• Title/Summary/Keyword: Static Weak Point

Search Result 24, Processing Time 0.02 seconds

Numerical investigation seismic performance of rigid skewed beam-to-column connection with reduced beam section

  • Zareia, Ali;Vaghefi, Mohammad;Fiouz, Ali R.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.3
    • /
    • pp.507-528
    • /
    • 2016
  • Reduced beam section (RBS) moment resisting connections are among the most economical and practical rigid steel connections developed in the aftermath of the 1994 Northridge and the 1995 Kobe earthquakes. Although the performance of RBS connection has been widely studied, this connection has not been subject to in the skewed conditions. In this study, the seismic performance of dogbone connection was investigated at different angles. The Commercial ABAQUS software was used to simulate the samples. The numerical results are first compared with experimental results to verify the accuracy. Nonlinear static analysis with von Mises yield criterion materials and the finite elements method were used to analyze the behavior of the samples The selected Hardening Strain of materials at cyclic loading and monotonic loading were kinematics and isotropic respectively The results show that in addition to reverse twisting of columns, change in beam angle relative to the central axis of the column has little impact on hysteresis response of samples. Any increase in the angle, leads to increased non-elastic resistance. As for Weak panel zone, with increase of the angle between the beam and the column, the initial submission will take place at a later time and at a larger rotation angle in the panel zone and this represents reduced amount of perpendicular force exerted on the column flange. In balanced and strong panel zones, with increase in the angle between the beam and the central axis of the column, the reduced beam section (RBS), reaches the failure limit faster and at a lower rotation angle. In connection of skewed beam, balanced panel zone, due to its good performance in disposition of plasticity process away from connection points and high energy absorption, is the best choice for panel zone. The ratio of maximum moment developed on the column was found to be within 0.84 to 1 plastic anchor point, which shows prevention of brittle fracture in connections.

Correlation Analysis between Rut Resistance and Deformation Strength for Superpave Mixtures (수퍼페이브 혼합물의 소신변형저항성과 변형강도와의 상관성분석)

  • Kim, K.W.;Kim, S.T.;Kwon, O.S.;Doh, Y.S.
    • International Journal of Highway Engineering
    • /
    • v.6 no.4 s.22
    • /
    • pp.45-53
    • /
    • 2004
  • This study dealt with correlation analysis between deformation strength and rut resistance of asphalt concretes based on binder grade in Superpave specification with changing submerging time. Currently, Mashall mix design is known to have little correlation with rutting related performance. Therefore, some agencies started to use the Superpave method for asphalt mix design. But this method has a weak point in that it can not distinct mechanical property of the asphalt mixtures designed. For solution of these problem, this study used deformation strength, $S_D$, of Kim test which is a new approach under development for finding property which represents rut resistance characteristics of asphalt mixtures under static loading. This study used two aggregates from two regions and five PG asphalt binders. Final rut depth (DR) and dynamic stability (DS) from wheel tracking (WT) test were obtained. and $S_D$ value of the same mixture specimen which was made by gyratory compactor was obtained using loading head [4(1.0)]. Three submerging times 30min, 40min, 50min were used as a test variable at $60^{\circ}C$. Correlation analysis of DR and DS with $S_D$ were performed based on PG grade. It was found out that the $S_D$ has a high correlation with DR and DS of superpave mixtures. The highest $R^2$ was found from the $S_D$ values of 30min. submerged specimen.

  • PDF

An On-chip ESD Protection Method for Preventing Current Crowding on a Guard-ring Structure (가드링 구조에서 전류 과밀 현상 억제를 위한 온-칩 정전기 보호 방법)

  • Song, Jong-Kyu;Jang, Chang-Soo;Jung, Won-Young;Song, In-Chae;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.12
    • /
    • pp.105-112
    • /
    • 2009
  • In this paper, we investigated abnormal ESD failure on guard-rings in the smart power IC fabricated with $0.35{\mu}m$ Bipolar-CMOS-DMOS (BCD) technology. Initially, ESD failure occurred below 200 V in the Machine Model (MM) test due to current crowding in the parasitic diode associated with the guard-rings which are generally adopted to prevent latch-up in high voltage devices. Optical Beam Induced Resistance Charge (OBIRCH) and Scanning Electronic Microscope (SEM) were used to find the failure spot and 3-D TCAD was used to verify cause of failure. According to the simulation results, excessive current flows at the comer of the guard-ring isolated by Local Oxidation of Silicon (LOCOS) in the ESD event. Eventually, the ESD failure occurs at that comer of the guard-ring. The modified comer design of the guard-ring is proposed to resolve such ESD failure. The test chips designed by the proposed modification passed MM test over 200 V. Analyzing the test chips statistically, ESD immunity was increased over 20 % in MM mode test. In order to avoid such ESD failure, the automatic method to check the weak point in the guard-ring is also proposed by modifying the Design Rule Check (DRC) used in BCD technology. This DRC was used to check other similar products and 24 errors were found. After correcting the errors, the measured ESD level fulfilled the general industry specification such as HBM 2000 V and MM 200V.

Fatigue Analysis for Levitation Rail of Urban Maglev System (도시형 자기부상열차 부상레일의 피로해석)

  • Kim, Kyung-Taek;Kim, Jae-Yong;Kim, Yong-Hwan;Park, Jin-Soo;Pyen, Sang-Yun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.39-45
    • /
    • 2008
  • A levitation rail is placed on the top of track structure to operate Maglev vehicles and a part of track that link up with a sleeper is applied repeated load in Maglev vehicles operation. This paper aimed to verify validity of design for levitation rail, through the fatigue analysis about load which is applied to levitation rail in Maglev vehicles operation and impact load occurring in an emergency landing. Load conditions applied design load(23kN/m) in normal operation and skid drop load(24kN/m) in vehicle drop. And boundary conditions are consider bolt fixing and welding. Through static analysis, weak point and maximum stress of levitation rail could be obtained. S-N(stress-life) method was used in oder to predict fatigue life, and Goodman relationship was applied to consider a effect of mean stress. Also damage was calculated by using Miner's. As a result of fatigue analysis, levitation rail had a fatigue life which was more than requirement ($10^6$cycle) in all analysis conditions. Assumption that $10^8{\sim}10^9$cycles is infinite life, all analysis conditions had infinite life except a case under drop load and bolt fixing($1.21{\times}10^6$).

  • PDF