• Title/Summary/Keyword: Station Influence Area

Search Result 139, Processing Time 0.027 seconds

A Study on the Damage of Flame caused by the Vapor Cloud Explosion in LPG Filling Station (LPG충전소에서 증기운폭발에 의한 화염의 피해에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.53-60
    • /
    • 2010
  • LPG(Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, LPG demand is growing rapidly as an environmentally friendly energy source and its gas station is also increasing every year. Consequently, this study tries to find out the influence of flame caused by the VCE(Vapor Cloud Explosion) in filling station on the adjacent combustibles and people by simulating relevant quantity of TNT. In addition, the damage estimation was conducted by using API regulations. If the scale of the radiation heat is known by calculating the distance of flame influence from the explosion site, the damage from the site can be easily estimated. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the probit analyze, the spot which is 30m away from the flame has 100% of the damage probability by the first-degree burn, 99.2% of the damage probability by the second-degree burn and 93.4% of the death probability by the fire.

The Intrinsic Safety Evaluation of Solar Photovoltaic Cell (태양전지셀의 본질안전 방폭성능 평가)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Si-Kuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.

Effect of relative stiffness on seismic response of subway station buried in layered soft soil foundation

  • Min-Zhe Xu;Zhen-Dong Cui;Li Yuan
    • Geomechanics and Engineering
    • /
    • v.36 no.2
    • /
    • pp.167-181
    • /
    • 2024
  • The soil-structure relative stiffness is a key factor affecting the seismic response of underground structures. It is of great significance to study the soil-structure relative stiffness for the soil-structure interaction and the seismic disaster reduction of subway stations. In this paper, the dynamic shear modulus ratio and damping ratio of an inhomogeneous soft soil site under different buried depths which were obtained by a one-dimensional equivalent linearization site response analysis were used as the input parameters in a 2D finite element model. A visco-elasto-plastic constitutive model based on the Mohr-Coulomb shear failure criterion combined with stiffness degradation was used to describe the plastic behavior of soil. The damage plasticity model was used to simulate the plastic behavior of concrete. The horizontal and vertical relative stiffness ratios of soil and structure were defined to study the influence of relative stiffness on the seismic response of subway stations in inhomogeneous soft soil. It is found that the compression damage to the middle columns of a subway station with a higher relative stiffness ratio is more serious while the tensile damage is slighter under the same earthquake motion. The relative stiffness has a significant influence on ground surface deformation, ground acceleration, and station structure deformation. However, the effect of the relative stiffness on the deformation of the bottom slab of the subway station is small. The research results can provide a reference for seismic fortification of subway stations in the soft soil area.

Fluctuating wind loads across gable-end buildings with planar and curved roofs

  • Ginger, J.D.
    • Wind and Structures
    • /
    • v.7 no.6
    • /
    • pp.359-372
    • /
    • 2004
  • Wind tunnel model studies were carried out to determine the wind load distribution on tributary areas near the gable-end of large, low-rise buildings with high pitch planar and curved roof shapes. Background pressure fluctuations on each tributary area are described by a series of uncorrelated modes given by the eigenvectors of the force covariance matrix. Analysis of eigenvalues shows that the dominant first mode contributes around 40% to the fluctuating pressures, and the eigenvector mode-shape generally follows the mean pressure distribution. The first mode contributes significantly to the fluctuating load effect, when its influence line is similar to the mode-shape. For such cases, the effective static pressure distribution closely follows the mean pressure distribution on the tributary area, and the quasi-static method would provide a good estimate of peak load effects.

An Analysis of the Impact of Subway Construction on Apartment Price in the Station Areas: Focusing on the Daegu Subway Line 3 (도시철도 건설과 역세권이 아파트가격에 미치는 영향 분석 - 대구도시철도 3호선 역세권 거리와 아파트 면적 구분을 중심으로 -)

  • Lee, Kyutai;Kim, Eunjee;Doh, Soogwan
    • Journal of the Korean Regional Science Association
    • /
    • v.32 no.1
    • /
    • pp.3-26
    • /
    • 2016
  • This study aims to examine the influence of the Daegu Subway Line 3 construction on apartment price fluctuation and to find the factors causing the apartment price fluctuation in the station area of the Daegu Subway Line 3. Empirical results of this study are as follows: first, the apartment price is more fluctuated or increased at the time of completion of subway construction than at the time of breaking ground; second, the opening of the Daegu Subway Line 3 has positive impact on apartment price nearby the station area of the Daegu Subway Line 3, especially apartment prices in the second station area (200-600m) are positively related to the opening of the Daegu Subway Line 3; third, medium-large size ($85-135m^2$) and large size (excess of $135m^2$) apartment are sensitively related to the apartment price fluctuation by the Daegu Subway Line 3 construction; and fourth, Buk-gu and Suseong-gu areas are the main beneficiaries. The results of this study suggest implications for tax and redistribution policies in the station areas.

Flux Footprint Climatology and Data Quality at Dasan Station in the Arctic (북극 다산기지에서의 플럭스 발자취 기후도와 플럭스 자료 품질)

  • Lee, Bang-Yong;Choi, Tae-Jin;Lee, Hee-Choon;Yoon, Young-Jun
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.4
    • /
    • pp.201-205
    • /
    • 2005
  • Turbulent fluxes of heat, water vapor, and CO2 have been measured since August, 2003 at Dasan Station (78o 55’ N, 11o50’E) in the Arctic. These data can allow us to better understand the interactions between the Polar ecosystems and the atmosphere together with those at King Sejong Station in the Antarctic. Due to the buildings and measurement platforms around the flux tower, it is required to evaluate how they influence measured flux data. By using one-year turbulence statistics data and footprint model, flux footprint climatology was analyzed together with data availability. The upwind distance of source area ranged from 150 to 300 m, where the buildings and measurement platforms existed. However, flow distortion due to them may be not a major factor to reduce the data availability significantly. Based on, the dominant wind direction of SW and footprint climatology, the location of flux tower is considered suitable for flux measurement.

  • PDF

Suitability Modelling for Potential Sites for Seoul's 2030 Youth-Housing Projects: Focusing on the 5th Policy Modification and the Youth's Demand (서울시 역세권 청년주택 사업 적지평가 모형: 5차 운영기준 개정과 청년수요의 반영을 중심으로)

  • Park, MinHo;Kim, MyoungHoon;Cheon, SangHyun
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.49-59
    • /
    • 2020
  • The Seoul's 2030 Youth-Housing is a policy to promote the development of private sector-built rental housing in a Station Influence Area (SIA). It is a representative policy to resolve a housing problem for the youth in Seoul. The Seoul Metropolitan Government has made continuous policy improvements to respond to earlier criticisms on the policy. In December 2018, the Seoul Metropolitan Government enlarged the possible spatial boundaries of the SIA that the private sector developer can carry out the housing development projects. This study attempts to assess the potential sites available in Seoul by considering the youth's demand. This study used the suitability modelling technique to evaluate the potential sites. In detail, we established three sub-models by reflecting rent, accessibility to living areas of the youth, and accessibility to living SOC for the youth's demand. According to the results, the Hanyang City Wall area, which was newly included by the recent policy revision, showed moderate scores to fit the housing projects, while some Gangbuk areas, which have high accessibility and relatively lower rents, showed the best scores appropriate for the projects. The age group of 20s preferred university districts, while the age group of 30s preferred to locate near Seoul's main office areas. We suggest that the Seoul metropolitan government develops better ways to guage and reflect the demand for differing youth groups and the demand by age groups.

The Influence of Rice Black-Streaked Dwarf Virus on the Rice Yield and Its Components (벼 검은줄무늬오갈병이 수량과 수량구성요소에 미치는 영향)

  • Kim D.K.;Park R.K.;Jung Y.T.;Jin Y.D.
    • Korean journal of applied entomology
    • /
    • v.22 no.3 s.56
    • /
    • pp.193-197
    • /
    • 1983
  • In 1981 Rice Black-Streaked Dwarf Virus (RBSDV) was severely occurred in Yeongnam area of Korea. The influence of RBSDV to rice plant was studied with two susceptible cultivars, Nagdongbyeo and Cheongcheongbyeo. The stunting rate was determined by the percentage of plant height of infected plants vs. healthy plants. When the rice plants were severely stunted by RBSDV, the yield components and yield were greatly reduced. The stunting of rice plants infected with RBSDV was caused mostly by the shortening of internodes in upper parts of the culm. The relationship between stunting rate of rice plants and yield was shown to have a negative exponential correlation. The regression equations of the relationship are experssed as follows: In Cheongcheongbyeo $Y=46.6lxe^{-0.0624_\chi}$, and in Nagdongbyeo $Y=54.82xe^{-0.067_\chi}$.

  • PDF

Influence Factors on User Satisfaction of Commercial Areas in Downtown -focused on commercial areas near Cheonan railway station and central bus terminal- (도심 상업지역 이용자 만족도에 미치는 영향요소 분석 -천안역과 종합버스터미널 주변 상업지역을 중심으로-)

  • Jeong, Jae-Jin;Kim, Sung-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5274-5280
    • /
    • 2013
  • The aim of this study is to analyze the general satisfaction of the commercial areas near Cheonan central bus terminal and the rail-station and to extract various environmental factors of the city center which give effect to the user satisfaction of commercial area. As the result of the analyses, the environmental factors of the city center make a difference between the commercial areas of Cheonan central bus terminal and of the station in the aspects of user satisfaction. The user satisfaction of the commercial areas is appeared highest in 'comfort of walking environments' and 'convenience of commerce business transaction' which were environmental factors of the city center. For reactivation of the commercial area near Cheonan rail-station are needed improvement of walking environments and relocation of facilities as complex mall and bank etc.

A Study on the Impact Scope from Hazardous Chemicals Leakage in Jeju Area - Focused on hydrogen fluoride - (제주지역 유해화학물질 누출사고 시 영향범위에 관한 연구 - 불화수소 중심으로 -)

  • Lim, Chaehyun;Doh, Sang Hyeun;Kim, Changyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.495-502
    • /
    • 2018
  • In this study, the AERMOD air diffusing model was used to estimate the range of influence of Hazardous chemicals (hydrogen fluoride) in case of small accidents in Jeju area. The impact scope were in the order of Seogwipo Fire Station, Dongbu Fire Station, Jeju Fire Station, and Seobu Fire Station. Seasonal orders were summer, spring, autumn and winter. The correlation between the meteorological factors shows a strong positive correlation with the wind speed of 0.998 and has a negative correlation with the temperature of -0.463. Through the linear regression analysis, we could estimate the equation of Impact scope = 13.922WS (Wind Speed) - 5.195 and the reliability ($R^2$) was as high as 0.995.