• Title/Summary/Keyword: Steel Tubular Column

Search Result 197, Processing Time 0.02 seconds

Fatigue of tubular steel lighting columns under wind load

  • Peil, U.;Behrens, M.
    • Wind and Structures
    • /
    • v.5 no.5
    • /
    • pp.463-478
    • /
    • 2002
  • Lighting and traffic signal columns are mainly stressed by excitation due to natural, gusty wind. Such columns typically have a door opening about 60 cm above ground level for the connection of the buried cable with the column's electric system. When the columns around this notch are inadequately designed, vibrations due to gusty winds will produce considerable stress amplitudes in this area, which lead to fatigue cracks. To give a realistic basis for a reliable and economic design of lighting and traffic signal columns, a number of experimental and theoretical investigations have been made. The proposed design concept allows the life of such columns to be assessed with a satisfactory degree of accuracy.

Axial compression behavior of circular recycled concrete-filled steel tubular short columns reinforced by silica fume and steel fiber

  • Chen, Juan;Liu, Xuan;Liu, Hongwei;Zeng, Lei
    • Steel and Composite Structures
    • /
    • v.27 no.2
    • /
    • pp.193-200
    • /
    • 2018
  • This paper presents an experimental work for short circular steel tube columns filled with normal concrete (NAC), recycled aggregate concrete (RAC), and RAC with silica fume and steel fiber. Ten specimens were tested under axial compression to research the effect of silica fume and steel fiber volume percentage on the behavior of recycled aggregate concrete-filled steel tube columns (RACFST). The failure modes, ultimate loads and axial load- strain relationships are presented. The test results indicate that silica fume and steel fiber would not change the failure mode of the RACFST column, but can increase the mechanical performances of the RACFST column because of the filling effect and pozzolanic action of silica fume and the confinement effect of steel fiber. The ultimate load, ductility and energy dissipation capacity of RACFST columns can exceed that of corresponding natural aggregate concrete-filled steel tube (NACFST) column. Design formulas EC4 for the load capacity NACFST and RACFST columns are proposed, and the predictions agree well with the experimental results from this study.

Tests and numerical analysis on octagonal concrete-filled double skinned steel tubular short columns under axial compression

  • Manigandan R
    • Steel and Composite Structures
    • /
    • v.50 no.5
    • /
    • pp.499-513
    • /
    • 2024
  • This paper describes the experimental and numerical investigations of octagonal Concrete-Filled Double Skinned Steel Tube (CFDST) short columns under the influence of various internal sizes of the circular and square steel tubes, with constant cross-sectional dimensions of the external octagonal steel tube under concentric loading. The non-linear finite element analysis of octagonal CFDST columns was executed using the ABAQUS to forecast and compare the axial compression behavior influenced by the various sizes of internal circular and square steel tubes. The study shows that the axial compressive strength and ductility of octagonal CFDST columns were significantly influenced by various internal dimensions of the circular and square steel tubes with the strengths of constituent materials.

Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load (반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동)

  • Kang, Chang-Hoon;Moon, Tae-Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.387-395
    • /
    • 2000
  • The purpose of this research is to evaluate the capacity of strength and plastic deformation of those members, and provide experimental data on the seismic behavior of these members as a basis for developing guidelines for designing seismically resistant concrete-filled steel tubular columns. Eighteen cantilever-type specimens were tested under constant axial load and cyclically lateral load as models of bottom columns in high-rise building. The parameters studied in the test program included, are width-thickness ratio of steel tube, slenderness ratio (Lo/D) and axial force ratio. From the test results, the effects of parameters on the strength, the deformation capacity, energy absorption capacity are discussed. The specimen flexural capacity under combined axial and lateral loading was found to be almost accurately predicted by criteria AIJ and AISC-LRFD providing conservative results. Therefore KSSC for encased composite column can be applied to the concrete filled column if composite section and elastic modulus are modified according to AIJ and AISC-LRFD. Finally, the proposed flexural capacity considering confinement effects is a food agreement on the tests results.

  • PDF

Confining effect of concrete in double-skinned composite tubular columns

  • Won, Deok Hee;Han, Taek Hee;Kim, Seungjun;Lee, Jung-Hwa;Kang, Young-Jong
    • Computers and Concrete
    • /
    • v.14 no.5
    • /
    • pp.613-633
    • /
    • 2014
  • A double-skinned composite tubular (DSCT) column, which consists of concrete and inner and outer tubes, was finally developed to overcome the weaknesses of concrete filled tube columns by reducing the self-weight of the column and confining the concrete triaxially. Research pertaining to the stiffness and strength of the column and the confining effect in a DSCT column has been carried out. However, detailed studies on the confining stress, especially the internal confining stress in a DSCT column, have not been carried out. Internal and external confining stresses should be evaluated to determine the effective confining stress in a DSCT column. In this paper, the confining stresses of concrete before and after insertion of an inner tube were studied using finite element analysis. The relationship between the internal or external confining stresses and the theoretical confining stress was investigated by parametric studies. New modified formulae for the yield and buckling failure conditions based on the formulae suggested by former researchers were proposed. Through analytical studies, the modified formulae were verified to be effective for economic and reasonable design of the inner tubes in a DSCT column under the same confining stress.

Non-linear Analysis of Full Scaled CFT Column to H-Beam Connections with T-Stiffeners (T 스티프너를 이용한 CFT기둥-H 형강보 실대형 접합부의 비선형 해석)

  • Lee, Seung Woo;Kim, Young Joo;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.835-843
    • /
    • 2002
  • The goal of this paper is to understand the stress-transfer mechanism of concrete-filled tubular column to H-beam connection with external T stiffener through the elasto-plastic finite element method and to offer basic data for the design of T stiffener. For the accuracy, analysis results are compared with experimental results. It makes use of several stress and strain indices to understand the stress-transfer mechanism of connection. An alternative plan that decreases the stress concentration of beam flange to horizontal stiffener connection is proposed through the elasto-plastic finite element method.

Buckling resistance of axially loaded square concrete-filled double steel tubular columns

  • Ci, Junchang;Ahmed, Mizan;Tran, Viet-Linh;Jia, Hong;Chen, Shicai;Nguyen, Tan N.
    • Steel and Composite Structures
    • /
    • v.43 no.6
    • /
    • pp.689-706
    • /
    • 2022
  • Thin-walled square concrete-filled double steel tubular (CFDST) columns composed of the inner circular tube filled with concrete can be used to carry the large axial loads or strengthen existing CFST columns in composite constructions. This paper reports an experimental program carried out on short square CFDST columns loaded concentrically. The influences of important column parameters on the post-buckling performance of such columns are investigated. Test results exhibit that the inner circular tube significantly improves the ultimate loads and the ductility of such columns compared to conventional concrete-filled steel tubular (CFST) and double-skin CFST (DCFST) columns with an inner void. A mathematical model developed is used to simulate the ultimate strengths and load-strain curves of such columns loaded axially. Furthermore, the ultimate strengths of such columns are predicted using existing codified design models for conventional CFST columns as well as the formulas proposed by previous researchers and compared against a large database comprising 500 CFDST columns. Lastly, an accurate artificial neural network model is developed for the practical applications of such columns under axial loading.

Experimental studies and numerical analysis of the shear behavior of fin plates to tubular columns at ambient and elevated temperatures

  • Jones, M.H.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.179-200
    • /
    • 2008
  • This paper reports the results of a recent experimental study into the behavior of welded fin-plate connections to both hollow and concrete filled tubular (CFT) columns under shear. Experiments have been performed at both ambient and elevated temperatures with the aid of an electric kiln. The observed failure modes include fracture of the fin plate and tearing out of the tube around the welds. By considering the results of previously published research, the current design method for similar connections under purely tensile load, in CIDECT Guide 9, based on a deformation limit of 3% of the tube width is shown to be inadequate when evaluating the ultimate strength of such connections. By comparing the results from the current test program which failed in the fin-plate with Eurocode guidance for failure of a fin-plate alone under shear and bending load it is shown that the column face influences the overall connection strength regardless of failure mode. Concrete in-fill is observed to significantly increase the strength of connections over empty specimens, and circular column specimens were observed to exhibit greater strength than similarly proportioned square columns. A finite element (F.E.) model, developed using ABAQUS, is presented and validated against the experimental results in order that extensive parametric tests may be subsequently performed. When validating the model against elevated temperature tests it was found that using reduction factors suggested in published research for the specific steel grades improved results over applying the generic Eurocode elevated temperature steel strength reduction factors.

A Numerical Study on the Semi-Rigid Behavior of Steel Tubular Column to H Beam Connection with Exterior Square-Plate Diaphragms (직각판형 외다이아프램 각형강관기둥-H형강보 접합부의 방강접거동에 관한 해석적연구)

  • Chae, Yong-Soo;Choi, Sung-Mo;Kim, Dong-Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.3
    • /
    • pp.289-299
    • /
    • 2001
  • The purpose of this study was to analyze the characteristics of semi-igid behavior of the steel tubular column to H-beam connection reinforced with exterior square-plate diaphragms and to check the main parameters that affect this behavior. Steel tube connections without interior diaphragm and/or complicated exterior diaphragm show the considerable flexibility due to out of-plane deformation of tube flange. For the exact analysis well-reflected the effect of this flexibility on the overall frame performance. it need to find out the moment-rotation curve function that well trace the result of experiment in the whole region and the function should be simply transformed into an adequate form for the nonlinear analysis program. After collecting several test data same to the connection type considered. we carried out FEM analysis using ANSYS for the assumed beam-to-column connection developed from the simple tension test and the results are compared with experimental values. Based on the parametric study. we proposed the moment-relation curve function and performed the multiple-regression analysis procedure for three parameters consisting of this function with the main geometric parameter of this connection type.

  • PDF

Numerical and experimental analysis on the axial compression performance of T-shaped concrete-filled thin-walled steel

  • Xuetao Lyu;Weiwei Wang;Huan Li;Jiehong Li;Yang Yu
    • Steel and Composite Structures
    • /
    • v.50 no.4
    • /
    • pp.383-401
    • /
    • 2024
  • The research comprehensively studies the axial compression performance of T-shaped concrete-filled thin-walled steel tubular (CTST) long columns after fire exposure. Initially, a series of tests investigate the effects of heating time, load eccentricity, and stiffeners on the column's performance. Furthermore, Finite Element (FE) analysis is employed to establish temperature and mechanical field models for the T-shaped CTST long column with stiffeners after fire exposure, using carefully determined key parameters such as thermal parameters, constitutive relations, and contact models. In addition, a parametric analysis based on the numerical models is conducted to explore the effects of heating time, section diameter, material strength, and steel ratio on the axial compressive bearing capacity, bending bearing capacity under normal temperature, as well as residual bearing capacity after fire exposure. The results reveal that the maximum lateral deformation occurs near the middle of the span, with bending increasing as heating time and eccentricity rise. Despite a decrease in axial compressive load and bending capacity after fire exposure, the columns still exhibit desirable bearing capacity and deformability. Moreover, the obtained FE results align closely with experimental findings, validating the reliability of the developed numerical models. Additionally, this study proposes a simplified design method to calculate these mechanical property parameters, satisfying the ISO-834 standard. The relative errors between the proposed simplified formulas and FE models remain within 10%, indicating their capability to provide a theoretical reference for practical engineering applications.