• 제목/요약/키워드: Standard testing building

검색결과 86건 처리시간 0.023초

합벽구간 및 지하구조물 외벽에 사용되는 방수재료 내진 성능실험방법 (Anti-Seismic Evaluation of Waterproofing Materials for Positive-Side wall and pile wall of Underground Concrete Structures)

  • 오규환;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.210-211
    • /
    • 2021
  • This study introduces and demonstrates the application of an experimental regime for anti-seismic performance evaluation of waterproofing materials to used for concrete pile walls. Concrete pile walls are subject to high degree of seismic load, and the occurring stress can affect the waterproofing integrity of the structure, but there is currently no existing methodology or standard for evaluating this property of waterproofing materials. To propose and conduct this evaluation, a new testing apparatus was designed and manufactured intended to be able to test an installed waterproofing material's seismic resistance performance.

  • PDF

방화용 실런트 성능 평가 방법 연구 (A study for the test method of fire resistance construction sealant)

  • 안명수;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.179-182
    • /
    • 2013
  • Many kinds of fire-stop sealants have been used for joint sealing, cable penetration part sealing and fireproof structure finishing etc in building sectors which need water-proofing and fire-stop properties. But, fire-stop sealant itself has no specific industry standards in Korea even though there are so many required properties for the application. So, in this study, for the evaluation, we adopted and applied UL standard 94(UL 94) which is commonly used for the fire retardant testing in inflammable materials like plastics and rubbers in electronics industry. In this study, we demonstrated fire resistance properties of each fire-stop sealants which varied with different formulation, thickness and origins available in Korea. Overall, fire stop sealant had better fire resistance performance than normal construction sealant. And the thicker the material, the better the fire resistance performance was. Because there is no national or industry guideline for fire stop sealant itself, each sealant products showed different level of performances under UL94 desigation. Even certain product had very poor fire proof propeties although it claims it can be used for the application.

  • PDF

Components of wind -tunnel analysis using force balance test data

  • Ho, T.C. Eric;Jeong, Un Yong;Case, Peter
    • Wind and Structures
    • /
    • 제18권4호
    • /
    • pp.347-373
    • /
    • 2014
  • Since its development in the early 1980's the force balance technique has become a standard method in the efficient determination of structural loads and responses. Its usefulness lies in the simplicity of the physical model, the relatively short records required from the wind tunnel testing and its versatility in the use of the data for different sets of dynamic properties. Its major advantage has been the ability to provide results in a timely manner, assisting the structural engineer to fine-tune their building at an early stage of the structural development. The analysis of the wind tunnel data has evolved from the simple un-coupled system to sophisticated methods that include the correction for non-linear mode shapes, the handling of complex geometry and the handling of simultaneous measurements on multiple force balances for a building group. This paper will review some of the components in the force balance data analysis both in historical perspective and in its current advancement. The basic formulation of the force balance methodology in both frequency and time domains will be presented. This includes all coupling effects and allows the determination of the resultant quantities such as resultant accelerations, as well as various load effects that generally were not considered in earlier force balance analyses. Using a building model test carried out in the wind tunnel as an example case study, the effects of various simplifications and omissions are discussed.

습윤 환경 구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Crack Repairing Material using in Wet Environment Structure)

  • 강효진;우영제;강호경;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.43-48
    • /
    • 2002
  • Since the basement building like the communication hole and etc. is built under the ground where it is pressed by the water, the leakage happens due to the dried-shrinking crack, the sinking crack, the creation of the work-joint of the building and etc. caused by the character of the material and construction way of the reinforced concrete building. Especially, a lot of repair for the leakage cannot help but being taken in temporary way without any noticeable countermeasure. Therefore, this kind of repair is socially criticized many times that this is defective construction even if this costs a lot. The fundamental reason of the above mentioned symptoms can be found in the creation of the work-joint caused by the character of the concrete building, the limitation of the physical performance of the existing water-proof and repair material, the limitation of the construction, the limitation of the physical sustaining performance of the concrete building, the limitation(heat-injury, deterioration) of the constancy of the durability caused by aging and etc. Therefore, in this study, we would like to present the better understanding on the water-proof seal relating to the application at the spot and its test evaluation related data since the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is rising a lot to regulate the water-proof technology and the leakage repair technology in accordance with the growth of the demand on the facility.

  • PDF

그라우팅 주입성능 실내실험 장비 개발 및 신뢰도 평가 (Development and Assessment of Laboratory Testing Apparatus on Grouting Injection Performance)

  • 진현우;유병현;이장근
    • 한국지반환경공학회 논문집
    • /
    • 제17권10호
    • /
    • pp.23-31
    • /
    • 2016
  • 국내 그라우팅은 주로 물과 유사한 점도를 가진 재료를 이용하여 시공되고 있다. 하지만 최근에는 지하공간 및 해저공간 개발이 활발해짐에 따라 미세균열 보강을 위한 고점도의 그라우팅 재료와 고압의 주입압력을 사용하는 그라우팅 시공이 증가하는 추세이다. 따라서 균열 폭, 그라우팅 재료의 점도, 주입압력을 고려하여 그라우팅 재료의 주입성능을 평가할 수 있는 실내실험 기준이 마련되어야 한다. 본 논문에서는 그라우팅 재료가 주입되는 방식인 방사형 흐름과 선형 흐름에 관한 메커니즘을 이론적으로 정리하고, 각각의 흐름을 모사할 수 있는 실내실험 장비를 소개하고 있다. 방사형 흐름은 원형의 아크릴판으로 제작하여 그라우팅 재료가 중심에서 방사형으로 퍼져나가도록 모사하였고, 선형 흐름은 평행한 스테인리스 철판으로 제작하여 그라우팅 재료가 한쪽 방향으로 주입되도록 그라우팅 재료의 주입 메커니즘을 모사하였다. 실내실험 장비는 상판과 하판으로 구성되어 있으며, 이 사이에 다양한 두께의 공업용 필름을 설치하여 현장에서 발생하는 다양한 균열 폭을 모사하였다. 본 연구에서 사용된 주입재료는 재료적 특성인 점도를 고정하기 위해 상온($20^{\circ}C$)에서 1cP로 알려진 물을 사용하여 실내실험 장비의 성능테스트를 수행하였으며, 이 결과를 바탕으로 최적의 그라우팅 재료 주입성능 평가 기법을 소개하고자 한다.

Open-jet boundary-layer processes for aerodynamic testing of low-rise buildings

  • Gol-Zaroudi, Hamzeh;Aly, Aly-Mousaad
    • Wind and Structures
    • /
    • 제25권3호
    • /
    • pp.233-259
    • /
    • 2017
  • Investigations on simulated near-surface atmospheric boundary layer (ABL) in an open-jet facility are carried out by conducting experimental tests on small-scale models of low-rise buildings. The objectives of the current study are: (1) to determine the optimal location of test buildings from the exit of the open-jet facility, and (2) to investigate the scale effect on the aerodynamic pressure characteristics. Based on the results, the newly built open-jet facility is well capable of producing mean wind speed and turbulence profiles representing open-terrain conditions. The results show that the proximity of the test model to the open-jet governs the length of the separation bubble as well as the peak roof pressures. However, test models placed at a horizontal distance of 2.5H (H is height of the wind field) from the exit of the open-jet, with a width that is half the width of the wind field and a length of 1H, have consistent mean and peak pressure coefficients when compared with available results from wind tunnel testing. In addition, testing models with as large as 16% blockage ratio is feasible within the open-jet facility. This reveals the importance of open-jet facilities as a robust tool to alleviate the scale restrictions involved in physical investigations of flow pattern around civil engineering structures. The results and findings of this study are useful for putting forward recommendations and guidelines for testing protocols at open-jet facilities, eventually helping the progress of enhanced standard provisions on the design of low-rise buildings for wind.

콘칼로리미터를 사용한 샌드위치패널 연소특성에 대한 실험적 연구 (The Experimental Study for the Combustion-Property of Sandwich Panels using ISO 5660 Cone Calorimeter)

  • 박수영;김대회;임홍순
    • 한국화재소방학회논문지
    • /
    • 제20권4호
    • /
    • pp.33-41
    • /
    • 2006
  • 국내에서는 현재 샌드위치패널의 화재안전성능 평가를 위하여 KS F 2271(건축물의 내장재료 및 구조의 난연성 시험방법)을 사용하고 있다. 국내와 동일한 시험방법을 사용하고 있던 일본에서는 2000년 건축기준법 개정시 ISO 5660-1 시험방법을 내장재의 연소성능시험으로 채택하였다. 그에 따라 국내에서도 KS F 2271 시험방법을 보완하는 건축법 개정고시(안)을 예고하였고, 그 내용은 ISO 5660-1(Cone Calorimeter Method) 시험방법을 도입하는 것으로 알려져 있다. 본 연구에서는 샌드위치패널의 연소특성을 ISO 5660-1 콘칼로리미터 시험방법을 사용하여 검토하였다. 국내에서 일반적으로 사용되는 4종의 샌드위치패널과 4종의 심재(단열재)의 착화시간, 최대열방출율, 총 열방출량을 검토하였으며, 시험체별 시험결과를 분석하였다. 최종적으로 일본과 NBC개정안에서 제시하는 분류기준에 시험결과를 적용하였다.

무창 기공형 태양열 공기 난방 모듈 성능 모니터링 연구 (Performance Monitoring Study of Unglazed Transpired Solar Air Heating Module)

  • 강은철;현명택;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.67-72
    • /
    • 2002
  • Solar Air Systems (SAS) have unique advantages for space heating and tempering ventilation air. Air, unlike water, needs no protection against freezing nor are leaks damaging to the building structure or its contents. In contrast to glazed collector, unglazed steel solar collector may have higher efficiencies over glazed flat collector due to the absence of the glass. Therefore, the monitoring of SAS is so important to evaluate actual performance of SAS for right applications. This study is to provide a testing method with a movable test cell developed in KIER to evaluate the thermal performance of SAS based on international standard method ASHRAE 93-86, "Method of Testing to Determine the Thermal Performance of Solar Collectors". The monitoring tool used advanced technique LabVIEW 6i with portable notebook computer. Sample results have been obtained to access the performance of a reference and a target SAS module. The process and tool introduced here could be used to provide a performance verification data for future implementation study applications.

항주자세를 고러한 세일링 요트의 선형기법 시험연구 (A Study on the Techniques for Sailing Yacht Model Tests with Sailing Condition)

  • 심상목;김동준;강병윤
    • 대한조선학회논문집
    • /
    • 제43권1호
    • /
    • pp.32-42
    • /
    • 2006
  • This study aims at establishing a technique for sailing yachts model tests with sailing condition. It is very important to estimate a ship's potential speed performance before building a real ship. Several methods are used to estimate a ship's potential speed performance such as using parent ship data, standard vessel chart and model test. Model test is the most precise among these options. In korea. model testing is widely used with general vessels but not with sailing yachts. Because sailing yachts are propelled with heeling and leeway. using the wind. another method is needed to estimate their speed. The new model test. which is different from tests for upright general vessels, is in a great demand. In this paper. we describe a test method for the sailing yacht model test. based on Masuyama's equation of motion. And we describe choosing scale ratio. production process and materials of the model. Also. various ways of measuring instruments. attaching jigs and adjusting calibration are described so that they can be utilized as useful data for model testing.

지하 콘크리트 구조물의 거동에 대한 방수층의 대응성 평가에 관한 실험적 연구 (Performance Test Method on the Influence Waterproofing as Behavior of Concrete Structure)

  • 노종수;권시원;곽규성;권기주;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.77-81
    • /
    • 2004
  • The massive structures are not free to move with vibration, differential settlement, thermal stresses because, construction and expansion joint, crack etc., can be large enough to cause leakage as deformation of waterproofing. It has been depended on the test method of tensile/tear strength which is waterproofing performance as behavior of concrete structure crack. However, not to practically confirm the creep applied to concrete surface, even waterproofing membrane have more performance than definite strength and elasticity. Therefore, in this study will focus on the test method to consider a resistance performance about loose adhesion and deformation of waterproofing and behavior of concrete structure as construction/expansion joint, crack. Performance test method on the influence as behavior of concrete structure crack is to choose waterproofing materials and construction method which possible to confront with behavior of 50mm crack in the atmosphere and low temperature. Examine the deformation of waterproofing membrane and loose adhesion which can occur to structure in general job site, suggest standard testing method to analyze correlation waterproofing membrane and structure with 5-types of materials used in this study, such as Adhesion membrane and sheet complex, sheet and urethane complex, self-adhesive sheet, spray poly-urea, spray membrane of rubberized Asphalt.

  • PDF