• Title/Summary/Keyword: Standard technology

Search Result 10,275, Processing Time 0.039 seconds

Effect of Sawdust Moisture Content and Particle Size on The Fuel Characteristics of Wood Pellet Fabricated with Quercus mongolica, Pinus densiflora and Larix kaempferi Sawdust (신갈나무, 소나무, 낙엽송 목분의 함수율 및 크기가 목재펠릿의 연료적 특성에 미치는 영향)

  • Kim, Seong-ho;Yang, In;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.757-767
    • /
    • 2015
  • This study was conducted to investigate the effects of moisture content and particle size of sawdust on the fuel characteristics of wood pellets produced with Mongolian oak (Quercus mongolica, QUM), red pine (Pinus densiflora, PID) and larch (Larix kaempferi, LAK) sawdust using a flat-die pelletizer. Prior to produce wood pellets, the sawdust was controlled to the moisture content of 8, 11, 12% and was screened to the particle size of 2 and 4 mesh. In the analysis of its chemical composition, QUM had a high ash content, and PID and LAK contained large amount of lignin. In case of the fuel characteristics, PID pellets had the lowest moisture content of pellets (P-MC), and LAR pellets was found to have the highest bilk density (BD) and durability (DU). With the increase of moisture content of sawdust (S-MC), P-MC and DU of QUM, PID and LAK pellets increased, but BD of QUM and LAK pellets decreased. When size of sawdust used for the production of wood pellets decreased, P-MC and BD of LAK pellets and BD of QUM pellets increased. Decrease of particle size contributed to the increase of DU of QUM, PID and LAK pellets. In addition, BD and DU of QUM pellets produced with 12% S-MC sawdust increased as its particle size reduced. For LAK pellets, DU was not influence by particle size in the S-MCs of 10% and 12%, but increased with the decrease of particle size in the S-MC of 8%. Based on the results and economical aspects, 10% MC and 2 mesh paricle size for QUM sawdust and 12% MC and 2 mesh particle size for PID sawdust might be optimal conditions for pellets production, and fuel characteristics of wood pellets produced by the conditions greatly exceeded the minimum requirements for the $1^{st}$-grade wood pellets of the standard designated by Korea Forest Research Institute.

A Study for the Evaluation of Container Modules; The Technology of Korean Container Tree Production Model (한국형 컨테이너 조경수 생산기술로서 컨테이너 모듈의 성능 평가)

  • Jung, Yong-Jo;Lim, Byung-Eul;Oh, Jang-keun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.5
    • /
    • pp.59-67
    • /
    • 2016
  • In landscape design by public institutions, although the costs and species of landscape trees stipulated by the Korean Public Procurement Service(PPS) are generally adhered to, the PPS regulations about planting trees with well-developed rootlets are almost entirely neglected. This study aimed to evaluate the performance of buried container modules, which are a new technology and product in landscape production that is able to reduce the defect rate while complying with regulations. To this end, this study measured rootlet density, rootlet development length, rootlet survival rate on excavation, and impairments of tree growth for 3 months after root pruning, and compared these variables for the container modules with those for trees that underwent root pruning in bare ground, and those that were cultivated in a container above ground. The results were as follows: First, the rootlet density was 88% for the trees in container modules, which was very high. Trees that underwent standard root pruning in bare ground had a somewhat lower density of 64%. Meanwhile, the trees that were cultivated in pots above ground died, invalidating measurement. Second, in terms of rootlet development and rootlet survival rate, the trees in container modules showed a mean length of 10.4cm, and 100% survival rate, indicating that there was no rootlet damage caused by excavation. For the trees that only underwent root pruning in bare ground, the mean length was 25.6cm and the rootlet survival rate was only half that of the trees in container modules, at 56%, demonstrating considerable damage. Rootlet development did not occur at all in the trees grown in pots. Third, the trees in container modules and those that underwent root pruning in bare ground did not show any deaths during the root pruning process, or any impairments such as stunted leaf growth. Conversely, the trees grown in pots nearly all died, and severe impairments of tree growth were observed. As shown by the results above, when we evaluated the performance of buried container modules, they showed the most outstanding performance of the three models tested in this study. The container modules prevent defects by stimulating early rooting in environments that with poor conditions for growth, or in trees that are not suited to the summer environment Therefore, it is expected that they would be an optimal means by which to enable compliance with rules such as the regulation presented by the PPS.

Dual Codec Based Joint Bit Rate Control Scheme for Terrestrial Stereoscopic 3DTV Broadcast (지상파 스테레오스코픽 3DTV 방송을 위한 이종 부호화기 기반 합동 비트율 제어 연구)

  • Chang, Yong-Jun;Kim, Mun-Churl
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.216-225
    • /
    • 2011
  • Following the proliferation of three-dimensional video contents and displays, many terrestrial broadcasting companies have been preparing for stereoscopic 3DTV service. In terrestrial stereoscopic broadcast, it is a difficult task to code and transmit two video sequences while sustaining as high quality as 2DTV broadcast due to the limited bandwidth defined by the existing digital TV standards such as ATSC. Thus, a terrestrial 3DTV broadcasting with a heterogeneous video codec system, where the left image and right images are based on MPEG-2 and H.264/AVC, respectively, is considered in order to achieve both high quality broadcasting service and compatibility for the existing 2DTV viewers. Without significant change in the current terrestrial broadcasting systems, we propose a joint rate control scheme for stereoscopic 3DTV service based on the heterogeneous dual codec systems. The proposed joint rate control scheme applies to the MPEG-2 encoder a quadratic rate-quantization model which is adopted in the H.264/AVC. Then the controller is designed for the sum of the left and right bitstreams to meet the bandwidth requirement of broadcasting standards while the sum of image distortions is minimized by adjusting quantization parameter obtained from the proposed optimization scheme. Besides, we consider a condition on maintaining quality difference between the left and right images around a desired level in the optimization in order to mitigate negative effects on human visual system. Experimental results demonstrate that the proposed bit rate control scheme outperforms the rate control method where each video coding standard uses its own bit rate control algorithm independently in terms of the increase in PSNR by 2.02%, the decrease in the average absolute quality difference by 77.6% and the reduction in the variance of the quality difference by 74.38%.

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

Characteristics of Carcass and Meat Yields of Fattening Pigs by Production Step (비육돈 생산단계에 따른 도체 및 부분육 생산 특성)

  • Kim, J.H.;Park, B.Y.;Yoo, Y.M.;Cho, S.H.;Kim, Y.K.;Lee, J.M.;Yun, H.J.;Kim, K.N.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.793-800
    • /
    • 2002
  • The characteristics of carcass and meat yields of fattening pigs by production steps were investigated with Landrace (LL, n=41), Yorkshire (YY, n=33), and Duroc (DD, n=30), $F_1$ (LY, n=25), the Crossbred of LYD (n=48). Duroc had more weight loss in carcasses weight than that of the other breed(p<0.05). Yorkshire and $F_1$ had higher production weight in retail cut than that of the other pure or crossbred. Carcass from Landrace and $F_1$ were significantly longer in length than the other breed(p<0.05). $F_1$ produced wider carcass than the other breed. Carcass thickness at aitch bone was higher for $F_1$ and Crossbred than the other breed(p<0.05). Landrace, Yorkshire and $F_1$ produced more loin and tenderloin in weight than the other breed (p<0.05). Yorkshire and $F_1$ produced more picnic shoulder when compared to the other breed. The hind legs produced from Yorkshire and $F_1$ were higher in weight and the fore legs produced from the Crossbred were higher in weight. Duroc produced the lowest weight of belly among the breeds. The acceptance level of loin were extremely low for all breed. Landrace had the highest acceptance level for tenderloin. Yorkshire had the highest acceptance level for picnic shoulder and ham when evaluated by export standard of Japan. In conclusion, The introduction of pure breed and establishment of mating steps are necessary to produce highly accepted pork with high acceptance in carcass and meat yields.

Estimation of Environmental Effect and Genetic Parameters for The Carcass Traits in Hanwoo (Korean Cattle) (한우 도체형질의 환경효과 및 유전모수의 추정)

  • Moon, W.G.;Kim, B.W.;Roh, S.H.;Kim, H.S.;Jung, D.J.;Sun, D.W.;Kim, K.N.;Yoon, Y.T.;Jung, J.H.;Jeon, J.T.;Lee, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • This study aims to estimate the genetic parameters for carcass traits on Hanwoo of breeding farmhouses using Animal Products Grading Service’s data of 428,812 cattle from 101 slaughterhouses nationwide from 2000 to 2005. Using carcass traits of carcass weight, eye muscle area, backfat thickness, marbling score, meat color and fat color that greatly influence Hanwoo's grade, the effects of carcass year, carcass season, sex and carcass region were estimated. Based upon carcass traits of carcass weight, eye muscle area, backfat thickness, marbling score and meat color that greatly influence Hanwoo’s grade, the heritabilities and genetic parameters were estimated of 17,578 Hanwoo slaughtered in 2005 with existing herdbook, where EM-REML algorithm was used in estimating genetic parameters. The mean and standard deviation of each carcass trait are 321.42±53.62kg, 76.25±10.43cm2, 9.96± 4.14mm, 3.75±2.00, 4.83±0.48 and 2.99±0.40, for carcass weight, eye muscle area, backfat thickness, marbling score, meat color and fat color, respectively. As a result of analysis on the effects of carcass year, the carcass weight, backfat thickness and meat color came out highest as 359.40±0.181, 9.82±0.017 and 4.90±0.002, respectively in 2004. As a result of analysis on the effects of carcass season, the carcass weight and eye muscle area came out highest as 345.88±0.144 and 79.57±0.033 respectively in spring, and the backfat thickness was highest as 8.78±0.013 in winter, and the meat color and fat color slightly came out higher as 4.88±0.002 and 2.96±0.001 in fall, while the marbling score was highest as 3.29±0.006 in summer. The results of the analysis on the effects of sex indicated that the backfat thickness and fat color were highest as 10.53±0.010 and 3.07±0.001 in cow, the carcass weight came out highest in Hanwoo steer as 368.03±0.068kg, the eye muscle area were highest as 82.96±0.042 in bull, and the marbling score was highest as 4.19±0.007 in steer, and the meat color was highest as 4.89±0.001 in cow. Regarding the results of analysis on the effects of carcass region, the carcass weight, eye muscle area,

A Study on the Bonding Strength, Reactivity and Thermal Properties of Epoxy Resin Mixed with ESBO (에폭시수지-ESBO 혼용 비율에 따른 목재접착제의 접착력, 반응성 및 열분석에 관한 연구)

  • Choi, Jin Lim;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.36-44
    • /
    • 2007
  • The purpose of this study was to investigate thermal stability, reactivity, and bonding strength of existing epoxy resin mixed with the epoxidized soybean oil (ESBO) in order to use soybean oil economically. In the dry shear test, the marked strengths showed $30.5kgf/cm^2$ at the ratio of ESBO to epoxy resin 9 : 1 and $6.2kgf/cm^2$ at the ratio 8 : 2. The bonding strengths of the others, except mixing ratios 2 : 8 and 1 : 9, exceeded the requirement of Korean plywood standard of $7.0kgf/cm^2$. In the wet shear test, the result was $5.8kgf/cm^2$ at the ratio 9 : 1. There were no thickness swelling and moisture absorption in the water resistance of the film. The value of activation energy, Tg (${\Delta}E$), by DSC analysis showed between $110^{\circ}C$ and $120^{\circ}C$ through all ratios. Epoxy in the epoxy resin fully reacted with the hardener (TETA), but it is difficult to decide that epoxys in the ESBO were reacted directly with the hardener from FT-IR analysis. As the mixing ratio of ESBO increased, the thermal stabilities dropped from TGA analysis. From the comprehensive view on the results of above experiments, it could be confirmed through experiments that the ESBO in the mixed adhesive of epoxy resin/ESBO played a role as an extending agent level of epoxy adhesive, and we were able to know that in order to utilize ESBO as an adhesive, a study should be performed on the condition of hardening, inducible of the hardening reaction.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF