• Title/Summary/Keyword: Steady-state Response

Search Result 656, Processing Time 0.031 seconds

Novel Current Controlled PWM-VSC Converter Using Current Error Vector Control (전류오차 백터 제어방식에 의한 새로운 형태의 전류 제어 PWM 전압형 정류기)

  • 박민호;최재호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.4
    • /
    • pp.261-268
    • /
    • 1989
  • A novel current controlled PWM voltage source type converter and control strategy is proposed that is able to draw nearly sinusoidal current at unity power factor from three phase power lines. Current error vector control scheme is used which has two operating states : low harmonic current content state and quick current response state. The state is changed according to the current error to optimize the steady state and transient state performances. To regulate the dc oupput voltage, the magnitude of the reference current is determined by a controller dc voltage error. The ac input power factor can be controlled with unity, and even leading or lagging by adjusting the relative position of the reference current with respect to the supply voltage.

  • PDF

Control Characteristics of Current Controlled PWM Using Vector Control in VSI-IM Drive System (VSI-IM 구동 시스템에 벡터제어를 이용한 전류제어 PWM 방식의 제어특성)

  • Dong Hwa Chung
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.12
    • /
    • pp.38-50
    • /
    • 1991
  • A current-controlled scheme of pulse width modulation voltage source inverter (PWM VSI) has attracted considerable attention due to its fast response with current limit and especially suitable for potentially high performance applications such as AC motor drives and UPS systems. These features yield near-sinusoidal currents in the load with reduced current peaks, lower inverter switching frequency and reduce inverter and load stresses. A high performance current-controlled inverter must have a quick response in transient state and low harmonic current in steady state. This paper compares and shows the controlled-characteristics with hysteresis controller(HC), ramp comparison controller(RCC) and predictive controller(PC) of PWM inverter to control actual current of VSI-IM.

  • PDF

A study on the compensator design of the quasi-resonant SMPS (유사공진형 SMPS의 보상기 설계에 관한 연구)

  • Lim, I.S.;Huh, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.720-725
    • /
    • 1991
  • In this thesis, the lead-lag compensator is designed to improve output characteristics of flyback zero voltage switching quasi-resonant converters. The switch and the diode are assumed ideally. And the SMPS is modelled by state equations with four operation modes. And the model for controller design is also achived by using a state space averaging method, which is continuous time average of state variables every period. The lag, the lead and the lead-lag compensator is designed the SMPS respectively. The time domain analysis and the frequency domain analysis are done for each compensated circuit. It is possible increasing the phase margin and improving the transient response by the compensators. The phase lag compensator has small overshoot comparatively. But the bandwidth is narrower than the others, so it has longest settling time. For the phase lead compensator, the response come to steady-state within short period. But the overshoot is the largest due to its large peak gain. Finally, the phase lead-lag compensator has medium characteristics in the overshoot and the settling time.

  • PDF

Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System (스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.2
    • /
    • pp.361-370
    • /
    • 2024
  • In this paper, a method was studied for applying a series resonant type fault current limiter that can be manufactured at low cost to the smart grid distribution system. First, the impact of the harmonic components of the short-circuit fault current injected into the series resonance circuit of the fault current limiter on the peak value of the transient response was analyzed, and a methodology for determining the steady-state response was studied using percent impedance-based fault current computation method. Next, the effectiveness of the method was verified by applying it to a test distribution line. The test distribution system using the designed current limiter was modeled using EMTP_RV, and a three-phase short-circuit fault was simulated. In the fault simulation results, it was confirmed that the steady-state response of the fault current accurately followed the design target value after applying the fault current limiter. In addition, by comparing the fault current waveform before and after applying the fault current limiter, it was confirmed that the fault current was greatly suppressed, confirming the effect of applying the series resonance type current limiter to the distribution system.

Comparison of Aerobic Fixed-film Process Response to Quantitative and Hydraulic Shock for the Same Increases in Mass Loading (호기성 고정생물막반응기에서 동일 질량부하의 수리학적 및 농도충격부하시 반응의 비교)

  • Ahn, Mee-Kyung;Lee, Kyu-Hoon
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.285-296
    • /
    • 1994
  • The objective of this study was to examine and compare to transient response to quantitative and hydraulic shocks which produce equal changes in mass rate of organic feed in aerobic fixed-film process. The general experimental approach was to operate the system at several growth rates under steady-state(pre-shock) conditions, then to apply step changes during day 3 in dilution rate(hydraulic shock) , or feed concentration(Quantitative shock) at the same organic mass loading rate. Performance was assessed in both the transient state and the new steady-state (post- shock). Shock load of different type did not produced equivalent disruptions of effluent quality for equal increases in mass loading rate. Based on effluent concentrations, a hydraulic and a Quantitative shock at the same mass loading caused equal increase in total effluent COD, but the increase was primarily a result of suspended solids the hydraulic shock and COD in the quantitative shock. The time which effluent COD came to peak values were about 32~48 hours at the low organic loads and 52 ~ 72 hours at the high organic loads, respectively A quantitative shock produced a much greater increase in effluent COD than did a hydraulic shock at the same mass loading. Mean and peak values of effluent concentration weve increased in 2.8~4.2 times at low organic loading rate, 5.2~6.6 times at the high organic loading rate, respectively. Key words : Aerobic fixed-film reactor, Quantitative shock, hydraulic shock, mass loading rate.

  • PDF

Fuzzy Control for High Performance of Induction Motor Using Electric Vehicles (전기자동차용 유도전동기의 고성능 제어를 위한 퍼지제어)

  • 정동화
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.52-61
    • /
    • 1999
  • This paper proposes the application of fuzzy control for high performance control of induction motor using electric vehicles. A fuzzy controller converts a set of liguistic rules based on expert knowledge into a automatic control strategy. Such controllers have often been found superior to conventional controllers especially when information being processed is inexact and uncertain. A system with fast torque response is very beneficial in applications where direct self control (DSC) is highly desirable. The response of DSC is slower during startup and during change in command torque. Fuzzy control is used for implementation of DSC to improve its slow response. Simulation implementation of the fuzzy logic controller was carried out to verify the behavior of the controller. The simulation results with fuzzy control are compared with those of the conventional DSC. The starting flux and torque response and the responses to the step changes in command torque with fuzzy implementation show a considerable improvement over the conventional control. The steady state responses in both the cases are the same.

  • PDF

A Study on the Forced Vibration Responses of Various Buried Pipelines (각종 매설관의 강제진동거동에 관한 연구)

  • Jeong, Jin-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1334-1339
    • /
    • 2006
  • Dynamic response of buried pipelines both in the axial and the transverse directions on concrete pipe and steel pipe, FRP pipe were investigated through a forced vibration analysis. The dynamic behavior of the buried pipelines for the forced vibration is found to exhibit two different forms, a transient response and a steady state response, depending on the time before and after the transfer of a seismic wave on the end of the buried pipeline. The former is identified by a slight change in its behavior before the sinusoidal-shaped seismic wave travels along the whole length of the pipeline whereas the latter by the complete form of a sinusoidal wave when the wave travels throughout the pipeline. The transient response becomes insignificant as the wave speed increases. From the results of the dynamic responses at the many points of the pipeline, we have found that the responses appeared to be dependent critically on the boundary end conditions. Such effects are found to be most prominent especially for the maximum values of the displacement and the strain and its position.

  • PDF

Improved Response of Time-Delay System with Integrator (적분기를 갖는 시간지연 시스템의 응답특성 개선)

  • Lee, Suk-Won;Yang, Seung-Hyun;Lee, Kyu-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.930-932
    • /
    • 1999
  • Recently a new modified Smith predictor is proposed for a time-delay system with an integrator. It is shown that the approximate model yields the zero-steady state error and the disturbance compensator improved the transient response. But in case of mismatch between the plant's time-delay and model's time-delay, the overall response is not satisfactory. In this paper, it is proposed that the proper pole is added to the new modified smith predictor to improve the overall response.

  • PDF

A design on robust integral-type optimal model following servo system (강인한 적분형 최적 모델 추종형 서보계의 구성에 관한 연구)

  • 황창선;김정택;이양우;최일섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.1024-1027
    • /
    • 1992
  • This paper deals with design method of the model following servo system in which optimal regulator probelm is used to design the controllers that make the step/ramp response of the plant be keptclose to a specified ideal step/ramp response of the model. The characteristics of this system is robust in the presence of the specified disturbances or the partameter perturbations of the plant. Especially, by direct feedforward compensator from the reference input the steady state offset of plant output response is excluded and the transient response is improved. Examples are give and the results of the design of the model follwing servo systems are verified by the computer simulation.

  • PDF

Transient Response Analysis of DC Voltage Regulating System with Amplidyne Saturation Effect (Amplidyne의 포화현상을 고려한 직류정전압계통의 과도응답 해석)

  • 이승원;김남호
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.55-58
    • /
    • 1977
  • This paper deals with the transient analysis of an amplidyne dc voltage regulating system under the following conditions: (1) assuming all the components of the system to be linear, (2) considering the effect of amplidyne saturation. The mathematical technique employed is state variables method. The calculated response curves are compared with the experimental results obtained on a practical system. The main results can be summerized as follows: 1) The effect of amplidyne saturation on the transient response of a dc voltage regulating system is to reduce the overshoot and setting time. 2) With the increase in level of the step reference voltage, the system response becomes apesiodic. 3) The steady output voltage is reduced appreciably compared to the linear case.

  • PDF