• 제목/요약/키워드: Steel reinforcement concrete

검색결과 1,246건 처리시간 0.019초

Improved analytical method for adhesive stresses in plated beam: Effect of shear deformation

  • Guenaneche, B.;Benyoucef, S.;Tounsi, A.;Adda Bedia, E.A.
    • Advances in concrete construction
    • /
    • 제7권3호
    • /
    • pp.151-166
    • /
    • 2019
  • This paper introduces a new efficient analytical method, based on shear deformations obtained with 2D elasticity theory approach, to perform an explicit closed-form solution for calculation the interfacial shear and normal stresses in plated RC beam. The materials of plate, necessary for the reinforcement of the beam, are in general made with fiber reinforced polymers (Carbon or Glass) or steel. The experimental tests showed that at the ends of the plate, high shear and normal stresses are developed, consequently a debonding phenomenon at this position produce a sudden failure of the soffit plate. The interfacial stresses play a significant role in understanding this premature debonding failure of such repaired structures. In order to efficiently model the calculation of the interfacial stresses we have integrated the effect of shear deformations using the equilibrium equations of the elasticity. The approach of this method includes stress-strain and strain-displacement relationships for the adhesive and adherends. The use of the stresses continuity conditions at interfaces between the adhesive and adherents, results pair of second-order and fourth-order coupled ordinary differential equations. The analytical solution for this coupled differential equations give new explicit closed-form solution including shear deformations effects. This new solution is indented for applications of all plated beam. Finally, numerical results obtained with this method are in agreement of the existing solutions and the experimental results.

The effect of three-variable viscoelastic foundation on the wave propagation in functionally graded sandwich plates via a simple quasi-3D HSDT

  • Tahir, Saeed I.;Tounsi, Abdelouahed;Chikh, Abdelbaki;Al-Osta, Mohammed A.;Al-Dulaijan, Salah U.;Al-Zahrani, Mesfer M.
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.501-511
    • /
    • 2022
  • Earthquake Resistant Design Philosophy seeks (a) no damage, (b) no significant structural damage, and (c) significant structural damage but no collapse of normal buildings, under minor, moderate and severe levels of earthquake shaking, respectively. A procedure is proposed for seismic design of low-rise reinforced concrete special moment frame buildings, which is consistent with this philosophy; buildings are designed to be ductile through appropriate sizing and reinforcement detailing, such that they resist severe level of earthquake shaking without collapse. Nonlinear analyses of study buildings are used to determine quantitatively (a) ranges of design parameters required to assure the required deformability in normal buildings to resist the severe level of earthquake shaking, (b) four specific limit states that represent the start of different structural damage states, and (c) levels of minor and moderate earthquake shakings stated in the philosophy along with an extreme level of earthquake shaking associated with the structural damage state of no collapse. The four limits of structural damage states and the three levels of earthquake shaking identified are shown to be consistent with the performance-based design guidelines available in literature. Finally, nonlinear analyses results are used to confirm the efficacy of the proposed procedure.

중성화와 염해의 복합 열화 환경하의 콘크리트 내에서의 Cr강방식철근의 방식성 (Corrosion Resistance of Cr-bearing Rebar in Concrete Subjected to Carbonation and Chloride Attack)

  • 태성호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.115-122
    • /
    • 2006
  • 중성화와 염해의 복합 열화 환경하의 콘크리트 내에서의 Cr강방식철근의 방식성을 평가하기 위하여 Cr함유율이 다른 10종류의 철근을 피복 두께 20mm 위치에 매입한 염화물 이온 함유량 0.3, 0.6, 1.2, $2.4kg/{m^3}$의 콘크리트 공시체를 제작하였다. 그 후 촉진 중성화 시험 및 고저온 건습 반복의 부식 촉진 시험 기간 중의 Cr강방식철근의 자연전위, 부식면적률, 부식감량률의 경시변화를 측정함으로써 각 부식 환경에 대한 Cr강방식철근의 방식성에 대하여 검토하였다. 그 결과, 중성화와 염해의 복합 열화 환경의 경우, 염화물 이온 함유량 $1.2kg/m^3$$2.4kg/m^3$에 대하여 각각 Cr함유율 7% 이상과 9% 이상의 Cr강방식철근에서 방식성이 확인되었다.

슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향 (Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection)

  • 최명신;조인중;안종문;신성우
    • 콘크리트학회논문집
    • /
    • 제19권4호
    • /
    • pp.515-525
    • /
    • 2007
  • 본 연구는 주거용 고층 건물에서 폭넓게 사용되고 있는 플랫플레이트 구조에서 장방형 기둥-슬래브 접합부를 대상으로 실시한 4개의 실험 결과를 분석한 것이다. 이 연구의 목적은 지진하중과 같이 반복적으로 작용하는 횡하중에 대하여 기둥 단면의 형상비 (${\beta}_c=c_1/c_2$=횡하중과 나란한 방향의 기둥 단면의 크기/횡하중과 직교 방향의 기둥 단면의 크기)에 따른 접합부의 이력 거동을 비교 평가한 것이다. 기둥 단면의 형상비는 $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$으로 선정되었고, 기둥 또는 슬래브 위험단면의 둘레 길이 $(b_o)$가 일정하지 않을 경우 공칭 수직 전단력 $(V_c)$의 크기기 변화하여 중력 전단력비의 차이가 발생하기 때문에 기둥 양변의 크기를 동시에 변화시켜서 $b_o$가 일정해 지도록 기둥 단면의 크기를 결정하였다. 그리고 슬래브 휨 철근비와 중력 전단력비 $(V_g/V_c)$ 등 접합부의 이력 거동에 영향을 줄 수 있는 다른 영향 인자들은 일정한 조건으로 계획하여 기둥 형상비의 영향을 고찰할 수 있도록 하였다. 일정 수직하중과 반복횡하중이 작용하는 슬래브_기둥 접합부의 실험을 통해서 뚫림전단파괴 양상과 균열 패턴, 철근 및 콘크리트의 변형률, 접합부의 강도와 강성, 그리고 변형 능력 등을 기둥 형상비 변수에 따라 분석하였다. 또한, ACI 318-05 설계기준의 편심 전단응력 모델에 의한 전단응력을 실험 결과와 비교하여 평가하였고, 실험 결과에 기초하여 휨과 전단에 의한 접합부 불균형모멘트 전달비율에 대한 검토를 하였다.

淸州 및 報恩地方의 頭首工洪水災害에 關한 調査硏究(II) -災害原因 및 對策方案을 中心으로- (A Study on the Damages of Head Works by the Storm Flood in the Area of Cheong Ju and Boeun -Emphasis onFactors Influenced on the Disasters and their Countermeasures-)

  • 남성우;김철기
    • 한국농공학회지
    • /
    • 제24권2호
    • /
    • pp.49-55
    • /
    • 1982
  • The purpose of this study is to classify the factors influenced on the damages of head works suffered from the storm flood occurred on July 22 1980 in both Musim and Bochong rivers and to find out an integral counter measures against the causes influenced on the disaster of head works in the engineering aspect of planning, design, construction and maintenance. In this survey, number of samples was taken 25 head Works, and the counter measures against the causes of their disasters summarized was as follows, 1. In the aspect of planning a. As the flood water level after the establishment of head works is more increased than the level before setting of head works owing to having more gentle slope of river bed between the head works than nature slope of river bed. Number of head works should be reduced for the appropriate annexation of them b. In the place where head works is established on the curved point of levee, the destruction of levee becomes severe by the strong deflective current. Therefore the setting of head works on the curved point should be kept off as long as possible and in case of unavoidable circumstances the construction method such as reinforced concrete wall or stone wall filed with concrete and anchored bank revetments should be considered. 2. In the aspect of design a. As scoring phenomena at up stream is serious around the weir Where the concentration of strong current is present in such a place, up stream apron having impermeability should be designed to resist and prevent scoring. b. As the length of apron and protected bed is too short to prevent scoring as down stream bed, the design length should be taken somewhat more than the calculated value, but in the case the calculated length becomes too long to be profitable, a device of water cushion should be considered. c. The structure of protected river bed should be improved to make stone mesh bags fixed to apron and to have vinyl mattress laid on river bed together with the improvement for increasing the stability of stone mesh bags and preventing the sucked sand from the river bed. d. As the shortage of cut-off length, especialy in case of the cutoffs conneting both shore sides of river makes the cause of destruction of embankment and weir body, the culculation of cut-off length should be taken enough length based on seepage length. 3. In the aspect of design and constructions a. The overturing destruction of weir by piping action was based on the jet water through cracks at the construction and expansion joints. therefore the expansion joint should be designed and constructed with the insertion of water proof plate and asphalt filling, and the construction joint, with concaved shape structure and steel reinforcement. b. As the wrong design and construction of the weep holes on apron will cause water piping and weir destruction, the design and construction of filter based on the rule of filter should be kept for weep holes. c. The wrong design and construction of bank revetment caused the severe destruction of levee and weir body resulting from scoring and impulse by strong current and formation of water route behind the revetment. Therefore bank revetment should be designod and constructed with stone wall filled with concrete and anchored, or reinforced concrete wall to prevent the formation of water flow route behind the wall and to resist against the scoring and impulse of strong stream. 4. In the aspect of maintenance When the damaged parts occurred at head works the authorities and farmers concerned should find and mend them as soon as possible with mutual cooperation, and on the other hand public citizen should be guided for good use of public property.

  • PDF

고강도 확대머리 인장철근을 가지는 SFRC 깊은 보의 전단강도 (Shear Strength of SFRC Deep Beam with High Strength Headed Reinforcing Tensile Bars)

  • 김영록;이창용;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.111-117
    • /
    • 2019
  • 확대머리 SD600 고강도 인장철근으로 단부 정착된 SFRC 깊은보의 전단성능을 평가하기 위해 전단 실험을 수행하였다. 실험 변수는 주인장 철근의 단부 정착방법(확대머리 철근, 일자형 철근), 단부 정착길이, 전단보강근 유무 등이다. 전단경간비는 1을 가지는 실험체에 대한 전단실험결과, 모든 실험체는 초기 휨 균열이 발생한 후 경사균열이 진행되면서 최종적으로 압축전단파괴되었다. 확대머리 철근으로 기계적 정착된 실험체들이 일자형 철근 정착에 비하여 5.6~22.4% 더 큰 전단강도를 나타내었다. 확대머리 철근으로 기계적 정착된 실험체들에 대하여 최대하중의 75%까지는 지압응력이 전체 정착응력의 0.9~17.2%에 도달하였으나, 최대하중 시점에서 지압응력이 전체 정착응력의 22.4%~46%에 도달하여 큰 응력 부담률을 나타내었다. 이를 통하여 확대머리 지압응력에 의한 정착응력 증가가 전단강도에 큰 영향을 미침을 알 수 있다. 실험 전단강도가 실용식에 의한 전단강도의 2.68~4.65 배로 평가되어, 실용식이 전단내력을 안전측으로 평가하였다.