• Title/Summary/Keyword: Stenosis Model

Search Result 86, Processing Time 0.024 seconds

Hemodynamics of a Connecting conduit Between the Left Ventricle and the Left Decending Coronary Artery

  • Shim, Eun-Bo;Sah, Jong-Yub
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.2
    • /
    • pp.20-29
    • /
    • 2003
  • A new treatment for coronary artery occlusive disease is being developed in which a shunt or conduit is placed directly connecting the left ventricle with the diseased artery at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Simulation results indicate that in complete LAD occlusion, flow can be returned to approximately 65% of normal if the conduit resistance is equal for forward and reverse flow, increasing to 80% in the limit in which backflow resistance is infinite. Increases in flow rate produced by asymmetric flow resistance are considerably enhanced in the case of a partial LAD obstruction since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle("steal") during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but leads to considerable augmentation when the resistance is asymmetric. These results suggest that an LV-LAD conduit will be beneficial when stenosis resistance(Rst) > 27 PRU if resistance is symmetric.

  • PDF

Pathogenetic Overlapping of Renovascular Hypertension Developed in a Child with Takayasu Arteritis: 'One-clip, One and Half-kidney Model'

  • Lee, Su Jeong;Baek, Hee Sun;Jang, Hea Min;Kim, Hyung-Kee;Huh, Seung;Cho, Min Hyun
    • Childhood Kidney Diseases
    • /
    • v.20 no.1
    • /
    • pp.33-36
    • /
    • 2016
  • There are two pathogenic models of renovascular hypertension (RVH) originating from renal artery stenosis. We noted a case of a boy who had severe hypertension with atrophic left kidney, hypertrophic right kidney, a segmental stricture of the abdominal aorta, and total occlusion of the right renal artery. Due to the atrophic change of the contralateral, unclipped left kidney, this patient presented with various clinical manifestations related to both models of pathogenesis of RVH occurring at the same time. We conclude that this patient presented with the middle stage of the two RVH pathogenetic models, so called the 'one-clip, one and half-kidney model.'

Biomechanical Evaluation of SMA Dynamic Stabilization for Spinal fusion (척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가)

  • Kim Y.H.;Park W.M.;Kim K.;Park H.K.;Joo J.W.;Park K.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.517-518
    • /
    • 2006
  • In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.

  • PDF

Efficacy and Safety of a Newly Developed Self-Expanding Open-Cell Type Nitinol Stent for Peripheral Arteries: A Preclinical Study in Minipigs (새로 개발된 말초동맥용 자가팽창성 개방형 니티놀 스텐트의 유효성 및 안전성 평가: 미니피그 전임상실험)

  • Min Uk Kim;Jae Hwan Lee;Chang Jin Yoon;Won Seok Choi;Saebeom Hur;Jin Wook Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.899-911
    • /
    • 2020
  • Purpose To evaluate the safety and efficacy of the newly designed open-cell type self-expandable nitinol stent (NiTi-stent) for peripheral arteries. Materials and Methods Twenty-eight limbs of 14 minipigs were randomly assigned to the NiTistent group or conventional nitinol stent group. Stents were symmetrically implanted into the iliac arteries of each animal using carotid artery approach and were observed for 1 month (n = 5) and 6 months (n = 9). The angiographic lumen diameter (ALD), late lumen loss, angiographic stenosis, histomorphometric lumen area, neointimal area, and area stenosis were analyzed and compared between the groups. Results Stent migration, stent fracture, or thrombus formation were not observed in either group. At the 1-month follow-up, the neointimal area (p = 0.008) and area stenosis (p = 0.016) were significantly smaller in the NiTi-stent group than in the control group. At the 6-months followup, the NiTi-stent group showed significantly larger ALD (p = 0.014), less late lumen loss (p = 0.019), less angiographic stenosis (p = 0.014), larger lumen area (p = 0.040), and smaller neointimal area and area stenosis (p = 0.004 and p = 0.014, respectively) compared with the control group. Conclusion The NiTi-stent is as safe and effective as the conventional nitinol stent and induces less neointimal hyperplasia in a minipig iliac artery model.

Detecting Regions of Stenosis and Aneurysm in a 3D Blood Vessel Model (3차원 혈관 모델에서 협착 및 팽창 영역 탐색 방안)

  • Park, Sang-Jin;Kim, Jae-Sung;Park, Hyungjun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.113-120
    • /
    • 2018
  • Angiography and CT angiography are used widely for the examination of vascular diseases, but the diagnosis of such diseases is made mostly by the subjective judgment of the inspector. This paper proposes a method for detecting the suspicious regions of stenosis and aneurysm in the inner surfaces of 3D blood vessel models reconstructed from medical images. Initially, the 3D curve-skeletons of the blood vessel models and the contours at the nodes of the curve-skeletons were generated. Next, the 3D curve-skeletons were divided into a set of branches and the areas of normal contours of nodes located in each branch were calculated. The nodes whose contours contain suspicious regions were detected by taking into account the average area, maximum and minimum areas, and the area difference between the adjacent normal contours. The diagnosis of stenosis and aneurysm can be supported by properly visualizing the suspicious regions detected. The suspicious regions of the disease were identified by implementing and testing it using several data sets of human blood vessels, highlighting the usefulness of the proposed method.

Survival Rates and Risk Factors for Cephalad and L5-S1 Adjacent Segment Degeneration after L5 Floating Lumbar Fusion : A Minimum 2-Year Follow-Up

  • Lee, Young-Seok;Kim, Young-Baeg;Park, Seung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.108-113
    • /
    • 2015
  • Objective : Although the L5-S1 has distinct structural features in comparison with other lumbar spine segments, not much is known about adjacent segment degeneration (ASD) at the L5-S1 segment. The aim of study was to compare the incidence and character of ASD of the cephalad and L5-S1 segments after L5 floating lumbar fusion. Methods : From 2005 to 2010, 115 patients who underwent L5 floating lumber fusion were investigated. The mean follow-up period was 46.1 months. The incidence of radiological and clinical ASD of the cephalad and the L5-S1 segments was compared using survival analysis. Risk factors affecting ASD were analyzed using a log rank test and the Cox proportional hazard model. Results : Radiological ASD of the L5-S1 segment had a statistically significant higher survival rate than that of the cephalad segment (p=0.001). However, clinical ASD of the L5-S1 segment was significantly lower survival rates than that of the cephalad segment (p=0.038). Risk factor analysis showed that disc degeneration of the cephalad segment and preoperative spinal stenosis of the L5-S1 segment were risk factors. Conclusion : In L5 floating fusion, radiological ASD was more common in the cephalad segment and clinical ASD was more common in the L5-S1 segment. At the L5-S1 segment, the degree of spinal stenosis appears to be the most influential risk factor in ASD incidences, unlike the cephalad segment.

Reduced Burst Release from ePTFE Grafts: A New Coating Method for Controlled Drug Release

  • Nam, Hye-Yeong;Kim, Dae-Joong;Lim, Hyun-Jung;Lee, Byung-Ha;Baek, In-Su;Park, Sang-Hun;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.422-426
    • /
    • 2008
  • Hemodialysis graft coated with paclitaxel prevents stenosis; however, large initial burst release of paclitaxel causes many negative effects such as drug toxicity and inefficient drug loss. Therefore we developed and tested a novel coating method, double dipping, to provide controlled and sustained release of paclitaxel locally. Expanded polytetrafluoroethylene (ePTFE) grafts were dipped twice into a solution of several different paclitaxel concentrations. In vitro release tests of the double dipping method showed that early burst release could be somewhat retarded and followed by sustained release for a long time. We observed the effect of paclitaxel coating by double dipping in porcine model of arterio-venous (AV) grafts between the common carotid artery and the external jugular vein. 12 weeks after constructing AV grafts, cross sections of the graft venous anastomosis were obtained and analyzed. Paclitaxel coated ePTFE grafts by double dipping were observed to prevent neointimal hyperplasia and therefore reduced stenosis of the arteriovenous hemodialysis grafts, especially at the graft venous anastomosis sites. Our results demonstrate that second dipping of ePTFE graft, which was already coated once with paclitaxel, washes off the drug on a surface of the graft and affects the ratio of paclitaxel on the surface to that of the inner space, possibly by diffusion: thus the early burst of drug can be somewhat reduced.

Development and Evaluation of RANS based Turbulence Model for Viscoelastic Fluid (점탄성 유체해석용 RANS 기반 난류 모델 개발 및 검증)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.545-550
    • /
    • 2017
  • When the systolic blood pressure is high, intermittent turbulence in blood flow appears in the aorta and carotid artery with stenosis during the systolic period. The turbulent blood flow is difficult to analyze using the Newtonian turbulence model due to the viscous characteristics of blood flow. As the shear rate is increased, the blood viscosity decreases by the viscoelastic properties of blood and a drag reduction phenomenon occurs in turbulent blood flow. Therefore, a new non-Newtonian turbulent model is required for viscoelastic fluid and hemodynamics. The main aims of this study were to develop a non-Newtonian turbulence model using the drag reduction phenomenon based on the standard $k-{\varepsilon}$ turbulent model for a general non-Newtonian fluid. This was validated with the experimental data and has a good tendency for non-Newtonian turbulent flow. In addition, the computation time and resources were lower than those of the low Reynolds number turbulent model. A modified turbulent model was used to analyze various turbulent blood flows.

Fluid-structure interactions of physiological flow in stenosed artery

  • Buriev, Bahtiyor;Kim, Tae-Dong;Seo, Tae-Won
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.1
    • /
    • pp.39-46
    • /
    • 2009
  • Atherosclerosis is a disease that narrows, thickens, hardens, and restructures a blood vessel due to substantial plaque deposit. The geometric models of the considered stenotic blood flow are three different types of constriction of cross-sectional area of blood vessel; 25%, 50%, and 75% of constriction. The computational model with the fluid-structure interaction is introduced to investigate the wall shear stresses, blood flow field and recirculation zone in the stenotic vessels. The velocity profile in a compliant stenotic artery with various constrictions is subjected to prescribed physiologic waveform. The computational simulations were performed, in which the physiological flow through a compliant axisymmetric stenotic blood vessel was solved using commercial software ADINA 8.4 developed by finite element method. We demonstrated comparisons of the wall shear stress with or without the fluid-structure interaction and their velocity profiles under the physiological flow condition in the compliant stenotic artery. The present results enhance our understanding of the hemodynamic characteristics in a compliant stenotic artery.

Velocity and Shear Stress Distributions for Steady and Physiological Flows in the Abdominal Aorta/lLIAC Artery Bifurcation (복부대동맥/장골동맥 분기혈관내 정상 및 박동성 유동의 속도와 전단응력분포)

  • 서상호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 1997
  • Steady and physiological flows of a Newtonian fluid and blood in the abdominal gorta/iliac artery bifurcation are numerically simulated to understand the etiology and pathogenesis of atherosclerosis. Distributions of velocity, pressure, and wall shear stress in the bifurcated arterial vessel model are calculated to investigate the differences of flow characteristics between steady and physiological flows and to compare flow characteristics of blood with that of a Newtonian fluid For the given Reynolds number the flow characteristics of physiological flows for a Newtonian fluid and blood in the bifurcated arterial vessel are quite different from thcse of steady flows. No flow separation or flow reversal in the bifurcated region appears downstream of a stenosis during the acceleration phase. However, during the deceleration phase the flow exhibits flow separation in the outer walls of daugtlter branches, which extends to the entire wall region.

  • PDF