• 제목/요약/키워드: Steel Concrete Plate

검색결과 673건 처리시간 0.021초

탄소섬유시트로 보강된 R/C 보의 최대내력에 관한 연구 (A Study on the Maximum Load of R/C Beams Strengthened by Carbon Fiber Sheets)

  • 최창식;김용채
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.199-204
    • /
    • 2001
  • Recently, strengthening of structural members by adhesion of steel plate or fiber sheets is generally used. Particularly, the Carbon Fiber Sheets (CFS) is widely used. Rut, the strengthening effect of the CFS is not clearly define yet. Therefore, this paper is designed to evaluate the effectiveness of CFS methods by analyzing previous studies in statistics. According to the results, the maximum load carrying capacity is increased up to 0.16 times when the reinforced concrete beams were strengthened by CFS which is standard specimens. The number of sheets made some effect on the strength while, the other parameters influenced the ductile capacity.

  • PDF

콘크리트충전 강관기둥의 성능향상을 위한 내면부착 beam의 형상 연구 (A Study on the Shape of Beam Attached CFT inner-side for Developing Column's Performance)

  • 이동운;윤혁기;김대건
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2015
  • The CFT(Concrete Filled Tube) system has been developed to behave well in a structural performance such as stiffness, stress, ductility, fire resistance that is derived from its mechanical advantages of composite structure. There were number of studies about unprotected CFT columns for improving their fire resistance through reinforcing bars or plates being placed inside the steel tube. It was also known that reinforcing plates of flat type need stiffeners in a certain distance to avoid their buckling failure so it cost as much as their using consequentially. This paper is planned to test the work of beam elements attached inner side of CFT depending on its shape. More discussions on beam's design could be followed after some fire tests accordingly conducted within this project.

  • PDF

복합 트러스 교량의 연결구조에 대한 실험적 연구 (An Experimental Study on Joint Structures of Composite Truss Bridges)

  • 심창수;박재식;김광수
    • 한국강구조학회 논문집
    • /
    • 제19권3호
    • /
    • pp.303-312
    • /
    • 2007
  • 경간 40m~100m 정도 경간에 대해 일반적으로 강 박스 거더교에 대한 설계가 이루어지고 있다. 상부구조의 자중을 줄이기 위해서 복합트러스 교량에서 복부의 콘크리트 웹 대신에 강 사재가 사용되고 있다. 이러한 복합트러스 교량의 설계 시 가장 중요한 부분 중의 하나가 콘크리트 상 하부를 연결하는 연결부의 형태이다. 이러한 접합부는 외부에서 작용하는 조합하중을 분담해야하는데, 아직 이러한 접합구조에 대한 명확한 설계기준이 없는 실정이다. 한계상태에서 격점부의 하중전달에 대한 명확한 연구와 설계방법에 대한 조사가 필요하다. 콘크리트 상 하부를 연결하는 격점부 사재는 다양한 연결형태가 있다. 이번 논문에서는 거셋 플레이트에 용접되어진 그룹 스터드 연결재에 관한 연구가 수행되었다. 25mm 절곡 스터드를 사용하여 수행된 전단실험을 통하여 현재의 스터드 간 최소기준 간격을 만족하는 상태에서는 현재의 설계 규정을 사용할 수 있음을 밝혔다. 휨-전단 실험을 통해서는 조합하중이 작용하는 격점부의 상세를 개선하였다. 격점부의 인발강도를 증진시키기 위해서 절곡 스터드가 제안되었고 그룹 스터드의 최 외측 스터드에 적용되었다. 이러한 결과들을 바탕으로 복합 트러스 교량의 개선된 격점부 상세가 개선되고 설계 방안이 제안되었다.

LNG외조를 구성하는 샌드위치 콘크리트 패널의 충돌거동해석 (Collision Behaviors Analysis of Sandwich Concrete Panel for Outer Shell of LNG Tank)

  • 이계희
    • 한국전산구조공학회논문집
    • /
    • 제30권6호
    • /
    • pp.485-493
    • /
    • 2017
  • 본 연구에서는 LNG 저장시설의 외조를 구성하는 SCP(sandwich concrete panel)에 대한 충돌해석을 수행하고 그 거동을 분석하였다. 설계기준 중 하나인 BS7777에서 제시하는 충돌에너지와 동일한 값을 갖도록 두 종류의 충돌체와 다양한 충돌속도를 이용하여 충돌조건을 구성하고 이에 대한 비선형동적 해석모델을 구성하여 설정된 충돌조건에 대하여 수치해석을 수행하였다. 또한 1차 충돌 후에 동일한 지점에 같은 충돌에너지를 가진 2차 충돌이 일어나는 것을 가정하여 충돌거동을 분석하였다. 해석결과 동일한 충돌에너지를 갖는 충돌에서 충돌체의 크기가 작고, 충돌속도가 작을수록 큰 변형이 발생하는 것으로 나타났다. 충돌에너지는 외측강판과 내부 충진콘트리트가 6:4정도의 비율로 소산시키는 것으로 나타났다. 중복충돌해석에서는 2차 충돌체의 크기에 따라 최종충돌변형이 지배되는 것으로 나타났고 2차 충돌에 의한 변형량은 1차 충돌에 비하여 적은 값을 나타냈는데 이는 강판의 막거동 때문인 것으로 분석되었다. 이격된 중복충돌에서는 이격위치와 관계없이 2차 충돌점에서 가장 큰 변형이 발생하는 것으로 나타났다.

Bonding between high strength rebar and reactive powder concrete

  • Deng, Zong-Cai;Jumbe, R. Daud;Yuan, Chang-Xing
    • Computers and Concrete
    • /
    • 제13권3호
    • /
    • pp.411-421
    • /
    • 2014
  • A central pullout test was conducted to investigate the bonding properties between high strength rebar and reactive powder concrete (RPC), which covered ultimate pullout load, ultimate bonding stress, free end initial slip, free end slip at peak load, and load-slip curve characteristics. The effects of varying rebar buried length, thickness of protective layer and diameter of rebars on the bonding properties were studied, and how to determine the minimum thickness of protective layer and critical anchorage length was suggested according the test results. The results prove that: 1) Ultimate pull out load and free end initial slip load increases with increase in buried length, while ultimate bonding stress and slip corresponding to the peak load reduces. When buried length is increased from 3d to 4d(d is the diameter of rebar), after peak load, the load-slip curve descending segment declines faster, but later the load rises again exceeding the first peak load. When buried length reaches 5d, rebar pull fracture occurs. 2) As thickness of protective layer increases, the ultimate pull out load, ultimate bond stress, free end initial slip load and the slip corresponding to the peak load increase, and the descending section of the curve becomes gentle. The recommended minimum thickness of protective layer for plate type members should be the greater value between d and 10 mm, and for beams or columns the greater value between d and 15 mm. 3) Increasing the diameter of HRB500 rebars leads to a gentle slope in the descending segment of the pullout curve. 4) The bonding properties between high strength steel HRB500 and RPC is very good. The suggested buried length for test determining bonding strength between high strength rebars and RPC is 4d and a formula to calculate the critical anchorage length is established. The relationships between ultimate bonding stress and thickness of protective layer or the buried length was obtained.

Basalt 섬유쉬트의 철도시설 콘크리트구조물 보강재로서의 부착거동 연구 (Bonding Characteristics of Basalt Fiber Sheet as Strengthening Material for Railway Concrete Structures)

  • 박철우;심종성
    • 한국철도학회논문집
    • /
    • 제12권5호
    • /
    • pp.641-648
    • /
    • 2009
  • 최근 철도차량의 속도가 증가함에 따라 철도시설물에도 철근콘크리트 구조물이 많이 적용되고 있는 실정이다. 하지만 이러한 콘크리트 구조물은 공용년수의 증가에 따라 필연적으로 구조적인 보강이 요구된다. 강판보강법 및 섬유복합체(FRP)를 활용한 보강법 등이 가장 일반적으로 적용되는 실정이지만 각 공법마다 나름대로의 단점 역시 존재 한다. 최근 화재나 기타 환경적인 공격에 대하여 강한 내구성을 가진 재료의 개발이 요구되고 있으며 이에 따른 현무암으로부터 추출한 Basalt 섬유를 활용한 섬유보강재가 많은 관심을 받고 있다. 이에 본 연구에서는 Basalt 섬유쉬트를 보강재로 사용할 경우 중요한 특성인 콘크리트와의 부착특성에 관하여 연구를 수행하였다. 실험변수는 보강폭, 길이, 보강겹수를 포함한다. 실험결과, 파괴형태는 계면파괴, 섬유파단, 그리고 rip-off의 형태가 관측되었으며 보강길이보다는 보강폭이 보강강도에 더 많은 영향을 미치는 것으로 판단되었다. 또한 보강길이가 전부 유효하게 작용하지는 않았으며 이에 유효보강길이를 산정하고 이에 따른 부착강도를 산정하였다. 이를 다른 종류의 FRP재료를 활용한 경우에 유효 보강길이와 비교하여 Basalt 섬유쉬트의 부착특성을 분석하였다.

2층도로용 강구조 덱 시스템의 최적설계 (Optimum Design of Steel-Deck System for Two-Story Roads)

  • 조효남;민대홍;김현우
    • 한국강구조학회 논문집
    • /
    • 제10권3호통권36호
    • /
    • pp.553-564
    • /
    • 1998
  • 최근도심지의 극심한 교통체증의 해소를 위한 방안으로 2층도로 강구조 덱 시스템의 채택이 증가하고 있다. 그 주된 이유는 신속한 시공과 콘크리트덱에 비하여 자중의 감소효과가 크고 보다 큰 강도와 효율적인 가설이 가능하기 때문이다. 본 연구의 목적은 강구조 덱 시스템의 최적설계프로그램을 이용한 2층도로용 강구조 덱 시스템의 가장 합리적인 형식 결정에 관한 연구이다. 최적화의 목적함수는 최소 초기비용으로 정식화하였다. 설계 제약조건은 도로교시방서의 ASD설계기준에 맞추어 정식화하였으며 최적설계과정은 두 단계로 이루어져 있다. 첫 번째 단계는 박스 또는 플레이트주형에 대한 강구조 덱 시스템의 최적설계가 수행된다. 그리고 두 번째 단계에서 개단면 또는 폐단면리브를 갖는 강상판에 대하여 최적설계를 한다. 최적설계 프로그램의 구조해석은 주형에 대하여 격자해석 모델링을 이용하였고 강상판에 대해서는 Pelican-Esslinger법을 사용하였다. 최적화 기법은 SQP를 이용하였다. 적용 예의 각 형식별 강구조 덱 시스템의 최적설계 결과의 비교를 통하여 비용의 효율성을 검토하였고 폐단면리브를 가지는 직선 형상의 박스거더 형식이 가장 효율적이고 경제적으로 판단된다.

  • PDF

볼트접합 앵글을 사용한 합성기둥의 중심축 압축실험 (Axial Load Test of Prefabricated Composite Columns Using Bolt-connected Steel Angles)

  • 김현진;황현종;박홍근;김동관;양종민
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.147-158
    • /
    • 2017
  • 본 연구에서는 볼트조립 앵글을 적용한 선조립 합성기둥(이하 PSRC 합성기둥)의 압축성능을 연구하였다. 2/3 축소비율의 PSRC 기둥실험체 4개와 기존 SRC 기둥실험체 2개에 대하여 중심축 압축실험을 수행하였다. 횡보강재의 수직간격 및 단면형상과 앵글의 단면형상을 실험변수로 고려하였다. 실험결과, PSRC 기둥실험체는 기존 SRC 기둥실험체와 비교하여 비슷한 압축하중 재하능력 및 변형능력을 발휘하였다. PSRC 합성기둥의 경우, 횡방향 강판의 좁은 횡보강 간격과 Z형 단면의 강판이 압축강도 및 변형능력 향상에 효과적인 것으로 나타났다. 또한 PSRC 합성기둥은 현행설계기준에 의한 공칭 압축강도보다 큰 압축하중 재하능력을 나타내었다. 실험체들에 대한 수치해석결과는 피복 콘크리트 탈락으로 인한 하중감소를 제외하고 초기강성 및 하중재하능력을 비교적 잘 예측하였다.

하이브리드 프리캐스트 보-기둥 접합부의 해석적 연구 (Analytical Study on Hybrid Precast Concrete Beam-Column Connections)

  • 최창식;김승현;최윤철;최현기
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.631-639
    • /
    • 2013
  • 이 연구에서는 기존에 수행된 시공성과 경제성이 향상되고 중진 지역에서 사용 가능한 새로운 프리캐스트 콘크리트 보-기둥 접합상세의 비선형 유한요소해석이 수행되었다. 해당 상세는 복합구조를 기반으로 함으로써 기둥 내에는 각관을 보유하고 있으며 보에는 강판이 매입되어 있는 복잡한 단면을 보유하고 있다. 또한 콘크리트와 강재뿐만 아니라 ECC라는 새로운 재료를 사용함에 따라 요소의 선택 및 재료모델의 결정에 대한 방법론을 제시하였다. 비선형 유한요소해석은 상용 유한요소해석 프로그램인 ABAQUS를 통해 수행되었으며 요소 및 재료 모델은 ABAQUS에서 제공하는 모델들을 사용하였다. 비선형 유한요소해석 결과 기 수행되었던 실험 결과에 유사하거나 보수적으로 평가함으로써 변수분석에 사용할 수 있을 것으로 판단하였다. 구축된 유한요소해석 모델을 통해 해당 상세의 성능에 대한 압축력의 영향, 휨강도비의 영향에 대해 분석하였다. 압축력의 경우 기둥 압축강도의 10~20%에서 가장 좋은 성능을 발휘할 수 있었으며, 휨강도비 1.2 이상에서 기둥의 항복 없이 보의 소성힌지를 유도할 수 있음을 확인하였다.

콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능 (Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections)

  • 박창희;이철호;박홍근;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권4호
    • /
    • pp.503-514
    • /
    • 2011
  • 본 연구에서는 콘크리트채움 U형 합성보와 H형강 기둥 십자형 합성접합부의 내진상세를 제시하고, 2개의 실물대 실험체를 설계/제작하여 강구조내진기준의 표준실험절차에 따라 내진성능을 평가하였다. 주요 실험체 구성요소는 춤 450mm(실험체 A) 및 550mm(실험체 B) U형 강재보, 두께 165mm의 골데크플레이트 위에 타설된 콘크리트 바닥슬래브, U형보의 완전합성작용을 하기 위한 전단스터드, 부모멘트 전달을 위한 4개의 주철근 및 H형강 기둥에 정착을 위한 용접커플러 그리고 접합부 보강을 위한 보강판으로 구성된다. 순수 강재 보-기둥 접합부와 상이한 U형 합성접합부의 독특한 특성을 고려하여, 지진하중 하에서 내진성능에 결정적 영향을 미치는 보-기둥 접합부의 용접부 취성파단, 강판의 국부좌굴, 주철근의 휨좌굴, 콘크리트 압괴 등의 한계상태가 적절히 제어되도록 실험체를 설계하였다. 강구조내진기준의 지진하중 가력프로그램에 따른 실험결과, 설계에서 의도한 바와 같이 여러 한계상태가 적절히 제어되어 실험체 A 및 B는 각각 6% 및 6.8% 라디안에 이르는 매우 뛰어난 층간변형능력을 발휘하였다. 이는 특수모멘트골조에 요구되는 4% 라디안 수준을 충분히 상회하는 만족스런 층간변형능력이다. 특히 접합부 강화전략에 의해 제안된 합성접합부 상세는 설계에서 의도한 것과 같이 소성힌지를 보강단부로서 밀어냄으로서 취약할 수 있는 보-기둥 용접접합부를 효과적으로 보호하였다. 실험체 A의 최종 파괴모드는 6.0% 층간변위에서 발생한 보강단부에 인접한 냉간성형 코너부의 점진적 저사이클피로에 의한 하부플랜지의 파단에 의해 발생하였다. 한편, 실험체 B는 8.0%의 높은 수준의 층간변위에서 발생한 볼트이음부 파단에 의해 내력을 상실하였다.