• Title/Summary/Keyword: Static pressure

Search Result 1,380, Processing Time 0.038 seconds

Influence of Trunk Stabilization Exercise upon the Lumbar Stabilization and Foot Pressure in Patients with Back Pain (체간 안정화 운동이 요통환자의 요부안정성과 족저압에 미치는 영향)

  • Lee, Woo-Jin;Park, Seol;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • Purpose: This study examined the effect of trunk stabilization exercise upon the lumbar stabilization and foot pressure on an unstable surface with back pain. Methods: The subjects of the study were 10 patients who showed the symptom of back pain with excessive lumbar curve. This study was 4 weeks, 30 minutes per session, three times a week for a total of 12 times as a result of exercise radiation imaging device and foot pressure analyzer. Results: The sacrohorizontal angle was statistically significant(p<0.05). Comparison of the difference between static right and left foot pressure ratio analysis was statistically significant(p<0.05). Dynamic right and left foot pressure comparisons for the difference was statistically significant in the analysis (p<0.05). Conclusion: Trunk stabilization exercise and the reduction of the excessive sacrohorizontal angle, and static and dynamic foot pressure imbalance reduced left and right.

Highly Sensitive Flexible Organic Field-Effect Transistor Pressure Sensors Using Microstructured Ferroelectric Gate Dielectrics

  • Kim, Do-Il;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.277.2-277.2
    • /
    • 2014
  • For next-generation electronic applications, human-machine interface devices have recently been demonstrated such as the wearable computer as well as the electronic skin (e-skin). For integration of those systems, it is essential to develop many kinds of components including displays, energy generators and sensors. In particular, flexible sensing devices to detect some stimuli like strain, pressure, light, temperature, gase and humidity have been investigated for last few decades. Among many condidates, a pressure sensing device based on organic field-effect transistors (OFETs) is one of interesting structure in flexible touch displays, bio-monitoring and e-skin because of their flexibility. In this study, we have investigated a flexible e-skin based on highly sensitive, pressure-responsive OFETs using microstructured ferroelectric gate dielectrics, which simulates both rapidly adapting (RA) and slowly adatping (SA) mechanoreceptors in human skin. In SA-type static pressure, furthermore, we also demonstrate that the FET array can detect thermal stimuli for thermoreception through decoupling of the input signals from simultaneously applied pressure. The microstructured highly crystalline poly(vinylidene fluoride-trifluoroethylene) possessing piezoelectric-pyroelectric properties in OFETs allowed monitoring RA- and SA-mode responses in dyanamic and static pressurizing conditions, which enables to apply the e-skin to bio-monitoring of human and robotics.

  • PDF

The Tense-Lax Question and Intraoral Air Pressure in English Stops

  • Kim, Dae-Won
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.113-130
    • /
    • 2002
  • Measurements were made of pressure rise time (PoRT), voice cessation time, flattened peak intraoral air pressure (Po), pressure static time (PoST), pressure-fall time and the duration of oral closure as four English speakers uttered isolated nonsense $V_{1}CV_{2}$ words containing /b/ and /p/ ($V_{1}=V_{2}$ and the V was /$\alpha$/), with stress on either $V_{1}orV_{2}$ alternately. The hypothesis tested was: The tense stop consonant. will be characterized either by a higher Po or a longer PoST, and/or by both against lax. Findings: (1) PoRT was significantly greater in /b/ than /p/, (2) the voiceless stop /p/ produced generally greater mean Po, averaged across five tokens, than its voiced counterpart /b/, but statistically insignificant, and (3) altogether, across stress, tokens and subjects, the difference in the calculated pressure static time (PoSTc), i.e., PoST + PoRT, between /p/ and /b/ was highly significant (p $\leq$ 0.003). Although further investigations remain to be taken, the results strongly supported the linguistic hypothesis of tense-lax distinction, with /b/ being lax and /p/ tense. Airflow resistance at the glottis and supraglottal air volume are assumed to be responsible for much of difference in PoRT between /p/ and /b/. The PoSTc reflecting, although indirectly, the respiratory efforts during the oral closure of a stop, was a convincing phonetic parameter of the consonantal tenseness based on respiratory efforts. The effects of stress on Po and PoSTc were inconsistent, and the shorter PoRT than consonantal constriction interval was always accompanied by Po and PoST.

  • PDF

Analysis of the Foot Indices Using Dynamic and Static Check of Postgraduate School Students in Yangsan (양산지역 대학원 일개 학년 학생을 대상으로 동적검사 및 정적검사를 통한 족부지표 분석)

  • Tcheun, Kyoung-Jae;Park, Dal-A;Shin, Byung-Cheul;Hwang, Eui-Hyoung;Heo, In;Kim, Byung-Jun;Lim, Kyeong-Tae;Heo, Kwang-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.11 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • Objectives : To evaluate the foot indices using dynamic and static checking on healthy adult people. Methods : Foot indices analysis was performed for 46 students. Static checking practiced for Foot Pressure(FP) and Toe Pressure Difference(TPD) and dynamic checking was used for Vertical Axis Angle(VAA). Results : On gender, there was generally no statical significant difference, except RFP(Right Foot Pressure). The RFP of male was bigger than that of female. On age, in addition, there was similar tendency, only RFP had a positive correlation (r=0.35, p<0.05). Comparing foot indices on right and left, we found TPD and VAA had a tendency of pronation on left, but FP had a opposite tendency. On consistency of each foot index, discrepancy between TPD and VAA (39.47%) was lesser than combination of the others. Conclusions : According to foot indices among 46 healthy student, we found out that there is partially correlation between dynamic and static checking. We hope that the data we found will contribute to standardization of podiatry indices which provide medical guidance for cure of foot disease, supporting further podiatry research.

  • PDF

Effects of Consecutive whole Body Vibration Exercise using Heel Raise Posture on Neuromuscular Response during Single-leg Stance (뒤꿈치 들기 자세를 이용한 전신진동 운동이 외발서기 시 근신경 반응에 미치는 영향)

  • Kim, Dae Dong;Lee, Myeounggon;Youm, Changhong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.104-112
    • /
    • 2021
  • Objective: This study aimed to analyze the effects of consecutive whole body vibration through heel raise posture on the center of pressure and electromyography of anterior tibial muscle, lateral gastrocnemius and soleus muscles during single-leg stance. Method: The subjects of this study included 30 healthy males in their 20's, with the following inclusion criteria: no history of orthopaedic medical history, no participation in regular exercises, no history of whole body vibration exercise, and right leg being the dominant leg. The experimental procedure involved pretreatment measurement of eye open single-leg stance, application of whole body vibration for 30 seconds, post-treatment measurement (3 measurements in total). Static and dynamic movements have been measured over 2 separate experiments, with 72 hours gap between the experiments. Static movement involved maintaining single-leg heel raise posture for 30 seconds while applying whole body vibration, and dynamic movement involved heel raise (15 repetitions over 30 seconds) while applying whole body vibration. The strength of applied whole body vibration was 35 Hz frequency and 2~4 mm amplitude. Results: As the single-leg posture after static heel raise posture, mediolateral velocity of the center of pressure at post 2 and post 3 were significantly reduced compared to the pre-treatment measurement. In addition, the percentage for reference voluntary contraction in anterior tibial muscle and soleus and median frequency at anterior tibial muscle and lateral gastrocnemius muscle at post 3 were significantly decreased compared to the pre-treatment value. As the single-leg posture after dynamic heel raise posture, the mediolateral 95% edge frequency of the center of pressure and median frequency at anterior tibial muscle, lateral gastrocnemius muscle, and soleus muscle at post 3 were significantly reduced compared to the pre-treatment value. Conclusion: Acute whole body vibration via static and dynamic heel raise posture have positive effect on mediolateral posture control during single-leg stance.

Fiber optic pressure sensor (광섬유 압력센서)

  • 이기완;배준형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.640-643
    • /
    • 1996
  • In this paper, a sensitivity of the fiber optic pressure sensor in water is demonstrated. A single mode optical fiber Mach-Zehnder interferometer used to detect the change in optical path length produced by the change of fiber optic strain in water. The sensitivity with this system measured 100.mu.psia through an experiment in the static response.

  • PDF

Immediate Effects of Myofascial Release Using Vibration Foam Rolling Methods on Hamstrings Range of Motion, Flexibility, Pressure Pain Thresholds and Dynamic Balance

  • Kim, Ho;Shin, Wonseob
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2042-2051
    • /
    • 2020
  • Background: Many trials have been conducted the methods and types of intervention of form rollers, but no research has been done yet that mixes the methods and types of intervention. Objectives: To analyze the effects of myofascial release on the improvement of range of motion (ROM), flexibility, pain pressure threshold, and balance. Design: Randomized controlled trial. Methods: All subjects measured ROM, flexibility, pressure pain threshold, and dynamic balance by pre-test. After pre-test, subjects were randomized that static-vibration foam rolling group (n=12), dynamic-vibration foam rolling group (n=12), general foam rolling group (n=12). For the intervention, 3 sets of 90 seconds were applied to each group, and rest time was set to 60 seconds between sets. In the post-test and follow-up test after 10 minutes, all three groups were measured the ROM, flexibility, pressure pain threshold, and dynamic balance. Results: The results of comparing ROM, flexibility, pressure pain thresholds, dynamic balance ability appeared higher significant difference in the pre-post-10 minutes follow up test in comparison between time in the intragroup (P<.001). As a result of comparing the change of pre-post-10 minutes follow up, static vibration foam rolling showed higher significant difference compared to control groups (P<.001). Conclusion: Through this study, when foam rolling is applied within the same intervention time, static foam rolling can be expected to have a better effect than the existing dynamic foam rolling as well as vibration foam roller can expect better effect than general foam rolling.

Mach 5 Performance Tests of Scramjet Engine Intake Using Free-jet Type Ground Propulsion Test Facility (자유제트형 지상추진 시험설비를 사용한 스크램제트 엔진 흡입구의 마하 5 성능시험)

  • Lee, Yang Ji;Yang, Inyoung;Lee, Kyung Jae;Oh, Jung Hwan;Choi, Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.4
    • /
    • pp.10-20
    • /
    • 2022
  • The performance analysis test of the scramjet engine intake was conducted under the Mach 5 condition of the scramjet engine test facility, a free-jet ground test facility of the Korea Aerospace Research Institute. A pitot/static pressure rake installed at the rear of the isolator was designed and manufactured to measure the total pressure recovery rate and mass capture ratio, which are typical performance factors of the scramjet engine intake. The effect of the rake mounted at the rear of the isolator on the intake, the performance analysis measured by the rake, and the change in wall static pressure distribution according to the angle of attack were performed. Finally, the point at which the intake unstart occurred was confirmed by using the rear back pressure adjusting device, which simulates pressure rise in the combustor, and the results are summarized in this paper.

Experimental Study on Supersonic Combustor using Inclined Fuel Injection with the Cavity, Part 2 : Pressure Measurement (공동 상류 경사 분사를 이용한 초음속 연소기의 실험적 연구, Part 2 : 압력 측정)

  • Jeong, Eun-Ju;Jeung, In-Seuck;O'Byrne, Sean;Houwing, A.F.P
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 2007
  • The supersonic combustion experiments are carried out using T3 free-piston shock tunnel. Different shock tube fill pressures have various inflow conditions. $15^{\circ}$ inclined hydrogen fuel injection is located before the cavity. Oblique shock is generated at the trailing edge of the cavity and reflects off the top and bottom wall. For non-reacting flow, static pressures in low equivalence ratio are similar to those in no fuel injection. As equivalence ratio is increased, static pressures are increased in the duct. In the similar equivalence ratio, static pressures are increased when total enthalpy is decreased. For reacting flow, the flame is occurred near the cavity. The combustion is weak locally in the middle of the duct. The up and down pressure distribution in the duct means that the supersonic combustion is generated.

  • PDF

A Study of Flow and Mixing in a Static Mixer (스태틱 믹서의 유동 및 혼합에 대한 연구)

  • Yang, Hei-Cheon;Park, Sang-Kyoo;Eom, Yong-Suk;Ra, Byeong- Yeol
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.557-562
    • /
    • 2001
  • Fluid mixing is ubiquitous and essential in many natural and industrial systems. Understanding the mixing processes that occur in these diverse system is essential for predicting many aspects of practical importance. The objective of this study is to perform the experimental and numerical investigation of the flow and mixing in a static mixer. Three different types of mixing elements, Sulzer, SSM and PPM were used. Glycerin and hydraulic oil were used as mixing fluids. Pressure drop was measured using a manometer.

  • PDF