• Title/Summary/Keyword: Standardized Reference Model

Search Result 46, Processing Time 0.021 seconds

A Study on the Reference Model for Integrated Urban Spatial Information Management Platform (지능형 도시공간정보 통합플랫폼 참조모델 개발 연구)

  • Hong, Sang-Ki;Cho, Sung-Youn
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.4
    • /
    • pp.19-27
    • /
    • 2009
  • Integrated Urban Spatial Information Management Platform (USIMP) is defined as an operational environment where technologies for intelligent management of urban facilities are made possible through the integration of diverse technologies such as sensors for ground and underground facilities, middleware technology, wired and wireless network, GIS-USN linkage. To make the integration of these diverse technology possible, it is imperative to have a sound reference model for the platform. This paper provides a standardized reference model for USIMP based on the RM-OPD(Reference Model for Open Distributed Processing) standard.

  • PDF

Reference Model and Architecture of Interactive Cognitive Health Advisor based on Evolutional Cyber-physical Systems

  • Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4270-4284
    • /
    • 2019
  • This study presents a reference model (RM) and the architecture of a cognitive health advisor (CHA) that integrates information with ambient intelligence. By controlling the information using the CHA platform, the reference model can provide various ambient intelligent solutions to a user. Herein, a novel approach to a CHA RM based on evolutional cyber-physical systems is proposed. The objective of the CHA RM is to improve personal health by managing data integration from many devices as well as conduct a new feedback cycle, which includes training and consulting to improve quality of life. The RM can provide an overview of the basis for implementing concrete software architectures. The proposed RM provides a standardized clarification for developers and service designers in the design and implementation process. The CHA RM provides a new approach to developing a digital healthcare model that includes integrated systems, subsystems, and components. New features for chatbots and feedback functions set the position of the conversational interface system to improve human health by integrating information, analytics, and decisions and feedback as an advisor on the CHA platform.

A Method to Evaluate Information System Interoperability Based on Technical Reference Model (기술참조모델 기반의 정보시스템간의 상호운용성 평가 방법)

  • Park, Sung-Bum;Choi, Nam-Yong
    • Information Systems Review
    • /
    • v.5 no.2
    • /
    • pp.183-202
    • /
    • 2003
  • In this paper, we designed an interoperability evaluation system based on technical reference model, HanTRM (Technical Reference Model) and the information technology architecture methodology, TAProcess (Technical Architecture Process). TAProcess provides standardized procedure and methodology for the efficient installation, management and operation of information technology. HanTRM can be used as a referencial basic framework for all organizations which are starting to make technical reference model. We propose a method that utilize HanTRM and a procedure that evaluates interoperability between information systems to design interoperbility evaluation system. So, this interoperbility evaluation system will be more usefully applied to organizations.

A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners

  • Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.63-69
    • /
    • 2022
  • PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.

Technical Assessment of Component Reference Models (컴포넌트 참조 모델의 기술적 비교 평가)

  • 허진선;김수동
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.6
    • /
    • pp.697-715
    • /
    • 2004
  • Component-Based Development (CBD) is a reuse technology Providing enhancement in productivity through using the unit of component which is larger-grained than an object. However, reference model defining the elements and semantics of CBD component is standardized neither internationally nor in industrial. This yields interoperability and portability problem between CBD platforms, and presents burden of choosing appropriate model to developers. In this paper, we define meta-models for representative component reference models, and identify advantages, disadvantages, and features of each model through technical comparison of meta-models. Besides, through a proposal of essential component model containing common and essential elements that all component models must conform and a extended component model containing maximum elements and mechanisms, we can precisely assess candidate component models in practice.

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

A standardization model based on image recognition for performance evaluation of an oral scanner

  • Seo, Sang-Wan;Lee, Wan-Sun;Byun, Jae-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.409-415
    • /
    • 2017
  • PURPOSE. Accurate information is essential in dentistry. The image information of missing teeth is used in optically based medical equipment in prosthodontic treatment. To evaluate oral scanners, the standardized model was examined from cases of image recognition errors of linear discriminant analysis (LDA), and a model that combines the variables with reference to ISO 12836:2015 was designed. MATERIALS AND METHODS. The basic model was fabricated by applying 4 factors to the tooth profile (chamfer, groove, curve, and square) and the bottom surface. Photo-type and video-type scanners were used to analyze 3D images after image capture. The scans were performed several times according to the prescribed sequence to distinguish the model from the one that did not form, and the results confirmed it to be the best. RESULTS. In the case of the initial basic model, a 3D shape could not be obtained by scanning even if several shots were taken. Subsequently, the recognition rate of the image was improved with every variable factor, and the difference depends on the tooth profile and the pattern of the floor surface. CONCLUSION. Based on the recognition error of the LDA, the recognition rate decreases when the model has a similar pattern. Therefore, to obtain the accurate 3D data, the difference of each class needs to be provided when developing a standardized model.

Non-Reference P Frame Coding for Low-Delay Encoding in Internet Video Coding (IVC의 저지연 부호화 모드를 위한 비참조 P 프레임의 부호화 기법)

  • Kim, Dong-Hyun;Kim, Jin-Soo;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.250-256
    • /
    • 2014
  • Non-reference P frame coding is used to enhance coding efficiency in low-delay encoding configuration of Internet Video Coding (IVC), which is being standardized as a royalty-free video codec in MPEG. The existing method of non-reference P frame coding which was adopted in the reference Test Model of IVC (ITM) 4.0 adaptively applies a non-reference P frame with a fixed coding structure based on the magnitude of motion vectors (MVs), however, which unexpectedly degrades the coding efficiency for some sequences. In this paper, the existing non-reference P frame coding is improved by changing non-reference P frame coding structure and applying a new adaptive method using the ratio of the amount of generated bits of non-reference frames to that of reference frames as well as MVs. Experimental results show that the proposed non-reference P frame coding gives 6.6% BD-rate bit saving in average over ITM 7.0.

System Construction and Data Development of National Standard Reference for Renewable Energy - Model-Based Standard Meteorological Year (신재생에너지 국가참조표준 시스템 구축 및 개발 - 모델 기반 표준기상년)

  • Boyoung Kim;Chang Ki Kim;Chang-yeol Yun;Hyun-goo Kim;Yong-heack Kang
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.95-101
    • /
    • 2024
  • Since 1990, the Renewable Big Data Research Lab at the Korea Institute of Energy Technology has been observing solar radiation at 16 sites across South Korea. Serving as the National Reference Standard Data Center for Renewable Energy since 2012, it produces essential data for the sector. By 2020, it standardized meteorological year data from 22 sites. Despite user demand for data from approximately 260 sites, equivalent to South Korea's municipalities, this need exceeds the capability of measurement-based data. In response, our team developed a method to derive solar radiation data from satellite images, covering South Korea in 400,000 grids of 500 m × 500 m each. Utilizing satellite-derived data and ERA5-Land reanalysis data from the European Centre for Medium-Range Weather Forecasts (ECMWF), we produced standard meteorological year data for 1,000 sites. Our research also focused on data measurement traceability and uncertainty estimation, ensuring the reliability of our model data and the traceability of existing measurement-based data.

Development of Business Process Model based on the e-Marketplace in Retail Industry (e-Marketplace 중심의 유통산업 비즈니스 프로세스 표준모형 개발)

  • 임춘성;홍정완;박윤정;김유석
    • Proceedings of the CALSEC Conference
    • /
    • 2001.08a
    • /
    • pp.259-276
    • /
    • 2001
  • The B2B e-Marketplace connected a number of suppliers and buyers offers the opportunity to form more flexible supply chain and requires to transform the business process of purchasing transactions between suppliers and buyers to new environment. So, firms in e-Marketplace will become increasingly aware of need to improve and extend their existing processes. In order to provide the reference model for these firms, we have developed a standardized model of business process for retail industry that incorporates several important features of purchasing process in e-Marketplace. The paper describes these features and discusses the use of the model in retail industry.

  • PDF