A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

A Study on the Optimization of Field Sampling Number of the Durability Evaluation Method for the Extension Remodeling of the Apartment Housing (공동주택의 증축형 리모델링 안전진단 내구성 평가의 표본 수 최적화 방안 연구)

  • Shin, Heechul;Choi, Kibong;Yoon, Sangchun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.60-68
    • /
    • 2018
  • The Housing Act amended allows vertical extension up to three floors and increases the units of housing (or total floor area) to site up to 15%. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with preliminary investigations on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation methodology for the preliminary investigation is still required because the current procedures are borrowed from safety diagnosis provisions and manuals for reconstruction without detailed examinations on evaluation criteria and sampling methods. Accordingly, this study is intended to suggest a method to obtain feasible sampling size for durability assessment by statistically analyzing the safety evaluation data sets on concrete carbonation and steel corrosion obtained from apartment complexes. The results of this study are expected to be beneficial for establishing more reasonable field sampling size, and in turn, more reliable durability assessment protocol for vertical extension.

Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment (건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대)

  • Roh, Young-Man;Lee, Cheol Min;Kim, Yoon Shin;Kim, Seok Won;Kim, Chi-Nyon;Kim, Hyun-Wook;Cho, Kee Hong;Choi, Ho Chun;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

A Study on Design Preference for the Sales Spaces of Duty-Free Shops by the Examination of Image Evaluation - Cases of Duty-Free Shops in Jeju Special Self-governing Province -

  • Moon, Jung-Eun;Kim, Bong-Ae
    • Architectural research
    • /
    • v.12 no.2
    • /
    • pp.53-62
    • /
    • 2010
  • The purpose of this study is to examine design preferences for the sales spaces of duty-free shops (DFSs) by conducting image evaluations. The results will help improve quality by influencing designs for the construction, extension or remodeling of these shops. An image measurement method, the semantic differential method, was used to measure cognitive structure using photos of shops. Photos were collected of the DFS at Jeju Island, as well as photos of brand stores designed by architects. Two sets of 16 photos (32 different photos in all) were selected according to photo classification standards and design concepts, both decided by reviewing previous studies and related materials. The evaluation and survey were done by two sets of subjects: sales employees, who have experience and special knowledge of the evaluation of sales space; and students majoring in architecture. To strengthen the evaluation results, I conducted a preliminary survey and a main survey, verifying and complementing findings. 116 surveys were conducted, of which 14 were of poor quality and rejected, leaving and 102 to be analyzed. The collected surveys were statistically analyzed, using SPSS 12.0 for Windows. Reliability, image profile, factor and multi-dimensional scaling analyses were conducted. As a result, image evaluation structure and characteristics were obtained for sales spaces of DFSs, confirming the difference between them and other spaces.