• Title/Summary/Keyword: Start Motor

Search Result 289, Processing Time 0.031 seconds

Optimal Design and Dynamic Characteristic Analysis of Line Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기전동기의 최적설계 및 동특성 해석)

  • Kim, Do-Sun;Kim, Byong-Kuk;Lee, Byung-Jun;Cho, Youn-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.92-94
    • /
    • 2008
  • The interest in permanent magnet synchronous motor is present in a wide area of applications, ranging from high-performance servo drive to line-start application[1]. The are mainly two reasons for this trend: first low rotor losses and second the foiling prices of high-energy magnets. In this paper the dynamic characteristic of the line-start permanent magnet synchronous motor are described and compared with those if the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bar in the line-start permanent magnet synchronous motor.

  • PDF

Optimal Design for Starting-Torque of Line Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기 전동기의 기동 토크 최적화 설계)

  • Kim, Byong-Kuk;Hwang, Dong-Won;Kim, Tae-Hyun;Jo, Won-Yung;Lee, In-Jae;Han, Sung-Jin;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.930-932
    • /
    • 2005
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

A study on the Rotor Design in Single-phase Line-start Permanent Magnet Motor (단상 유도형 동기전동기의 회전자 설계에 관한 연구)

  • Kim, Won-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • The purpose of this paper is the rotor design of a single-phase LSPM(Line-start permanent magnet) motor. A single-phase LSPM motor has a permanent magnet in the rotor that is same as induction motor. For that reason, magnet is operated by breaking torque in starting region and alignment torque in driving region. Therefore, we need the design process considering the trade-off relationship. In this paper, we propose the design process of a single-phase LSPM motor for a high starting torque and efficiency with FEM. And we use Taguchi Method for considering tolerance in manufacture. Finally, we compared the LSPM motor that is designed in this paper and conventional induction motor.

Auxiliary Winding Optimization of Single Phase Line-Start Permanent Magnet Motor to Torque Ripple Reduction (Single Phase Lien Start Permanent Magnet Motor의 토크리플 저감을 위한 보조 권선 최적화)

  • Kang, Min-Chul;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.814-815
    • /
    • 2015
  • 본 논문에서는 단상 LSM(Line-Start Permanent Magnet Motor)의 토크리플 저감을 위하여 고정자 슬롯의 보조권선의 턴 수의 배치를 최적화 하였다. 보조권선의 최적화 과정은 고정자 슬롯 보조권선의 턴수 배치를 통하여 고정자 자속이 가장 정현파에 가까워지는 권선배치를 선정하였으며, DOE(Design of Experiment)를 통해 수행하였다. FEM(Finite Element Method)을 통하여 기존 모델과 최적화 모델의 특성을 비교 검토하였다.

  • PDF

Soft Start System of Induction Motor using Emergency Generator (비상 발전기를 이용한 유도전동기의 소프트 기동 시스템)

  • Hwangbo, Chan;Ko, Jae-Ha;Lee, Jung-Hwan;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.433-441
    • /
    • 2022
  • In general, in an emergency generator system for an electric facility including an induction motor load, an emergency power generation facility larger than the facility load capacity is built due to the initial starting current of the induction motor. In order to reduce this economic burden, various methods to reduce the inrush current of induction motors are applied to suppress the additional expansion of generators due to the reduction of power generation facilities and the increase in electrical facilities. Among these methods, when a system with a built-in soft start function of an induction motor using an inverter is built, it is the best way to reduce the inrush current of the induction motor to less than the rated current. However, in this case, the installation cost of the inverter to drive the induction motor increases. This paper proposes a soft start method of an induction motor by expanding the frequency and voltage control operation area of an emergency generator. In addition, proposed a speed calculation method based on power factor information, which is essential information for stable soft start of an induction motor, and a method for generating a speed command value of the governor for starting with maximum torque.

Comparison of the Single-phase Line-start Permant Magnet Motor's Transient Characteristics by Size and Position of Rotor Bar (영구자석 매입형 단상 유도 동기 전동기의 회전자 바의 크기와 위치에 따른 기동 특성 비교)

  • Kwon, S.H.;Yang, B.Y.;Kwon, B.I.;Lee, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.933-935
    • /
    • 2003
  • The single-phase line start permanent magnet motor(LSPM) have a rotor cage bar for induction starting and permanent magnets, providing synchronous torque. So, LSPM is vary complex and difficult to analysis transient characteristics and rotor design. In this paper, F.E.M analysis about single-phase line start permanent magnet motor and compare of the single-phase line start permanent magnet synchronous motor's transient characteristics by size and position of rotor bar.

  • PDF

Character Analysis for Break-Torque of Line-Start Permanent Magnet Synchronous Motors (직립 기동 영구자석 동기 전동기의 브레이크 토크 특성 해석)

  • Kim, Byung-Kuk;Kim, Tae-Hyun;Jo, Won-Yung;Lee, In-Jae;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.86-88
    • /
    • 2005
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor arc described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

A Comparison of LSPM Synchronous Motor and Induction Motor (LSPM 동기전동기와 유도전동기의 특성 비교)

  • Kim, Byong-Kuk;Jo, Won-Yung;Lee, In-Jae;Moon, Ji-Woo;Kim, Mi-Jung;Lim, Seong-Hwan;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.829-830
    • /
    • 2006
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

A Comparative Study of the Line Start Permanent Magnet, Skeleton Type Brushless DC, and Snail-earn Type Switched Reluctance Motor for Fans

  • Lee, Ji-Young;Lee, Geun-Ho;Hong, Jung-Pyo;Jin Hur
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.122-126
    • /
    • 2004
  • The objective of this paper is to provide a comparison between the Line Start Permanent Magnet, Skeleton type Brushless DC, and the Snail-cam type Switched Reluctance Motor. These motors are compared under the same load characteristic as the cooling fan motor of a refrigerator. The comparison consists of speed, output power, efficiency, copper loss, and cost for three different motors. For the given application, the results provide an indication of the best machine suited with respect to performance and cost.

Characteristic Analysis & Design of Line start Synchronous Reluctance Motor to substitute for Induction Motor (유도전동기 대체용 유도기동형 동기 릴럭턴스전동기의 특성해석 및 설계)

  • Oh, Young-Jin;Ryu, Sung-Lae;Lee, In-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.933-935
    • /
    • 2005
  • This study investigates Characteristic analysis of Line-start Synchronous Reluctance Motor to substitute for Induction Motor. The results of machine characteristics are analyzed by simulation using Flux2D. Characteristic analysis result of Line-start Synchronous Reluctance Motor is confirmed by the analysis result of 3-Phase Induction Motor.

  • PDF