• 제목/요약/키워드: Star-connected

검색결과 62건 처리시간 0.021초

Two Low-Loss Large Current Rectifiers Based on Low KVA Rating Wye-Connected Autotransformers

  • Meng, Fangang;Man, Zhongcheng;Li, Quanhui;Gao, Lei
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1697-1707
    • /
    • 2018
  • In this paper, two large current rectifiers are proposed based on two wye-connected autotransformers. The requirements of the ideal large current rectifier are analyzed, and it is concluded that the large current rectifier has a higher power density and a higher energy conversion efficiency when it is made up of two three-phase half-wave rectifiers and a wye-connected autotransformer. According to theoretical analysis results, the two novel wye-connected autotransformers are designed to feed two three-phase half-wave rectifiers. The two autotransformers can generate two groups of three-phase voltages with a 60o phase shifting, and their kVA ratings account for 95% and 80% of the load power, respectively. These values are less than those of a double star rectifier at 30% and 46%. From the input mains and output side, the power quality of the proposed rectifiers is the same as that of the double star rectifier. Some experiments validate the correctness of the theoretical analysis.

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

Performance Evaluation of the Field-Oriented Control of Star-Connected 3-Phase Induction Motor Drives under Stator Winding Open-Circuit Faults

  • Jannati, Mohammad;Idris, Nik Rumzi Nik;Aziz, Mohd Junaidi Abdul
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.982-993
    • /
    • 2016
  • A method for the fault-tolerant vector control of star-connected 3-phase Induction Motor (IM) drive systems based on Field-Oriented Control (FOC) is proposed in this paper. This method enables the control of a 3-phase IM in the presence of an open-phase failure in one of its phases without the need for control structure changes to the conventional FOC algorithm. The proposed drive system significantly reduces the speed and torque pulsations caused by an open-phase fault in the stator windings. The performance of the proposed method was verified using MATLAB (M-File) simulation as well experimental tests on a 1.5kW 3-phase IM drive system. This paper experimentally compares the operation of the proposed fault-tolerant vector controller and a conventional vector controller during open-phase fault.

밀리미터파 응용을 위한 우수한 성능의 MMIC Star 혼합기 (High Performance MMIC Star Mixer for Millimeter-wave Applications)

  • 류근관;염인복;김성찬
    • 한국통신학회논문지
    • /
    • 제36권10A호
    • /
    • pp.847-851
    • /
    • 2011
  • 본 논문에서는 밀리미터파 응용에서 사용 가능한 우수한 성능의 MMIC (Millimeter-wave Monolithic Integrated Circuit) star 혼합기를 구현하였다. MMIC star 혼합기를 구현하기 위하여 PHEMT (pseudomorphic high electron mobility transistor) 공정 기반의 소오스와 드레인 단자를 연결한 쇼트키 (Schottky) 다이오드를 사용하였다. 혼합기의 측정 결과 LO 주파수가 75 GHz이며 전력이 10 dBm 인 경우, 81 GHz에서 86 GHz의 RF 주파수 범위에서 평균 13 dB의 변환손실 특성을 얻었다. RF-LO 격리도 특성은 30 dB 이상의 결과를 얻었으며 약 4 dBm의 P1 dB 특성을 얻었다. 전체 칩의 크기는 0.8 mm ${\times}$ 0.8 mm이다.

Does the SED of a galaxy constrain its merger history?

  • 이재현;이석영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.76.2-76.2
    • /
    • 2011
  • It is widely accepted that the SED of a galaxy relates to its morphology. In addition, the SED of the galaxy is closely connected to its star formation history, and its morphological properties are affected by the merger history, interactions with its environment, and the gravitational instability of its dynamical system. Thus, it is likely that star formation history correlates to the elements that determine morphological properties. Among the elements, this study investigates how much the merger histories of galaxies influence their star formation histories. By using simple merger trees and semi-analytic models, which disregard feedback processes to exclusively identify merger effects on star formation histories, we examine the relation between various merger histories and SEDs of galaxies. From the results, we discuss whether the SED of a galaxy can represent and constrain its merger history.

  • PDF

비대칭 이중층 셔플넷을 이용한 멀티홉 WDM Cross-Connected Star Topology (WDM Cross-Connected Star Topology using Asymmetric Bilayered ShuffleNet for Multihop Lightwave Network)

  • 지윤규
    • 대한전자공학회논문지SD
    • /
    • 제39권5호
    • /
    • pp.41-45
    • /
    • 2002
  • 비대칭 이중층 셔플넷 토폴로지를 멀티홉 WDM cross-connect 구현을 위하여 적용하였다. 그 결과로 필요한 WDM cross connect 수가 기존의 셔플넷 토폴로지 적용에 비하여 반으로 감소하며 이로 인하여 평균 흡수가 감소하고 평균 지연 시간을 줄일 수 있다.

Ring형 Network 설계문제의 휴리스틱 알고리즘 (Heuristic Algorithm for the Ring-type Network Design Problem)

  • 김길동;이경식
    • 산업경영시스템학회지
    • /
    • 제15권25호
    • /
    • pp.83-90
    • /
    • 1992
  • This paper aims at the problem that design the network of Rig-star type with the minimum cost, which the Ring is composed of the selected nodes(concentrators) among the several candidate nodes on the network and other nodes(terminals) is connected to the Ring by star subnetwork. Especially, we consider the terminal reliability in network design problem. We develop the heuristic algorithm for network design problem to obtain the near optimal(best) solution for problem. We use an add-heuristic method and 2-exchange method in developing the heuristic algorithm.

  • PDF

Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization

  • Ji, Zhendong;Zhao, Jianfeng;Sun, Yichao;Yao, Xiaojun;Zhu, Zean
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.946-956
    • /
    • 2014
  • Cascaded H-Bridge (CHB) converters can be directly connected to medium-voltage grids without using transformers and they possess the advantages of large capacity and low harmonics. They are significant tools for providing grid connections in large-capacity renewable energy systems. However, the reliability of a grid-connected CHB converter can be seriously influenced by the number of power switching devices that exist in the structure. This paper proposes a fault-tolerant control strategy based on double zero-sequence voltage injection and DC voltage optimization to improve the reliability of star-connected CHB converters after one or more power units have been bypassed. By injecting double zero-sequence voltages into each phase cluster, the DC voltages of the healthy units can be rapidly balanced after the faulty units are bypassed. In addition, optimizing the DC voltage increases the number of faulty units that can be tolerated and improves the reliability of the converter. Simulations and experimental results are shown for a seven-level three-phase CHB converter to validate the efficiency and feasibility of this strategy.

2상 쵸퍼 Preregulator를 갖는 12-step 인버터에서의 DC Link단 전압 불평형 해석 (Analysis of the Unbalance of DC Link Voltage in 12-step Inverter with 2-Phase Chopper Preregulator)

  • 노의철;김인동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.258-260
    • /
    • 1995
  • This paper deals with the voltage unbalance of DC link voltage in series connected two 6-step inverters with double chopper preregulator. Each output of the 6-step inverter is connected to each transformer. The secondary windings of one of the transformers is zig-zag connected and the other star connected. The secondary terminals of the two transformers are series connected which makes 12-step output voltage waveform. In this case, the characteristics of the two transformers are rather different each other. The difference results in the voltage unbalance of the two 6-step inverter input capacitor voltages which make the DC link voltage. The degree of the voltage unbalance is analysied with the variations of load power, load power factor and % impedance of the transformer.

  • PDF

STAR FORMATION RATE CALIBRATIONS FOR WISE LUMINOSITIES

  • Yuan, F.T.;Takeuchi, T.T;Buat, V.;Burgarella, D.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.345-346
    • /
    • 2012
  • Starting from an infrared selected GALEX-SDSS-2MASS-AKARI sample of local star forming galaxies, we built mock samples from redshift 0 to 2.5 to investigate star formation rate (SFR) calibrations using WISE luminosities. We find W3 and W4 band fluxes can indicate SFRs with small scatters when the rest-frame wavelengths are longer than ${\sim}6{\mu}m$. When the wavelength becomes shorter, the observed luminosities are more tightly connected to the emission of old stellar populations than dust, therefore lose the reliability to trace the SFR. The current SFR calibrations are consistent with previous studies.