• 제목/요약/키워드: Steam Generator Tube

검색결과 420건 처리시간 0.031초

Flow Characteristics Analysis for the Chemical Decontamination of the Kori-1 Nuclear Power Plant

  • Cho, Seo-Yeon;Kim, ByongSup;Bang, Youngsuk;Kim, KeonYeop
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.51-58
    • /
    • 2021
  • Chemical decontamination of primary systems in a nuclear power plant (NPP) prior to commencing the main decommissioning activities is required to reduce radiation exposure during its process. The entire process is repeated until the desired decontamination factor is obtained. To achieve improved decontamination factors over a shorter time with fewer cycles, the appropriate flow characteristics are required. In addition, to prepare an operating procedure that is adaptable to various conditions and situations, the transient analysis results would be required for operator action and system impact assessment. In this study, the flow characteristics in the steady-state and transient conditions for the chemical decontamination operations of the Kori-1 NPP were analyzed and compared via the MARS-KS code simulation. Loss of residual heat removal (RHR) and steam generator tube rupture (SGTR) simulations were conducted for the postulated abnormal events. Loss of RHR results showed the reactor coolant system (RCS) temperature increase, which can damage the reactor coolant pump (RCP)s by its cavitation. The SGTR results indicated a void formation in the RCS interior by the decrease in pressurizer (PZR) pressure, which can cause surface exposure and tripping of the RCPs unless proper actions are taken before the required pressure limit is achieved.

3차원 관결함에 대한 와전류탐상의 유한요소해석 (Finite Element Analysis of Eddy Current Testing for Tubes with 3-Dimensional Defects)

  • 이향범;원성연;신영길
    • 비파괴검사학회지
    • /
    • 제20권3호
    • /
    • pp.191-199
    • /
    • 2000
  • 본 논문에서는 3차원 형태의 결함을 가진 관에 대한 와전류탐상의 유한요소 수치해석에 대하여 연구하였다. 3차원 와전류탐상 문제를 기술할 수 있는 전자기 수치해석기법으로 3차원 유한요소법을 사용하였다. 맥스웰방정식으로부터 지배방정식을 구하고, 갤러킨 가중잔차법을 이용하여 유한요소정식화를 수행하였다. 해석대상으로는 INCONEL 600 증기발생기 전열관을 사용하였으며, 관의 내부 및 외부에 존재하는 결함을 모델링하여 수치해석을 수행하고, 임피던스로 표현되는 와전류탐상 신호를 계산하였다. 결함 시험편에 존재하는 결함에 대하여 본 논문에서 계산된 결과와 실험결과를 비교하였으며, 잘 일치하는 결과를 얻어 본 논문에서 제안된 수치해석 방법의 타당성을 검증하였다. 이를 바탕으로 결함의 깊이 변화(38%, 58%, 75%) 및 원주방향으로의 결함각도 변화$90^{\circ},\;180^{\circ},\;270^{\circ},\;360^{\circ}$)에 따른 탐상 신호를 계산하여 결함의 크기변화에 따른 신호의 변화특성을 살펴보았다.

  • PDF

소듐 시험루프 내 소듐대 공기 열교환기의 고온 설계 (High-Temperature Design of Sodium-to-Air Heat Exchanger in Sodium Test Loop)

  • 이형연;어재혁;이용범
    • 대한기계학회논문집A
    • /
    • 제37권5호
    • /
    • pp.665-671
    • /
    • 2013
  • 제 4 세대 소듐냉각 고속로에는 중간열교환기(IHX), 붕괴열제거 열교환기(DHX), 공기 열교환기(AHX), 핀형 소듐-공기 열교환기(FHX) 및 증기발생기(SG)를 포함한 다양한 열교환기들이 설치된다. 본 연구에서는 STELLA-1 시험루프에 설치된 소듐-공기 열교환기인 AHX 와 SELFA 시험루프에 설치될 핀형(finned) 소듐-공기 열교환기인 FHX 등 2 기의 열교환기 설계에 대해 3D 상세 유한요소해석을 수행하고, 동 결과에 기초하여 고온설계 기술기준을 따라 크리프-피로 손상평가를 수행하였다. 손상 평가결과 AHX와 FHX는 의도하는 크리프 피로 손상 하중 하에서 구조 건전성을 유지하는 것으로 확인되었다.

증기발생기 전열관의 투자율 변화신호 분리를 위한 신형 탐촉자 개발 (Development of New ECT Probe Separating the Permebility Variation Signal in the SG Tube)

  • 박덕근;유권상;이정기;손대락
    • 비파괴검사학회지
    • /
    • 제28권1호
    • /
    • pp.9-15
    • /
    • 2008
  • 증기발생기 전열관에 생성되는 투자율변화에 의해 야기되는 신호왜곡 문제를 해결하기 위한 새로운 탐촉자를 개발하였다. 고리 1 호기 폐전열관에 생성된 자성상을 분리하여 자기이력곡선을 측정하였으며, 자성상이 생성되는 원인을 규명하기 위하여 고온 인장 시험을 수행하였다. 전산모사를 이용하여 탐촉자의 자정상 탐지조건을 결정하였으며, 디지털 신호전송을 위하여 신호처리용 전자회로를 소형화하여 탐촉자 속에 삽입하였다. 본 연구에서 개발된 신형 탐촉자를 이용하여 PVC 신호와 니켈 슬리빙 부위의 결함을 측정하였다. 신형 탐촉자는 보빈 탐촉자와 같이 고속으로 결함을 측정 할 수 있으며, 증기발생기 전열관의 탐상속도와 결함 탐지의 신뢰성을 증진시킬 수 있다.

접촉한 두 평면과 균열한 틈새에서의 유동마찰계수 비교 (Comparison of the Friction-Loss Coefficient for the Gap of Two Contact Surfaces and a Crack)

  • 남호윤;최병해;김종범;이용범
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1075-1081
    • /
    • 2011
  • 이중벽관 증기발생기에서 전열관의 내관과 외관 사이의 틈새에 채워진 헬륨가스의 압력변동으로 전열관의 파손을 감지하는 방법이 개발되고 있다. 이 현상을 모사하기 위해 압력으로 밀착된 두 평판사이의 미세한 틈새에서의 누설률을 측정하여 실험식을 개발하였다. 이 실험식에서는 틈새의 간격과 유동마찰계수가 표면조도에 의해 상호 결합된 형태로 기술되는데, 간단한 평판접촉 모델을 사용하여 유동마찰계수 식을 분리하였다. 이 실험식과 균열에서의 누설률 예측에 사용되고 있는 기존의 유동마찰계수 관련 실험식들을 상호 비교하였다. 레이놀즈 수의 적용범위가 상이함에도 불구하고 개발한 실험식이 0.1~0.35 에서는 레이놀즈 수가 높은 경우에 적용되는 실험식들과 유사한 값을 보였다.

수치해석을 이용한 평균 양방향 유동 튜브 유량계의 파울링 환경 적용성 연구 (Numerical Study of the Averaging BDFT(bidirectional flow tube) Flow Meter on the Applicability in the Fouling Condition)

  • 박종필;정지환;강경호;백원필;윤병조
    • 한국유체기계학회 논문집
    • /
    • 제16권4호
    • /
    • pp.35-43
    • /
    • 2013
  • Most of the nuclear power plants(NPPs) adopts pressure difference type flow meters such as venturi and orifice meters for the measurement of feedwater flow rates to calculate reactor thermal power. However, corrosion products in the feedwater deposits on the flow meter by fouling as operating time goes. These effects lead to severe errors in the flow indication and then determination of reactor thermal power. The averaging BDFT, which has developed by Yun et al., has a potentiality to minimize this problem thanks to its inherent measurement principle. Therefore, it is expected that the averaging BDFT can replace the venturi meter for the feedwater pipe of steam generator of NPPs. The present work compares the amplification factor, K, based on CFD calculation against the K obtained from experiments in order to confirm whether a commercial CFD code can be applicable to the evaluation of characteristic for the averaging BDFT. In addition to this, the simulations to take into account of fouling effect are also carried out by rough wall option. The results show that the averaging BDFT is a promising flow meter for the accurate measurement of flow rates in the fouling condition of the NPPs.

COLLAPSE PRESSURE ESTIMATES AND THE APPLICATION OF A PARTIAL SAFETY FACTOR TO CYLINDERS SUBJECTED TO EXTERNAL PRESSURE

  • Yoo, Yeon-Sik;Huh, Nam-Su;Choi, Suhn;Kim, Tae-Wan;Kim, Jong-In
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.450-459
    • /
    • 2010
  • The present paper investigates the collapse pressure of cylinders with intermediate thickness subjected to external pressure based on detailed elastic-plastic finite element (FE) analyses. The effect of the initial ovality of the tube on the collapse pressure was explicitly considered in the FE analyses. Based on the present FE results, the analytical yield locus, considering the interaction between the plastic collapse and local instability due to initial ovality, was also proposed. The collapse pressure values based on the proposed yield locus agree well with the present FE results; thus, the validity of the proposed yield locus for the thickness range of interest was verified. Moreover, the partial safety factor concept based on the structural reliability theory was also applied to the proposed collapse pressure estimation model, and, thus, the priority of importance of respective parameter constituting for the collapse of cylinders under external pressure was estimated in this study. From the application of the partial safety factor concept, the yield strength was concluded to be the most sensitive, and the initial ovality of tube was not so effective in the proposed collapse pressure estimation model. The present deterministic and probabilistic results are expected to be utilized in the design and maintenance of cylinders subjected to external pressure with initial ovality, such as the once-through type steam generator.

A REVIEW ON THE ODSCC OF STEAM GENERATOR TUBES IN KOREAN NPPS

  • Chung, Hansub;Kim, Hong-Deok;Oh, Seungjin;Boo, Myung Hwan;Na, Kyung-Hwan;Yun, Eunsup;Kang, Yong-Seok;Kim, Wang-Bae;Lee, Jae Gon;Kim, Dong-Jin;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.513-522
    • /
    • 2013
  • The ODSCC detected in the TSP position of Ulchin 3&4 SGs are typical ODSCC of Alloy 600MA tubes. The causative chemical environment is formed by concentration of impurities inside the occluded region formed by the tube surface, egg crate strips, and sludge deposit there. Most cracks are detected at or near the line contacts between the tube surface and the egg crate strips. The region of dense crack population, as defined as between $4^{th}$ and $9^{th}$ TSPs, and near the center of hot leg hemisphere plane, coincided well with the region of preferential sludge deposition as defined by thermal hydraulics calculation using SGAP computer code. The cracks developed homogeneously in a wide range of SGs, so that the number of cracks detected each outage increased very rapidly since the first detection in the $8^{th}$ refueling outage. The root cause assessment focused on investigation of the difference in microstructure and manufacturing residual stress in order to reveal the cause of different susceptibilities to ODSCC among identical six units. The manufacturing residual stress as measured by XRD on OD surface and by split tube method indicated that the high residual stress of Alloy 600MA tube played a critical role in developing ODSCC. The level of residual stress showed substantial variations among the six units depending on details of straightening and OD grinding processes. Youngwang 3&4 tubes are less susceptible to ODSCC than U3 and U4 tubes because semi-continuous coarse chromium carbides are formed along the grain boundary of Y3&4 tubes, while there are finer less continuous chromium carbides in U3 and U4. The different carbide morphology is caused by the difference in cooling rate after mill anneal. There is a possibility that high chromium content in the Y3&4 tubes, still within the allowable range of Alloy 600, has made some contribution to the improved resistance to ODSCC. It is anticipated that ODSCC in Y5&6 SGs will be retarded more considerably than U3 SGs since the manufacturing residual stress in Y5&6 tubes is substantially lower than in U3 tubes, while the microstructure is similar with each other.

모사 와전류 탐상신호를 이용한 비대칭 단면을 갖는 축대칭 결함의 형상분류 (Classification of Axis-symmetric Flaws with Non-Symmetric Cross-Sections using Simulated Eddy Current Testing Signals)

  • 송성진;김창환;신영길;이향범;박윤원;임창재
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.510-517
    • /
    • 2001
  • 본 연구는 와전류 형상인식 기법을 증기발생기 세관의 보다 실제적인 결함 평가 문제에 적용하기 위한 목적으로 시도되었다. 이를 위해 증기발생기 세관에 발생하는 실제적인 결함을 보다 사실적으로 모사하는 다섯 가지 형태의 외벽 결함을 선택하고, 이들 결함의 크기 인자와 시험주파수를 변화시켜 가면서, 유한요소 수치해석 프로그램을 이용하여 이론적인 결함신호를 생성하였다. 그리고, 이들 결함신호의 분석을 효율적으로 수행하기 위한 도구로서, '와전류 특징추출 프로그램', '와전류 특징분석 프로그램', 그리고 'PNN 결함분류 프로그램'을 자체적으로 개발하였다. 비대칭 단면을 갖는 결함의 신호는 교점이 원점으로부터 이격되는 현상이 관찰되었는데, 이러한 특성을 반영하는 특징을 추가하여 총 18개의 특징을 시험주파수 별로 정의하였다. 이 특징들을 이용하여 결함을 분류하는 확률신경회로망을 구성하고 결함 분류를 수행한 결과, 결함단면의 대칭성 여부를 결정하는 문제에서는 비교적 높은 정확도를 얻었으나, 결함선단의 첨도를 판단하는 문제에서는 낮은 정확도를 얻었다.

  • PDF

Expectation Maximization (EM)과 Least Mean Square(LMS) algorithm을 이용하여 초음파 비파괴검사 신호의 분류를 하기 위한 새로운 접근법 (A novel approach to the classification of ultrasonic NDE signals using the Expectation Maximization(EM) and Least Mean Square(LMS) algorithms)

  • Daewon Kim
    • 융합신호처리학회논문지
    • /
    • 제4권1호
    • /
    • pp.15-26
    • /
    • 2003
  • 초음파 검사 방법은 여러 가지 물질들의 흠집이나 틈새, 그리고 티끌 등을 감지해내는데 널리 쓰이고 있다. 그 중 초음파 신호를 분석하는 절차는 전체의 신호처리 과정에서 아주 중요한 역할을 담당하고 있다. 많은 초음파 신호처리와 신호분류의 방법들이 제기 되었는데 그 중 가장 널리 쓰이는 방법은 신호들의 특징 공간상에서 그 특정의 성분들을 추출해내고 그 후 신경망 네트웍을 통한 분류 방법을 이용하여 초음파 신호들을 구별해 내는 방법이다. 이 논문은 기존의 신호 분류 체계와는 다른 대체 신호 분류법을 제시하고 있는데 이것은 최소 평균 제곱 (LMS) 알고리즘을 이용하여 핵 전력 발전소에서 쓰이는 증기 발생기 튜브로부터 감지되어진 초음파 비파괴 검사 신호 (ultrasonic nondestructive evaluation signal) 을 분류해내는데 쓰일 수가 있다 이 초음파 비파괴 검사 신호는 튜브내의 흠집이나 틈새로부터 감지되어진 신호일수도 있고 또는 튜브내의 침전물에 의해서 발생된 신호일 수도 있는데 이 두가지 신호는 매우 유사하기 때문에 반드시 분류를 해내어 침전물에 의한 신호일 경우는 무방하지만 흠집이나 갈라진 틈새에서 나오는 신호일 경우는 더 이상의 오염이나 사고 등을 방지하기 위해 수리 또는 교체 등의 후속 조치로 이어져야 한다. 이러한 절차를 밟기 위하여 증기 발생기 튜브의 내부에서의 초음파 센서로부터 증기 발생기 튜브 사이의 거리를 측정하는데 모델링 기법에 기반한 deconvolution 방법이 제시되었고 여기서 나온 결과가 정리, 분석되었다 이 방법은 space alternating generalized expectation maximization (SAGE) 알고리즘을 이차원 미분 파라미터인 Hessian의 사용으로 인하여 수렴 속도가 빠른 Newton-Raphson 알고리즘과 함께 병행 사용하여 초음파 신호의 초점 도달 시간과 그 크기를 측정하여 초점 도달 거리에 따라 두 종류의 신호를 분류, 차별화 하는 기법이다. 이 알고리즘을 이용한 접근법으로 얻어진 결과가 흠집이나 틈새로부터 나온 신호일 경우와 퇴적물에 의해 나온 신호일 경우로 정리, 분류되었고 적절한 분류 효과를 보인 결과가 이 논문에 제시되었다.

  • PDF