송전선로의 이용률 평가 및 합리적 운영에 관한 연구 (A Study on Utilization Ratio and Operation of Transmission Lines)

  • 김동민;배인수;조종만;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.426-432
    • /
    • 2006
  • This paper describes the concepts of Static Line Rating (SLR) and Dynamic Line Rating (DLR) and the computational methods to demonstrate them. Calculation of the line capacity needs the heat balance equation which is also used for computing the reduced tension in terms of line aging. SLR is calculated with the data from the worst condition of weather throughout the year. Even now, the utilization ratio is obtained from this SLR data in Korea. DLR is the improved method compared to SLR. A process for DLR reveals not only improved line ratings but also more accurate allowed line ratings based on line aging and real time conditions of weather. In order to reflect overhead transmission line aging in DLR, this paper proposes the method that considers the amount of decreased tension since the lines have been installed. Therefore, the continuous allowed temperature for remaining life time is newly acquired. In order to forecast DLR, this paper uses weather forecast models, and applies the concept of Thermal Overload Risk Probability (TORP). Then, the new concept of Dynamic Utilization Ratio (DUR) is defined, replacing Static Utilization Ratio (SUR). For the case study, the two main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area are chosen for computing line rating and utilization ratio. And then line rating and utilization ratio are analyzed for each transmission line, so that comparison of the present and estimated utilization ratios becomes available. Finally, this paper proves the validity of predictive DUR as the objective index, with simulations of emergency state caused by system outages, overload and so on.

가공송전선의 송전용량을 증가시키기 위한 동적송전용량 시스템의 설계 (A Design for Dynamic Line Rating System to increase Overhead Transmission Line Capacities)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.72-77
    • /
    • 2011
  • Dynamic Line Rating (DLR) techniques have been greatly worthy of notice for efficiently increasing transmission capacity as well as controlling load-flow in overhead transmission lines, in comparison with the existing power system operating with Static Line Rating (SLR). This paper describes an utilization method to implement DLR control system for old transmission lines built in the first stage using the ground clearance design standard with lower dips. The suggested DLR system is focused on designing as temperature control system rather than current/load control system. Based on several performance for conductor temperatures, it is shown that DLR system with efficiency can be implemented.

가공송전선로의 AAR 적용 시 Risk Tolerance 분석을 이용한 계절별 최대 허용전류 산정 및 적용에 관한 연구 (Study on the Estimation of Seasonal Ambient Current for the Application of Ambient Adjusted Line Rating(AAR) in Overhead Transmission Lines Using Risk Tolerance(RT) Method)

  • 이재걸;배영재;송지영;신정훈;김용학;김태균;윤용범
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.7-15
    • /
    • 2017
  • Ambient Adjusted line Rating(AAR) method for overhead transmission lines considering Risk Tolerance(RT) was proposed in this paper. AAR is suitable for system operators to plan their operation strategy and maintenance schedule because this can be designed as a seasonal line rating. Several candidate transmission lines are chosen to apply the proposed method in the paper. As a result, it is shown that system reliability was significantly enhanced through maximizing transfer capability, solving the system constraints.

가공송전선로의 비상용량 응용과 평가 (Application and Evaluation of Emergency Rates in Overhead Transmission Lines)

  • 김성덕
    • 전기전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.442-446
    • /
    • 2014
  • 본 논문에서는 ACSR 가공송전선로의 전력공급 신뢰도를 증진시키기 위한 비상정격의 적용방안에 대하여 기술하였다. 전력산업의 재편으로 인하여 한국전력은 물론 세계의 대부분 전력회사들은 새로운 투자를 하지 않으면서 경제적인 전략들만 모색하여 왔다. 그러나 전력수요가 급격히 증가하였으나 발전량의 증가는 충분히 따라가지 못했다. 따라서 첨두부하 시나 송전선로의 고장의 경우에 기존 송전선로의 송전용량을 증가시키기 위하여, 단시간 또는 장시간정격과 같은 비상용량을 적용하는 방법을 제안한다. 만약 첨두부하시, 정적송전용량 대신에 장시간 비상용량을 적용하면 10 % 또는 그 이상의 전력증대가 가능하다. 또한 2회선 송전선로 중 1회선 고장이나 과부하 경우에 비상용량이 효과적으로 사용될 수 있음을 확인하였다.

한국전력 가공송전선의 허용전류를 증가시키기 위한 기상모델의 평가 (An Evaluation of Weather Model for Increasing Ampacity in KEPCO's Overhead Transmission Lines)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.125-134
    • /
    • 2004
  • 전력설비 시장의 새롭게 조정된 경제환경으로 인하여 송전선로에 대한 투자와 운용 정책에 근본적인 변화가 초래되었다. 따라서, 최악의 기상조건을 사용하는 형식적인 가정들을 토대로 주어지는 도체의 허용전류를 증가시키기 위하여 현재 설비를 평가하는 것이 중요하게 되었다. 여전히 세계의 대부분 전력회사에서는 정적송전용량을 채용하고 있지만, 몇몇 회사들은 송전용량을 증가시키기 위하여 동적송전용량을 실시간으로 모니터링 하는 등 다양한 시도를 해왔다. 이 연구는 기상모델로 규정된 한국전력공사(KEPCO)의 송전선로의 정적송전용량을 평가하기 위한 시도이다. 과거 기상청에서 관측된 기상 데이터를 근거로 송전용량을 결정하기 위한 몇 가지 환경적 특성을 검토하였다. 그 결과, 한국전력의 송전선로에 계절별 또는 지역별 정격을 적용할 수 있으며, 현재 운용 중인 도체를 새로운 고내열 도체로 교체하지 않더라도 기존 송전용량을 좀더 증대시킬 수 있음을 확인하였다.

A Cascaded D-STATCOM Integrated with a Distribution Transformer for Medium-voltage Reactive Power Compensation

  • Lei, Ertao;Yin, Xianggen;Chen, Yu;Lai, Jinmu
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.522-532
    • /
    • 2017
  • This paper presents a novel integrated structure for a cascaded distribution static compensator (D-STATCOM) and distribution transformer for medium-voltage reactive power compensation. The cascaded multilevel converter is connected to a system via a group of special designed taps on the primary windings of the Dyn11 connection distribution transformer. The three-phase winding taps are symmetrically arranged and the connection point voltage can be decreased to half of the line-to-line voltage at most. Thus, the voltage stress for the D-STATCOM is reduced and a compromise between the voltage rating and the current rating can be achieved. The spare capacity of the distribution transformer can also be fully used. The working mechanism is explained in detail and a modified control strategy is proposed for reactive power compensation. Finally, both simulation and scaled-down prototype experimental results are provided to verify the feasibility and effectiveness of the proposed connection structure and control strategy.

Study on Thermal Load Capacity of Transmission Line Based on IEEE Standard

  • Song, Fan;Wang, Yanling;Zhao, Lei;Qin, Kun;Liang, Likai;Yin, Zhijun;Tao, Weihua
    • Journal of Information Processing Systems
    • /
    • 제15권3호
    • /
    • pp.464-477
    • /
    • 2019
  • With the sustained and rapid development of new energy sources, the demand for electric energy is increasing day by day. However, China's energy distribution is not balanced, and the construction of transmission lines is in a serious lag behind the improvement of generating capacity. So there is an urgent need to increase the utilization of transmission capacity. The transmission capacity is mainly limited by the maximum allowable operating temperature of conductor. At present, the evaluation of transmission capacity mostly adopts the static thermal rating (STR) method under severe environment. Dynamic thermal rating (DTR) technique can improve the utilization of transmission capacity to a certain extent. In this paper, the meteorological parameters affecting the conductor temperature are analyzed with the IEEE standard thermal equivalent equation of overhead transmission lines, and the real load capacity of 220 kV transmission line is calculated with 7-year actual meteorological data in Weihai. Finally, the thermal load capacity of DTR relative to STR under given confidence is analyzed. By identifying the key parameters that affect the thermal rating and analyzing the relevant environmental parameters that affect the conductor temperature, this paper provides a theoretical basis for the wind power grid integration and grid intelligence. The results show that the thermal load potential of transmission lines can be effectively excavated by DTR, which provides a theoretical basis for improving the absorptive capacity of power grid.

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

Optimal Particle Swarm Based Placement and Sizing of Static Synchronous Series Compensator to Maximize Social Welfare

  • Hajforoosh, Somayeh;Nabavi, Seyed M.H.;Masoum, Mohammad A.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.501-512
    • /
    • 2012
  • Social welfare maximization in a double-sided auction market is performed by implementing an aggregation-based particle swarm optimization (CAPSO) algorithm for optimal placement and sizing of one Static Synchronous Series Compensator (SSSC) device. Dallied simulation results (without/with line flow constraints and without/with SSSC) are generated to demonstrate the impact of SSSC on the congestion levels of the modified IEEE 14-bus test system. The proposed CAPSO algorithm employs conventional quadratic smooth and augmented quadratic nonsmooth generator cost curves with sine components to improve the accurate of the model by incorporating the valve loading effects. CAPSO also employs quadratic smooth consumer benefit functions. The proposed approach relies on particle swarm optimization to capture the near-optimal GenCos and DisCos, as well as the location and rating of SSSC while the Newton based load flow solution minimizes the mismatch equations. Simulation results of the proposed CAPSO algorithm are compared to solutions obtained by sequential quadratic programming (SQP) and a recently implemented Fuzzy based genetic algorithm (Fuzzy-GA). The main contributions are inclusion of customer benefit in the congestion management objective function, consideration of nonsmooth generator characteristics and the utilization of a coordinated aggregation-based PSO for locating/sizing of SSSC.

Performance Analysis of SSSC with Switching-level Simulation Model and Scaled Hardware Model

  • Han, Byung-Moon;Kim, Hee-Joong;Baek, Seung-Taek
    • Journal of Power Electronics
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 2001
  • This paper describes a switching-level simulation model and scaled hardware model for SSSC, which is useful for analyzing the dynamic interaction between the SSC and the power transmission system. A detailed simulation model with EMTP was developed to verity the SSSC operation with control system, and its increasing capability of power transmission through the line for a typical one-machine infinite-bus system. The simulation results of the developed model are compared with the experimental results froma scaled model fo 2KVA rating for evaluation the whole system operation.