• 제목/요약/키워드: Steel water pipe

검색결과 183건 처리시간 0.027초

수도용 대형 강관 용접부의 응력분포에 미치는 각장(leg of fillet)의 영향 (Effect of leg of fillet on stress distribution in weldments of large steel water pipes)

  • 김성도;배강열;나석주
    • Journal of Welding and Joining
    • /
    • 제10권3호
    • /
    • pp.54-62
    • /
    • 1992
  • Large steel water pipes are joined prevalently by bell and method and welded at inside and outside of lapped parts. According to the Korean Standard(KS) for fabrication of water pipes, the weldments are designed to have the length of leg which is same as or larger than the thickness of the pipe. It is recently pointed out that the standard size of weldments is too large, which results in an excessive consumption of material and labor. In this study, several cases of weldments having different sizes were investigated to reduce the length of leg to the effective size. For each case, the analysis of stresses was carried out to evaluate the safety of the welded pipes by using a package program, ANSYS, under the consideration of the loading condition of water pipes which includes the soil pressure on the pipe, the load over the road, and temperature change of the pipe. The results of this study revealed that the weldment which has the length of leg of the size over 0.7*thickness of the pipe could provide a stress level below the yield strength. Especially when the length of leg is 85% of the wall thickness, the maximum equivalent stress is only slightly higher than that of the leg of fillet of the size of 1.0*pipe thickness.

  • PDF

해상교량기초용 대형원형강관 가물막이의 동적 안정성 모니터링을 위한 실내모형실험 (Small-Scaled Laboratory Experiments for Dynamic Stability Monitoring of Large Circular Steel Pipe Cofferdam of Marine Bridge Foundation)

  • 박민철;이종섭;김동호;유정동
    • 한국지반공학회논문집
    • /
    • 제35권12호
    • /
    • pp.123-134
    • /
    • 2019
  • 본 연구의 목적은 충격에 의한 모형 원형강관의 동적 반응을 조사하는 것이며, 선박충돌에 의한 대형원형강관의 동적 안정성 모니터링을 위한 기초연구로써 수행되었다. 실내실험은 직경, 두께, 높이가 각각 30cm, 0.4cm, 90cm인 스테인레스 재질의 단본 모형 원형강관과 3개의 세그먼트를 볼트로 조립한 모형 원형강관으로 수행되었다. 각 세그먼트의 높이는 30cm이다. 대형원형강관이 해상에 설치된 것을 모사하기 위하여 모형 원형강관을 가로, 세로, 높이가 각각 1m인 토조에 설치하였으며, 흙의 높이는 23cm로 하였다. 선박 충돌을 모사하기 위하여 모형 원형강관을 해머로 타격하였으며, 토조 내의 수위를 25cm, 40cm, 55cm, 70cm로 변화시키면서 모형 원형강관의 동적 반응 특성을 비교하였다. 실험결과, 수위가 증가할수록 측정된 신호의 에너지가 감소하였으며, 단본의 모형 원형강관보다 볼트로 조립된 모형 원형강관이 더 큰 감소폭을 보였다. 주파수 특성의 경우, 단본 모형 원형강관에서 측정된 주파수 신호는 수위가 증가할수록 우세 주파수가 감소하는 경향을 보였다. 볼트로 조립된 모형 원형강관의 경우도 수위가 증가할수록 우세 주파수가 감소하였다. 하지만, 수위에 따른 우세 주파수의 감소폭이 상대적으로 작았으며, 수위가 상부 세그먼트에 접할 때 높을 때 급격한 감소를 보였다. 본 연구의 결과는 가속도계로 측정된 신호의 에너지와 주파수 변화 특성이 해상교량기초용 가물막이 대형원형강관의 동적 안정성 모니터링에 유용하게 활용될 수 있음을 보여준다.

급수관에서 관재에 따른 부식특성과 미생물 재성장 고찰 (Influence of Pipe Materials on Corrosion and Bacteria Regrowth in A Model Home Plumbing System)

  • 김태현;이윤진;이환;이철효;안교철;이우식
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.121-128
    • /
    • 2007
  • This study performed in order to evaluate the effects of pipe materials on corrosion and bacteria regrowth using a laboratory scale batch test. Two varieties of feed water with different microbial conditions were selected: tap water, surface river water (Han River water), and five pipe materials; carbon steel, copper, galvanized iron, stainless steel, and PVC, Carbon steel and galvanized iron pipes showed higher corrosion rates than other materials. In terms of attached bacterial growth, pipes with PVC and stainless steel showed higher bacteria concentration compared to other materials. Pseudomonas vesicularis was the predominant bacteria found on biofilm. The behavior of bacterial growth in the pipes was observed using a scanning electron microscope.

토양의 함수율에 빠른 상수도용 도복장 강관의 부식거동에 관한 연구 (Corrosion behavior of coated steel pipes for water works with water content of soil)

  • 박경화;배정효;하태현;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.227-229
    • /
    • 2004
  • The corrosion rate of buried steel pipes for water works was investigated under soil environment. Steel pipe shows various characteristics caused by complicated environment condition of underground and especially the corrosion rate of it depends on the resistivity of soil controlled by content of water. In this paper, the corrosion behavior of steel pipe was observed by polarization test under soil and the silica sand in the water content range of 0-50%. Generally it is well known that the resistivity of soil decreased rapidly over 15% water content. In fact the corrosion rate, corrosion potential, and corrosion consumption (MPY) of steel pipe were shown very different aspects within 20% water content.

  • PDF

상·하수 배관재의 수 환경에서 부식진전도 연구 (Research of Corrosion Growth Degree According in Liquid Environment of Waterworks and Sewer Piping Material)

  • 박경동;기우태;유형주;김동욱
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.33-40
    • /
    • 2006
  • The quality of the supply water which is supplied to consumer is not the thing of water after filtrating but the thing of water from faucet through pipe. As a result, heavy metals and microorganism, that is the major materials, which cause the distrust of the supply water is generated by supply process. Especially, the heavy metal is generated by the corrosion of waterworks. Besides, rupture by corrosion of pipe becomes the factor of supply water's pollution in waterworks and the factor of pollution of the soil and environment in drain pipe. Therefore, this research examined the weight reduction electric potential measure to measure the corrosion degree of piping materials after testing the corrosion of piping materials(Copper Pipe, Galvanized Steel Pipe, Stainless Steel Pipe) which is generally used at the moment in various corrosion environments(subterranean water, supply water, 3.5% NaCl, 3.5% $HNO_3$). And let me show basic design data about problem occurrence such as leakage water, rust water, inside and outside corrosion from this.

  • PDF

대구경 상수도관 부식 손상부의 고분자 필러와 복합슬리브 성능 평가 (Performance assessment of polymeric filler and composite sleeve technique for corrosion damage on large-diameter water pipes)

  • 이호민;박정수;박정주;배철호
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.203-214
    • /
    • 2023
  • In this study, the physical properties and fracture characteristics according to the tensile load are evaluated on the materials of the polymeric filler and carbon fiber-based composite sleeve technique. The polymeric filler and the composite sleeve technique are applied to areas where the pipe body thickness is reduced due to corrosion in large-diameter water pipes. First, the tensile strength of the polymeric filler was 161.48~240.43 kgf/cm2, and the tensile strength of the polyurea polymeric filler was relatively higher than that of the epoxy. However, the tensile strength of the polymeric filler is relatively very low compared to ductile cast iron pipes(4,300 kgf/cm2<) or steel pipes(4,100 kgf/cm2). Second, the tensile strength of glass fiber, which is mainly used in composite sleeves, is 3,887.0 kgf/cm2, and that of carbon fiber is up to 5,922.5 kgf/cm2. The tensile strengths of glass and carbon fiber are higher than ductile cast iron pipe or steel pipe. Third, when reinforcing the hemispherical simulated corrosion shape of the ductile cast iron pipe and the steel pipe with a polymeric filler, there was an effect of increasing the ultimate tensile load by 1.04 to 1.06 times, but the ultimate load was 37.7 to 53.7% compared to the ductile cast iron or steel specimen without corrosion damage. It was found that the effect on the reinforcement of the corrosion damaged part was insignificant. Fourth, the composite sleeve using carbon fiber showed an ultimate load of 1.10(0.61T, 1,821.0 kgf) and 1.02(0.60T, 2,290.7 kgf) times higher than the ductile cast iron pipe(1,657.83 kgf) and steel pipe(2,236.8 kgf), respectively. When using a composite sleeve such as fiber, the corrosion damage part of large-diameter water pipes can be reinforced with same level as the original pipe, and the supply stability can be secured through accident prevention.

강관 토목구조물이 설치된 지열 히트펌프 시스템의 냉방 성능 평가 (Evaluation on Cooling Performance of Ground Source Heat Pump System Equipped with Steel-pipe Civil Structures)

  • 이석재;양정훈;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.14-22
    • /
    • 2023
  • Steel-pipe civil structures, including steel-pipe energy piles and cast-in-place piles (CIPs), utilize steel pipes as their primary reinforcements. These steel pipes facilitate the circulation of a working fluid through their annular crosssection, enabling heat exchange with the surrounding ground formation. In this study, the cooling performance of a ground source heat pump (GSHP) system that incorporated steel-pipe civil structures was investigated to assess their applicability. First of all, the thermal performance test was conducted with steel-pipe CIPs to evaluate the average heat exchange amount. Subsequently, a GSHP system was designed and implemented within an office container, considering the various types of steel-pipe civil structures. During the performance evaluation tests, parameters such as the coefficient of performance (COP) and entering water temperature (EWT) were closely monitored. The outcomes indicated an average COP of 3.74 for the GSHP system and the EWT remained relatively stable throughout the tests. Consequently, the GSPH system demonstrated its capability to consistently provide a sufficient heat source, even during periods of high cooling thermal demand, by utilzing the steel-pipe civil structures.

지반 조건을 고려한 최적강관두께의 결정 (The Determination of Optimal Steel Pipe Wall Thickness Considering Ground Condition)

  • 박재성;오병동;이호진
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.11-15
    • /
    • 2008
  • 대구경 상수도 관로는 제작 및 경제성 요인에 의해 주로 강관을 사용해 오고 있다. 상수도시설기준(건교부, 1992)에 강관두께를 결정하는 기준을 제시하고 있다. 그러나, 이 기준에는 강관 두께를 결정하는 체계적인 기준이 없다. 그래서, 매설관로에는 적용이 부적합한 Stewart 공식을 적용하여 강관두께를 결정해 왔다. 개정된 상수도시설기준(환경부, 1997) 에 부합되도록 지반여건과 각종응력을 고려하여 강관두께를 산정하였다. 그 결과를 기존의 방법에 의해 산정된 결과와 비교 검토한 후 최적 강관두께를 결정하는 방법을 제시하였다.

  • PDF

PE 피복형 파형강관의 플랜지 이음부 설계에 관한 연구 (A Study on Flange Coupling Design of Polyethylene Corrugated Steel Pipe)

  • 김태규;이호영;양상민
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.403-408
    • /
    • 2007
  • The concrete pipe(Hume, PC) and polyethylene(PE) pipe are usually used for dram pipe in local market. Hume pipe, however, is heavy and needs the high cost of construction and PC pipe has a disadvantage to easily occur the deformation by the outside pressure even though it is light and constructible. The corrugated steel pipe coated with polyethylene is used increasedly because it is durable, constructible and economical. However, it is not used for sewage or waste water because it is hard to guarantee the watertight property on the coupling part. In this study, we studied on the flange coupling and the method of its construction to guarantee the watertight property and easy to use. If the developed flange coupling and method are used on a construction field, the economical property, constructible property and structural safety can be guaranteed.

Corrosion Resistance of Zn and Cu Coated Steel Pipes as a Substitute for Cu Pipe in an Air Conditioner System

  • Shin, Jae-Gyeong;Park, Chan-Jin;Hong, Sung-Kil
    • Corrosion Science and Technology
    • /
    • 제8권1호
    • /
    • pp.40-43
    • /
    • 2009
  • We investigated the corrosion resistance of Zn and Cu coated steel pipes as a substitute for Cu pipe in an air-conditioner system. In addition, the galvanic corrosion tendency between two dissimilar metal parts was studied. The corrosion resistance of the Cu electroplated steel was similar to that of Cu, while the corrosion rate of the Zn electro- galvanized and the galvalume (Zn-55 % Al) coated steels was much higher and not suitable for Cu substitute in artificial sea water and acidic rain environments. Furthermore, the galvanic difference between Cu electroplated steel and Cu was so small that the Cu coated steel pipe can be used as a substitute for Cu pipe in an air-conditioner system.