulum with Left Aberrant Subclavian Artery (비정상 좌측 쇄골하동맥을 동반한 Kommerell 게실의 하이브리드 수술법)

  • Kim, Hye-Won;Lee, Jae-Won;Jung, Sung-Ho;Jung, Jae-Seung;Jung, Jong-Pil
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.458-461
    • /
    • 2010
  • A 53-year-old woman had right aortic arch, Kommerell’s diverticulum and aberrant left subclavian artery (LSA) without any compressive symptoms. Hybrid operation was performed. This consisted of LSA bypass using a 6 mm ringed Gore-Tex graft between the left common carotid artery and aberrant LSA via a left supraclavicular incision, and stent graft insertion into the aortic arch via the right femoral artery. Postoperative computed tomography as well as intraoperative angiography demonstrated successful occlusion of Kommerell’s diverticulum and bypass of the aberrant LSA. There were no complications related to the operation or the intervention.

The Successfully Redoaugmentation of Budd-Chiari Syndrome with Using Gore-Tex Patch of the IVC Obstruction (Budd-Chiari Syndrome 하공정맥 폐색의 Gore Tex Patch로의 성공적인 재확장술)

  • 지행옥;이재훈;전순호;정태열;신성호;전양빈;손상태
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.75-79
    • /
    • 1999
  • Budd-Chiari syndrome is a state of hepatic failure caused by impairment of blood flow anywhere from the inferior vena cava to the right atrium. In this case, a 45 year old patient had undergone membranotomy and dilatation with autogenous pericardial graft due to obstruction of the inferior vena cava caused by a congenital membrane in 1987. Ten years after the operation, restenosis occurred. Although a noninvasive method with a Gianturco stent dilatation was performed, a satisfactory result was not obtained. A reoperation was performed. The stenotic segment of inferior vena cava was excised and after augmentation with a prepared pentagon shaped Gore-Tex artificial graft allowing passage of two fingers. The patient's postoperative course was uneventful without signs of rebleeding or any other complications and the patient was discharged at postoperative two weeks without the use of anticoagulants. An excellent result was obtainable after operation using a prepared Gore-Tex graft and such a result. Reoperational case of Budd-Chiari syndrome may require rapid and excellent the operative techenic by prevention of massive bleeding under use of extracorporeal circulation.

  • PDF

Thoracic Endovascular Repair for Complicated Type B Acute Aortic Dissection with Distal Malperfusion

  • Choo, Suk-Jung;Jung, Sung-Ho;Kim, Ji-Eon;Lim, Ju-Yong;Ju, Min-Ho
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.427-431
    • /
    • 2011
  • Successful thoracic endovascular repair for complicated Stanford type B acute aortic dissection in two patients is herein reported. The true lumen flow was immediately restored following stent graft deployment in the descending thoracic aorta with subsequent resolution of the distal malperfusion syndrome. One patient is doing well more than 15 months after surgery and another patient who was treated more recently is also doing well 7 months postoperatively.

Successful Repair of Type I Endoleak Using the Frozen Elephant Trunk Technique

  • Kim, Seon Hee;Song, Seunghwan;Kim, Sang-pil;Lee, Chung Won;Son, Joohyung
    • Journal of Chest Surgery
    • /
    • v.49 no.4
    • /
    • pp.298-301
    • /
    • 2016
  • Thoracic endovascular aortic repair (TEVAR) has emerged as an effective therapy for a variety of thoracic aortic pathologies. However, various types of endoleak remain a major concern, and its treatment is often challenging. We report a case of type I endoleak occurring 19 months after zone II hybrid TEVAR. The endoleak was successfully repaired by the frozen elephant trunk technique, without removal of a previous stent graft, combined with ascending aorta and total arch replacement.

Total Arch Replacement with Stented Elephant Trunk in DeBakey Type I Acute Aortic Dissection

  • Choi, Hyung-Yoon;Song, Suk-Won;Hong, Sun-Chang;Lim, Sun-Hee
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.68-71
    • /
    • 2013
  • A 67-year-old female patient was treated with conventional total arch replacement and insertion of a stented elephant trunk (SET) graft into the descending thoracic aorta for acute DeBakey type I aortic dissection at one time. She had been treated with right coronary artery stent insertion for acute myocardial infarct 4 days earlier, and at that time, she was diagnosed with acute DeBakey type I aortic dissection from the ascending aorta to the suprarenal artery based on trans-esophageal echocardiography and aorta computed tomography. Through a median sternotomy, we inserted the SET graft through the opened aorta to the descending aorta. We also performed anastomosis between the proximal stented graft and the distal aortic arch, and then performed total arch replacement. For acute DeBakey type I aortic dissection, we report total arch replacement with insertion of a SET graft as a combination of conventional surgery and the interventional technique.

Percutaneous Endovascular Stent-graft Treatment for Aortic Disease in High Risk Patients: The Early and Mid-term Results (고위험군의 대동맥류 환자에서 경피적으로 삽입이 가능한 스텐트 그라프트를 이용한 치료: 조기 및 중기성적)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Kang, Sung-Gwon;Yoon, Chang-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.239-246
    • /
    • 2008
  • Background: Aortic surgery for high risk patients has high mortality and morbidity rates, and the necessity of performing aortic surgery in cancer patients is questionable because of their short life expectancy. Endovascular repair of aneurysm repair can be considered for high risk patients and cancer patients because it has relatively lower invasiveness and shorter recovery times than aortic surgery does. Especially, percutaneous endovascular stent graft treatment is more useful for high risk patients because it does not require general anesthesia. Material and Method: From July 2003 to September 2007, twelve patients who had inoperable malignancy or who had a high risk of complication because of their combined diseases during aortic surgery underwent endovascular aortic aneurysm repair. he indications for endovascular repair were abdominal aortic aneurysm in 5 patients, descending thoracic aortic aneurysm in 6 patients and acute type B aortic dissection in one patient. The underlying combined disease of these patients were malignancy in 3 patients, respiratory disease in 6 patients, old age with neurologic disease in 6 patients, Behcet's iseae in one patient and chronic renal failure in one patient. Result: Stent grafts were inserted percutaneously in all cases. There were 4 hospital deaths and there were 3 delayed deaths during the follow-up periods. There were no deaths from aortic disease, except one hospital death. There were several complications: a mild cerebrovascular accident occurred in one patient, acute renal failure occurred in 2 patients and ischemic bowel necrosis occurred in one patient. Mild type I endoleak was observed in 2 patients and type II endoleak was observed in a patient after stent graft implantation. Newly developed type I endoleak was observed in a patient during the follow-up period. Conclusion: Percutaneous endovascular stent graft insertion is relatively safe procedure for high risk patients and cancer patients. Yet it seems that its indications and its long term results need to be further researched.