• 제목/요약/키워드: Steel cable

검색결과 305건 처리시간 0.025초

Static behaviour of lying multi-stud connectors in cable-pylon anchorage zone

  • Lin, Zhaofei;Liu, Yuqing;He, Jun
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1369-1389
    • /
    • 2015
  • In order to investigate the behaviour of lying multi-stud connectors in cable-pylon anchorage zone, twenty-four push-out tests are carried out with different stud numbers and diameters. The effect of concrete block width and tensile force on shear strength is investigated using the developed and verified finite element model. The results show that the shear strength of the lying multi-stud connectors is reduced in comparison with the lying single-stud connector. The reduction increases with the increasing of the number of studs in the vertical direction. The influence of the stud number on the strength reduction of the lying multi-stud connectors is decreased under combined shear and tension loads compared with under pure shear. Yet, due to multi-stud effect, they still can't be ignored. The concrete block width has a non-negligible effect on the shear strength of the lying multi-stud connectors and therefore should be chosen properly when designing push-out specimens. No obvious difference is observed between the strength reductions of the studs with 22 mm and 25 mm diameters. The shear strengths obtained from the tests are compared with those predicted by AASHTO LRFD and Eurocode 4. Eurocode 4 generally gives conservative predictions of the shear strength, while AASHTO LRFD overestimates the shear strength. In addition, the lying multi-stud connectors with the diameters of 22 m and 25 mm both exhibit adequate ductility according to Eurocode 4. An expression of load-slip curve is proposed for the lying multi-stud connectors and shows good agreement with the test results.

Cable-pulley brace to improve story drift distribution of MRFs with large openings

  • Zahrai, Seyed Mehdi;Mousavi, Seyed Amin
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.863-882
    • /
    • 2016
  • This study aims to introduce a new bracing system by which even super-wide frames with large openings can be braced. The proposed system, hereafter called Cable-Pulley Brace (CPB), is a tension-only bracing system with a rectilinear configuration. In CPB, a wire rope passes through a rectilinear path around the opening(s) and connects the lower corner of the frame to its opposite upper one. CPB is a secondary load resisting system with a nonlinear-elastic hysteretic behavior due to its initial pre-tension load. As a result, the required energy dissipation would be provided by the MRF itself, and the main intention of using CPB is to contribute to the initial and post-yield stiffness of the whole system. Using a stiffness calibration technique, optimum placement of the CPBs is discussed to yield a uniform displacement demand along the height of the structure. A displacement-based design procedure is proposed by which the MRF with CPB can be designed to achieve a uniform distribution of inter-story drifts with predefined values. Obtained results indicated that CPB leads to significant reductions in maximum and residual deformations of the MRF at the expense of minor increase in the maximum base shear and developed axial force demands in the columns. In the case of a typical 5-story residential building, compared to SMRF system, CPB system reduces maximum amounts of inter-story and residual drifts by 35% and 70%, respectively. Moreover, openings of the frame are not interrupted by the CPB. This is the most appealing feature of the proposed bracing system from architectural point of view.

KSTAR PF Coil용 CICC 제작 (Fabrication of KSTAR PF CICC)

  • 임병수;이상일;최정열;정우호;박현기;추용;박갑래;백설희;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.301-303
    • /
    • 2003
  • The KSTAR(Korea Superconducting Tokamak Advanced Research) superconducting magnet system consist of 16 TF(Toroidal Field) and 14 PF(Poloidal Field) coils. Internally-cooled cabled superconductors will be used for the magnet system. The magnet system adopt a superconducting CICC (Cable-In-Conduit Conductor) type. The KSTAR PF 6, 7 CICCs use NbTi Superconducting cable with stainless steel 316LN conduit while the other PF CICC use Incoloy 908 conduit. For the fabrication of PF CICC, superconducting cables have been fabricated and the cable has the diameter of 22.3mm. A continuous CICC jacketing system is developed for the CICC jacketing and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The cabling and the jacketing process is described. The welding condition and design specification of CICCs are also discussed. The fabrication results including the geometrical specification and the void fraction will be discussed.

  • PDF

계장화 압입시험 및 유한요소해석을 이용한 아연도금강판의 기계적 물성 추정 (Determination of Mechanical Properties of Galvanized Steel Sheets Using Instrumented Indentation Technique and Finite Element Analysis)

  • 진지원;곽성종;김태성;노기한;강기원
    • 대한기계학회논문집A
    • /
    • 제36권5호
    • /
    • pp.529-535
    • /
    • 2012
  • 본 논문의 목적은 계장화 압입시험과 유한요소해석을 이용하여 아연도금강판의 기계적 물성을 추정하는 것이다. 먼저 인장시험을 통하여 유한요소해석에 요구되는 두께에 따른 아연도금강판의 기계적 물성을 획득하였으며, 이를 이용하여 유한요소해석을 수행하여 특정지점에서의 소성 응력 및 변형률을 획득하였다. 이러한 유한요소해석의 유효성은 계장화 압입시험의 하중-변위선도와 비교를 통하여 검토하였다. 유한요소해석을 통하여 구한 진응력-진변형률 곡선을 인장시험 결과와 비교하여 이의 정확성을 검증하였으며 또한 이를 바탕으로 대표 응력 및 변형률 산출지점을 재평가하였다.

긴장재의 응력 및 온도변화에 따른 자속투과율 (Permeability of Magnetic Flux of PS Steel for Variation of Stress and Temperature)

  • 박진수;김병화
    • 대한토목학회논문집
    • /
    • 제42권3호
    • /
    • pp.323-331
    • /
    • 2022
  • PS 긴장재의 긴장률, 온도 그리고 자속투과율의 상호관계가 실험적으로 조사되었다. 자속투과율은 두 지점 사이의 자속이 통과하는 비율이다. 실험에 사용된 긴장재는 케이블 교량에 주로 사용되는 ϕ7 mm 고강도 강선과 PSC 긴장재로 사용되는 ϕ12.7 mm 강연선이다. 다양한 도입 긴장률과 온도 조건하에서 강선과 강연선의 자속투과율 실험이 수행되었다. 실험결과로부터, PS 긴장재의 자속투과율은 도입 긴장률에 선형 비례하고, 온도에 선형 반비례함을 알 수 있다. PS 긴장재의 자속투과율-온도-긴장률 사의의 실험적 관계를 미리 알게 되면, 현장에서 PS 강재의 자속투과율과 온도만을 계측함으로써, PS 긴장재의 현재 긴장응력 수준을 변형률 계측 없이 직접 평가할 수 있다.

지진을 받는 현수교의 수직진동 (Vertical Seismic Vibration of Suspension Bridges)

  • 최지훈;이존자;김수보;이용재
    • 한국강구조학회 논문집
    • /
    • 제12권5호통권48호
    • /
    • pp.581-593
    • /
    • 2000
  • 본 연구는 지진하중을 받는 현수교의 수직 동적 해석방법을 발전시켰다. 시간 영역해석, 불규칙 진동 해석 및 스펙트럼 해석의 이론을 체계적으로 정립하였다. 불규칙 진동 해석을 다시 수치적분을 이용하는 방법과 수학적 적분식 및 상관계수를 이용한 방법으로 나누고 각각은 다시 지진하중을 white noise로 가정한 경우와 filtered white noise로 가정한 경우에 대해 CQC 방법과 SRSS 방법을 사용하였다. 현수교의 모델링은 빔, 트러스 및 프레임요소를 사용하였고 케이블과 주탑은 사하중에 의한 기하학적 강성을 고려하였다.

  • PDF

화재에 의한 사장교 케이블의 유한요소 해석 (FEM Analysis on the Damage for the Cable of Cabled-suspension Bridges by Fire)

  • 송용선;이병식;김형주;박원태
    • 한국산학기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.136-142
    • /
    • 2008
  • 최근 케이블을 이용한 현수교 또는 사장교 형식의 교량들이 건설되고 있다. 이러한 교량에서 자동차 충돌등의 사고에 의한 교량위 화재로 손상을 받는 경우가 종종 발생되고 있으나, 화재에 의한 교량구조물의 안정성에 대한 연구는 거의 없는 실정이다. 따라서 본 논문에서는 국도확장사업구간에 시공되고 있는 사장교 교량을 대상으로 하여, 상용소프트웨어인 Solid Works 2007을 사용하여 모델링하고, COSMOS FloWorks 2007소프트웨어에 의한 열전달 해석 및 열응력 해석을 통하여 와이어, 교량위 화재 발생시 와이어, 사재방재 파이프 및 그 주변에 대한 사재방재케이블의 안전을 검토 하였다. 해석변수로는 열원의 온도, 방호책과 열원사이의 거리, 풍속, 스텐인레스강관 끝단의 높이를 사용하였다.

고정하중을 받는 현수교 시스템의 초기형상 결정법 (Initial Shape Analysis of Suspension Bridge System under Dead Load)

  • 김민;김문영
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.511-521
    • /
    • 2010
  • 현수교에서 행어와 만나는 보강거더 정착부의 제로변위(zero displacement)법과 주탑의 케이블 정착부 및 주 케이블과 행어가 만나는 절점에서 힘의 평형조건을 이용하여 현수교 주 케이블의 수평장력 초기평형상태를 결정하기 위한 해석법을 제시한다. 이 방법은, 기존 연구자들의 복잡한 비선형 해석을 통한 현수교 케이블의 해석에 비해 적은 노력으로 주 케이블의 정확한 수평장력 및 초기형상을 결정할 수 있는 효과적인 방법이다. 2차원 및 3차원 현수교 수치해석 예제들로부터 앞선 연구자들의 해석결과와 비교, 검토를 통하여 본 연구의 정확성과 타당성을 입증한다.

현수교의 정착 형식에 따른 이동하중에 의한 동적 응답의 비교 (Comparison of Dynamic Responses According to Anchorage Type of Suspesion Bridges)

  • 서정인;김호경
    • 한국강구조학회 논문집
    • /
    • 제12권1호통권44호
    • /
    • pp.103-110
    • /
    • 2000
  • 현수교는 정착 형식에 따라 타정식과 자정식으로 나누는데, 본 연구는 이 두 가지의 정착 형식의 이동하중에 대한 동적 효과의 차이를 살펴보기 위한 것으로, 연구 결과를 동적확대계수를 차량의 속도와 중량의 효과에 대해 제시함으로써 살펴보았다. 본 연구에 유한요소법을 이용하였다. 비선형 다엽식 현가장치와 트랙터-트레일러의 타이어를 모델링하기 위해 6자유도 시스템으로 차량을 모델링 하였다. 교량은 3차원 프레임 요소와 3차원 탄성현수선 요소로 모델링하였다. 바닥판 상부의 조도를 실제의 도로로부터 얻은 스펙트럼으로부터 노면형상을 생성하여 사용하였다.

  • PDF

프리텐션을 받는 트러스 구조물의 좌굴을 고려한 최적설계 (Optimum Design of Truss Structures with Pretension Considering Bucking Constraint)

  • 김연태;김대환;이재홍
    • 한국강구조학회 논문집
    • /
    • 제22권2호
    • /
    • pp.197-208
    • /
    • 2010
  • 언더텐션이란 상부에서의 하중을 하부 케이블의 인장력을 이용하여 그 하중을 양 단부로 전달하는 시스템을 말하며 처짐과 부재 크기를 제어하기 위해 장스팬 구조물에 주로 적용된다. 하지만 수많은 단면 중에서 여러 조건을 만족하며 최소의 물량, 즉 최대의 경제성에 부합하는 최적의 단면을 찾는 것은 매우 어려운 일이다. 이에 본 연구에서는 마이크로 유전알고리즘을 이용하여 언더텐션 형태의 트러스 구조물에 단면 최적화 연구를 수행하였으며 처짐과 허용응력 그리고 좌굴이 제약조건으로 고려되었다. 최적화 검증 예제로 자주 사용되는 10-bar 트러스 예제의 이전 연구 결과와의 비교를 통하여 개발된 프로그램을 검증하였다. 이를 바탕으로 프리텐션 크기를 변수로 설정하여 언더텐션 구조물의 최적 설계를 수행하였다. 본 연구에서 제시된 최적설계 그래프를 통하여 설계자가 일정 조건을 만족하는 최적의 단면을 쉽게 선택할 수 있을 것으로 사료된다.