• Title/Summary/Keyword: Steel Water Pipe

Search Result 183, Processing Time 0.024 seconds

공업용수배관의 캐비테이션-침식특성에 관한 연구 ( 1 ) ( Study on the Charactistics of Cavitation Erosion for Industrial Water Piping ( 1 ) )

  • 김윤곤
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.4
    • /
    • pp.312-319
    • /
    • 1994
  • Recently, with the rapid development in the industries such as an iron mill and chemical plants, there is enlarged by the use of the piping. Sepecially, the piping connected with a fluid, if it is increase the speed of running fluid, ought to generate cavitation phenomenon with unbalanced pressure. So, the cavitation phenomenon cause serious damage of the piping, because it generate erosion and corrosion in the piping. In this study, the steel pipe piping water (SPPW) and SPPW on weldment were tested by using of cavitation-erosion test apparatus with nozzle and were investigated under the marine environment of liquid. (specific resistance : 25 $Omega$. cm) The main results obtained are as follows : 1) The total weight loss and weight loss rate of affected zone of weldment by corrosion-erosion in the sea water are more increased than that of base metal. 2) The electrode potential by corrosion-erosion in the sea water becomes less noble than that of base metal, and current density is more increased. 3) As time goes by, the total weight loss and weight loss rate by cavitation erosion-corrosion in air-liquid 2 phase flow become more increased then those in only liquid solution. but these values turn to be decreased.

  • PDF

Evaluation of Ground-Water Sampling Techniques for Analysis of Chlorofluorocarbons (지하수의 CFCs(Chlorofluorocarbons) 조사를 위한 시료 채취 방법의 평가)

  • 고동찬;이대하
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2003
  • Two types of ground-water sampling techniques for CFCs (chlorofluorocarbons) analysis, the cold-welded copper tube method and flame-sealed borosilicate glass ampule method, were compared and evaluated. CFCs concentrations by the copper tube method showed a poor reproducibility among triplicates whereas those by the glass ampule method showed a good agreement and relative standard deviations of triplicates were less than 5%. The poor reproducibility of the copper tube method appears to be attributed to the incomplete sealing in connection between faucets of wellhead and the sampling apparatus. The copper tube method also showed higher CFCs concentrations than the glass ampule method, which is more pronounced for CFC-11 than for CFC-12. The plastic tubings and rubber gasket of faucets in case of the copper tube method possibly contaminated the samples with CFC-11 and CFC-12. The potential of CFCs contamination for the glass ampule method was eliminated by using stainless steel and Nylon only and by connecting the sampling equipment directly to the main discharge pipe of wellhead. The validity of the glass ampule method were also verified by detecting very low level of CFCs for the ground-water sample which is old enough to have negligible CFCs.

Influences of pH on Heavy Metal Leaching in Water Supply Pipelines (상수도관내 중금속 용출에 대한 수소이온농도의 영향 평가 연구)

  • Lee, Jeongwon;Noh, Yoorae;Park, Joonhong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.73-82
    • /
    • 2017
  • In Korea, previous certification of water supply infrastructure was mainly focused on economical and physical aspects. Recently, hygienic safety of water supply service has become a sensitive and important issue to our people for evaluating the water quality with growth of economy and education system. According on water quality in 497 Korean water supply facilities, pH values in the supplied water have ranged between 5.8-8.5. However, little is known about metal leachability at the pH conditions observed in the real water supply systems because a fixed pH condition (pH 7.0) has been used in the current standard method, 'Hygienic Safety Testing Method', in water supply. In this work, we examined the effects on heavy metal leachability with pH differences in the water supply pipes which are typically used in Korea. As a result, the amounts of metal leachability were tended to increase when pH levels were decreased. Especially at pH 5.8, Cu leachability from Cu pipes was found to exceed the public health standard level even after applying a normalization factor (NF) given by the current Korea standard method. The Cr and Cu leached from stainless steel pipes, Cd, Pb, Cu, and Zn from Cu-based pipe fittings, and Zn from Zn-based pipe fittings were exceeded the Korean hygienic safety standards while, after applying the NF, concentrations of the leached metals were satisfied with the current Korean standard. The findings from this work provide implications on the needs of reforming the current hygienic safety standard methodology.

Effect of Surrounding Soil Properties on the Attenuation of the First Guided Longitudinal Wave Mode Propagating in Water-filled, Buried Pipes (주변 흙의 특성이 물이 찬 매립된 배관에서 전파되는 기본 유도 종파 모드 감쇠에 미치는 영향)

  • Lee, Ju-Won;Na, Won-Bae;Shin, Sung-Woo;Kim, Jae-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.32-37
    • /
    • 2010
  • This study presents the attenuation characteristics of the first guided longitudinal wave mode propagating in water-filled, buried steel pipes in order to investigate the effects of soil saturation and compaction on the attenuation patterns. For numerical calculation of attenuation, 10 different combinations of S-wave velocity, P-wave velocity, and soil densities were considered. From the attenuation dispersion curves, which were obtained using Disperse software, we determined that the attenuation decreases as saturation increases, whereas it increases as compaction increases. Over the frequency range from 0.2 to 0.4 MHz, the first longitudinal wave mode has attenuations that are relatively lower than for other ranges, is faster than the first flexural wave mode, and is sensitive to defects aligned in the axial direction. Hence, the first longitudinal wave mode over the mentioned frequency range would be the proper choice for long-range buried pipelines that transport water.

Investigation on electrochemical performance of Al anode material for marine growth prevention system

  • Kim, Seong-Jong;Jang, Seok-Ki;Han, Min-Su;Lee, Seung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.968-973
    • /
    • 2014
  • Aluminum anode of marine growth prevention system for ship is installed in seachest or sea water strainer. The Al anode is connected to a control panel that feeds a current to the anode. The dissolved ions produced by the anode are transferred in sea water, spreads through the sea water pipe system and creates a protective film in the pipelines. Thereby, corrosion in pipeline system significantly is reduced. In application on condition as a steel ship, the big accident can be caused by the corrosion. Accordingly, in this research, we evaluated influence of applied current and flow velocity on electrochemical characteristics of Al anode for marine growth prevention system (MGPS). Based on the results of the erosion-cavitation experiments, cavitation rate increased greatly until 120 min. of the experimental time and decreased a little at the point of 180 min. where pit grew and merging occurred but showed a tendency of steadily increasing consumption rates. Based on the results of the Tafel analysis, compared to static states, corrosion current densities show a rapidly increasing tendency when flow occurred.

A Study on the Seismic Protection Performance of Press Fittings for Light Gauge Stainless Steel Pipes (일반배관용 스테인리스강관에 대한 프레스식 관이음쇠의 내진성능에 관한 연구)

  • Baek, Yeal-Sun;Nam, Jun-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.65-70
    • /
    • 2017
  • The seismic performance of press fittings is studied, which is one of the weldless joints of stainless steel pipe used in the water piping of recent fire protection system. The piping of this study was constructed based on the piping connection reference of NFPA 13. The permissible displacement of the piping was set as the allowed amount which is given in the Building Structure Standard, and the measurements were repeated 10 times. The Von-mises stress of the piping was 2.48 and 1.25 times of the allowed amount of stress, which was less than the standard, noted three times on the NPPs Allowable Stress for Level D service loading. Therefore, the press fittings shows enough seismic performance.

Underground Heat Transfer Characteristics of the Underground Heating System for Soil Sterilization in Greenhouse (온실 내 토양소독을 위한 지중난방시스템의 지중 열전달 특성)

  • Park, Kyung-Kyoo;Ha, Yu-Shin;Hong, Dong-Hyuck;Jang, Seung-Ho;Kim, Jin-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.108-115
    • /
    • 2010
  • This study was conducted to estimate the optimum temperature and required time for soil sterilization when heated water was circulated through underground heating pipes in the greenhouse which solar heat was influenced to the temperature of soil during the summer day. Two different types of heating pipes were used for the experiment. One was a polyethylene pipe(XL) and the other was a corrugated ring shaped stainless steel pipe(STS). The results of the studies were summarized as follows; By measuring the thermal characteristics of the XL and STS, it was examined that the average temperature differences of the inlet and outlet were $8.5^{\circ}C$ and $13.3^{\circ}C$, the average flowrates were 15.3 L/min and 5.6 L/min, and the average radiation powers were 9.1 kW and 4.1 kW, respectively. As results of the regression analysis of underground temperatures, when average soil temperature was$35^{\circ}C$, an average water temperature was $80^{\circ}C$, and XL was used, it was estimated that the possible heat transfer distance, the required time for heat transfer and heat flux to reach the underground temperature of $60^{\circ}C$ were 300 mm, 230 hours, and $7.57kW/m^2$, respectively.

Temperature Crack Control in Slab Type구s Mass Concrete Structures (슬래브형 매스콘크리트 구조물의 온도균열제어)

  • 김동석;구본창;하재담;진형하;오승제;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.333-336
    • /
    • 1999
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as mat-slab of nuclear reactor buildings, dams or large footings, foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, pre-cooling which lowers the initial temperature of fresh concrete with ice flake, pipe cooling which cools the temperature of concrete with flowing water, design change which considers steel bar reinforcement, operation control and so on. The Aim of this paper is to verify the effect of low heat blended cement in reducing thermal stress in slab type's mass concrete such as container harbor structures.

  • PDF

A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection (소방용 강관배관 부식계수를 고려한 수리계산 적용방안에 관한 연구)

  • Mun, Chul-Hwan;Kang, Ho-Jung;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.69-77
    • /
    • 2020
  • With the recent enlargement and complication of buildings, damage caused by the incidents of fires breaking out are escalating. Consequently, the use of sprinkler facilities is increasing among water-based fire extinguishing systems. Piping materials used in fire prevention systems include carbon steel (for general or pressure pipeline), CPVC, copper, and stainless-steel. Among these, the steel and CPVC pipes, which are commonly employed in fire prevention, were considered for testing the reliability of the water-based systems. This analysis was performed using the PIPENET software to perform hydraulic calculations in order to examine the flow and pressure at the terminal head when the corrosion coefficient was applied; this coefficient was applied considering the aging of pipes. Assuming a uniform pipe diameter in the steel pipes, the rated flow in the pump installed on the first floor of the basement was reduced by over 10% after 20 years had passed (C value of 90); moreover, the reduction in pressure and flow at its terminal head exceeded 30% and 16.5%, respectively. The results indicate that it is difficult to ensure the reliability of these fire prevention facilities. Furthermore, according to our estimation, considering 30 years had passed (C value of 80), the rated flow of the pump was reduced by over 15%, and the corresponding reduction in pressure and flow at its terminal head exceeded 42% and 24%, respectively.

Development of Residual Tensile Strength Prediction Model for Metallic Water Pipes (상수도 금속관의 잔존 인장강도 추정모델 개발)

  • Bae, Chulho;Kim, Jeonghyun;Woo, Hyungmin;Hong, Seongho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.17-28
    • /
    • 2008
  • In this study, the residual strength prediction models were proposed by measuring various residual strength according to pit characteristics for metallic water pipes such as cast iron pipe (CIP), ductile iron pipe (DIP), and steel pipe (SP). The exponential prediction model was better fitted to measured residual tensile strength for CIP. In case of DIP and SP, the prediction model using loss of strength was more exactly predicted compared with other model types. The fracture toughness were averagely $40.46kgf/mm^2{\sqrt{mm}}$ for CIP, $85.27kgf/mm^2{\sqrt{mm}}$ for DIP, and $92.27kgf/mm^2{\sqrt{mm}}$ for SP, the determination coefficient ($R^2$) of between measured residual tensile strength and predicted values for residual strength prediction models using fracture toughness was estimated from 0.44 to 0.86. Especially, the proposed residual tensile strength prediction models were applied for the verification and reliability to CIPs and DIPs at 14 sites. The determination coefficient ($R^2$) between measured residual tensile strength and predicted values was estimated from 0.76 to 0.78. Therefore it was thought that the proposed residual tensile strength models could help to support resonable and economical decision of rehabilitation/replacement.

  • PDF