양생온도에 따른 다공성 경량골재를 활용한 샌드위치 패널심재의 강도 특성 (Strength Properties of Sandwich Panel core using Cellular lightweight Aggregate according to Curing Temperature)

  • 노정식;김대규;도정윤;문경주;소양섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.35-38
    • /
    • 2003
  • The purpose of this study is to investigate the manufacture of light weight concrete panel using the artificial light-weight aggregate as a part of the substitution of foamed styrene and polyurethane because of narrow allocable temperature Bone in use. The experimental parameter of this study is 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity and the type of admixture such as cement, 6mm glass fiber and St/BA emulsion. Testing item is compressive and flexural strength and strength of specimen cured at standard condition is compared to that of specimen cured at 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity. As a result or this, it was revealed that the maximum or strength is developed in 6$0^{\circ}C$ or cure temperature at 100% relative humidity in case of the most of the specimen. Specimens modified by St/BA emulsion show the highest development of strength dependent on the curing tmeperature. So, it seems to be effective that evaporation curing method shoud be considered to curing the specimen as the panel core.

  • PDF

Compressive Shear and Bending Performance of Compressed Laminated Wood after Microwave Heating

  • Park, Cheul-Woo;Lim, Nam-Gi
    • 한국건축시공학회지
    • /
    • 제12권5호
    • /
    • pp.539-547
    • /
    • 2012
  • To manufacture laminated wood with improved mechanical properties by providing uniform adhesiveness, the adhesive was applied and the plate adhesive was laminated on the wood surface. Then, after laminating the wood on the top part of the adhesivebond, it was heated and dried while the adhesive was stiffened using microwaves, and the test piece was manufactured by compressing it with the press machine for thirty minutes. The temperature and the water content were examined according to the heating time of the wood heated with the microwave, and testing was conducted on the shear strength and flexural strength of the wood. In addition, the microstructure of the adhesive bond between the wood was recorded to confirm the penetrabilityinto the wood structure for the adhesive. After the test was conducted, it was found that the test piece manufactured with wood that has its water content leveled with the microwave heating showed improved shear strength and bending strength compared to the standard test piece. With regard to adhesives, liquefied polyvinyl acetate resin and plate's PVB resin were found to have superior adhesive strength. Also, after filming the cellular microstructure, it was found that when the laminated wood is heated with microwaves, the infiltration of the adhesive into the inside of the wood becomes easy, which makes it effective for improving adhesiveness.

규산질계 분말형 도포방수재의 내투수성 성능평가 연구 (Hydrostatic Pressure Resistance Performance Testing of Cement Mixed Siliceous Powder Waterproofing Coationgs)

  • 박소영;권시원;김수연;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.31-32
    • /
    • 2018
  • Lately, cement mixed siliceous powder waterproofing coating has been used as a waterproofing material in the wet environment condition of an underground concrete structure. Underground is exposed to environmental influences such as pressure of ground water, pressure of soil. However, the quality standard for pressure (water pressure, earth pressure) is not specified in the specification of the cement mixed siliceous powder waterproofing coating. Therefore, in this study, the permeability test was carried out based on the assumption that the durability should be verified in consideration of the environmental aspects of the material in actual field. As a result of the test, the permeability was generated from the inorganic single type material, but it was caused by the sealing failure and the test error, and the permeability was not generated in most of the materials. The results of this study will be analyzed by reviewing the physical properties of the material, and the research direction will be resumed.

  • PDF

Experimental work on seismic behavior of various types of masonry infilled RC frames

  • Misir, I. Serkan;Ozcelik, Ozgur;Girgin, Sadik Can;Kahraman, Serap
    • Structural Engineering and Mechanics
    • /
    • 제44권6호
    • /
    • pp.763-774
    • /
    • 2012
  • Reinforced concrete frame structures with masonry infill walls constitute the significant portion of the building stock in Turkey. Therefore it is very important to understand the behavior of masonry infill frame structures under earthquake loads. This study presents an experimental work performed on reinforced concrete (RC) frames with different types of masonry infills, namely standard and locked bricks. Earthquake effects are induced on the RC frames by quasi-static tests. Results obtained from different frames are compared with each other through various stiffness, strength, and energy related parameters. It is shown that locked bricks may prove useful in decreasing the problems related to horizontal and vertical irregularities defined in building codes. Moreover tests show that locked brick infills maintain their integrity up to very high drift levels, showing that they may have a potential in reducing injuries and fatalities related to falling hazards during severe ground shakings.

구조용 압연강(SS 400)의 고온 기계적 특성을 이용한 기둥부재의 내화성능 평가 (Evaluation of Fire Resistance Using Mechanical Properties at High Temperature for Steel Column Made of Rolled Steels (SS 400))

  • 권인규;신순기
    • 대한금속재료학회지
    • /
    • 제49권9호
    • /
    • pp.671-677
    • /
    • 2011
  • Steel columns used in steel buildings are inclined to lose their strength when exposed to severe fire conditions, so fire resistance is required in most countries to protect against loss of life and building collapses. In Korea, the fire resistance of columns can be obtained by the fire test defined in KS F 2257-1, 7. The fire resistance of a steel column should be evaluated in terms of the column's conditions, such as various section types (H-section, hollow-section), the column's length and boundary conditions, and whether it is fixed or hinged. However, fire testing of steel columns is usually conducted on one standard-sized H-section over 3,000 mm, and the result is used as the column's fire resistance. This is not a reasonable way to ensure that a building can withstand fire conditions. In this study, to evaluate the possibility of calculating the fire resistance of steel columns with material properties of high tensile strength of SS 400, both load-bearing fire tests and calculation of steel temperatures were carried out. The results of temperature calculation were very similar to those obtained by fire test.

실내 공기질 공정시험방법과 기준의 동시 개정에 따른 실란트 제품의 TVOC 관리수준 평가 (Evaluation of TVOC regulation level of sealant products in accordance with simultaneous revision of testing method and regulation value in the law of indoor air quality management)

  • 유지호;박준만;김만구
    • 분석과학
    • /
    • 제23권2호
    • /
    • pp.138-146
    • /
    • 2010
  • 환경부에서는 오염물질 다량 방출 건축자재의 효율적인 관리를 위해 다중이용시설 등의 실내 공기질 관리법의 시행 규칙 일부를 개정하였다. 특히 액상건축 자재인 실란트의 경우 시험방법과 초과기준이 함께 개정되어 기존 관리 수준과 개정 관리 수준의 직접적인 비교가 불가능하다. 따라서 이 연구에서는 실란트의 개정 시험방법의 각 요소들이 오염물질 방출강도에 미치는 영향과 타당성을 기존 시험방법에 대비하여 검토하였다. 이를 통하여 개정된 오염물질 방출 관리기준을 평가하였다. 특히 실란트는 제품마다 완전경화에 소요되는 시간의 편차가 커서 시험기간 내에 완전히 경화되지 않는 제품들도 다수 있는 것으로 나타났다. 그래서 경화시간이 빠른 제품들만 대상으로 개정된 시험방법을 적용하여 실험하였다. 그 결과 개정된 실란트의 관리기준은 기존의 관리기준에 비해 2.5 배 이상 약화된 것으로 나타났다. 개정된 실란트의 시험방법을 모든 실란트 제품에 적용하기 위해서는 시험기간을 연장하거나 실란트 시험편을 빨리 경화시킬 수 있는 시험방법으로 개선이 필요하다.

내화피복을 적용한 강합성보의 구조화재해석 (Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials)

  • 강준원;강문수;윤혜진
    • 한국전산구조공학회논문집
    • /
    • 제36권2호
    • /
    • pp.137-145
    • /
    • 2023
  • 이 논문은 정적 재하상태에 있는 무피복 강합성보와 내화피복을 적용한 강합성보를 대상으로 화재 시 내부 온도 및 수직처짐에 대한 내화피복의 영향을 평가한 결과를 제시한다. 열응력해석을 위한 화재하중으로는 American Society for Testing and Materials E119의 표준화재곡선을 사용했으며, 강재거더 표면에 부착하는 내화재료의 방화효과를 구현하기 위해 외기에서 강합성보로 전달되는 열의 전달계수를 감소시켰다. 실규모 무피복 강합성보에 대한 구조화재실험에서 내부 온도분포와 수직처짐을 측정하였고 실험 결과와의 비교를 통해 비선형 구조화재해석 결과의 타당성을 검증하였다. 내화피복이 적용된 강합성보의 구조화재해석 결과로부터 강재거더 표면에 내화재를 적용할 경우 동일 화재 조건에서 무피복 강합성보에 비해 내부 온도와 수직처짐이 감소함을 알 수 있었다. 또한 열전달계수의 변화에 따른 열응력 응답으로부터 화재 시 강합성보의 온도 및 구조거동에 대한 내화피복의 영향을 제시하였다.

Real Time Road Lane Detection with RANSAC and HSV Color Transformation

  • Kim, Kwang Baek;Song, Doo Heon
    • Journal of information and communication convergence engineering
    • /
    • 제15권3호
    • /
    • pp.187-192
    • /
    • 2017
  • Autonomous driving vehicle research demands complex road and lane understanding such as lane departure warning, adaptive cruise control, lane keeping and centering, lane change and turn assist, and driving under complex road conditions. A fast and robust road lane detection subsystem is a basic but important building block for this type of research. In this paper, we propose a method that performs road lane detection from black box input. The proposed system applies Random Sample Consensus to find the best model of road lanes passing through divided regions of the input image under HSV color model. HSV color model is chosen since it explicitly separates chromaticity and luminosity and the narrower hue distribution greatly assists in later segmentation of the frames by limiting color saturation. The implemented method was successful in lane detection on real world on-board testing, exhibiting 86.21% accuracy with 4.3% standard deviation in real time.

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • 제4권1호
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

HOT-SMOKE TESTS IN TWO UNDERGROUND RAILWAY STATIONS WITH MOVING TRAINS

  • Allan, Hugh
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.472-476
    • /
    • 1997
  • Hot-smoke testing in Australia has progressed to the stage where there is an Australian Standard for these tests. The purpose of such tests is twofold: firstly they can validate computer modeling predictions for smoke movement, and secondly they can demonstrate that the smoke control systems and associated fire safety systems function satisfactorily. Hot-smoke tests were carried out in March 1997 at two of Sydney's underground railway stations, namely St James and Museum. The purpose of the tests was to demonstrate that the smoke control systems performed their functions as intended. Tests were carried out in the concourses and on the platforms, and trains ran during the tests so that the effect of moving trains on smoke movement could be observed. A total of five tests were carried out and video recordings were taken of each. This is the first time that hot-smoke tests have been carried out in an underground station with trains running. The paper discusses some of the interesting observations and the problems identified by the tests.

  • PDF