• Title/Summary/Keyword: Standard technology

Search Result 10,275, Processing Time 0.037 seconds

Selection of Optimum Filter Media in Small-Scale Livestock Wastewater Treatment Apparatus by Natural Purification Method (자연정화공법을 이용한 소형 축산폐수처리장치의 최적여재 선정)

  • Kim, Ah-Reum;Kim, Hong-Chul;Seo, Dong-Cheol;Park, Jong-Hwan;Kim, Sung-Hun;Lee, Seong-Tae;Jeong, Tae-Uk;Choi, Jeong-Ho;Kim, Hyun-Ook;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.285-292
    • /
    • 2011
  • In order to develop livestock wastewater treatment technology by natural purification method, the optimum filter media in small-scale livestock wastewater treatment apparatus for treating livestock wastewater were studied. Removal rates of pollutants under different filter media were in the other of coarse sand ${\fallingdotseq}$ broken stone > zeolite > calcite for COD, zeolite >> broken stone ${\fallingdotseq}$ coarse sand ${\fallingdotseq}$ calcite for T-N, and calcite > coarse sand ${\fallingdotseq}$ broken stone ${\fallingdotseq}$ zeolite for T-P. Based on the above results, the optimum filter media was coarse sand in small-scale livestock wastewater treatment apparatus. To meet acceptable effluent quality standard for livestock wastewater and to improve T-N and T-P removal efficiencies, removal efficiencies of pollutants in small-scale livestock wastewater treatment apparatus with mixed filter media were studied. The removal rates of COD, SS, T-N and T-P in effluent were 84, 94, 65 and 98% in small-scale livestock wastewater treatment apparatus with mixed filter media, respectively. For increasing the T-N and T-P removals in small-scale livestock wastewater treatment apparatus, the mixed filter media are recommended.

Middle School Home Economics Teachers 'Family Value and Needs on Learning Objectives of Family Life Area according to the Three Systems of Action (중학교 가정과교사의 가족가치관과 세 행동체계별 가족생활 영역 목표 요구도)

  • Oh Yun Hee;Chae Jung Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.17 no.2
    • /
    • pp.239-255
    • /
    • 2005
  • The purpose of this study was to understand middle school Home Economics teachers' family value and needs on learning objectives of family life area, and to identify the relationship between the two. Data was collected from the survey mailed to the teachers responsible for family life area in $\lceil$Technology/Home Economics$\rfloor$ in middle schools in Korea. The collected 312 questionnaires were used for final analysis. SPSS/WIN program was used for calculating average, standard deviation, percentage, t-test, ANOVA with post-verification scheffe., and correlation analysis. Followings are the summary of the results of this study. Firstly, the family value of middle school Home Economics teachers was relatively modern. They had very modem sense of value in all of the sub-areas such as sense of value on marriage. on gender role. on children, on filial love, and familism. Secondly, regarding needs on family life area of learning objects of Home Economics teachers, the requirement on emancipatory system of action was the highest. technical system of action was the next, and Communicative System of Action was the lowest. Thirdly, in the relationship between the needs of teaming objects of family life area and the family value, the needs of technical and interpretive behavioral system had few things to do with the family value. However. the needs on teaming object needs of emancipatory system of action was higher as the family value was modern. The trend in the relationship with needs was same in all the sub-areas such as sense of value on marriage, on gender role, on children. on filial love, and familism. However, the family value and the achievement level of family life area goals did not show significant correlation. Fourthly, regarding the family value and the needs on teaming objectives of family life area of middle school Home Economics teachers, those who were female, who had certificates for Home Economics Teaching, who were young and who had less experiences in teaching had more modem family value and required more teaming objectives in emancipatory system of action. Considering the results of the study, it is needed to emphasize the learning objects of emancipatory system of action in family life education by inducing consensus on the proposition that Home Economics subject is a critical and practical subject. To do this. it is needed to provide Home Economics teachers with emancipatory interest and mature family value through educating and refreshing them. It is desirable to separate Technology and Home Economics so that certificated Home Economics teachers could teach family life area. In that case they can teach the subject in the point of practical criticism. If the area is to be taught by other subject teachers there should be enough understanding on the philosophy and nature of Home Economics subject beforehand.

  • PDF

Analysis of Safety Education Contents of 『Field of home life』 in Technology·Home Economics Textbook developed by the revised curriculum in 2009 (2009 개정 기술·가정 교과서 『가정생활영역』의 안전교육 내용 분석)

  • Kim, Nam Eun
    • Journal of Korean Home Economics Education Association
    • /
    • v.29 no.2
    • /
    • pp.23-39
    • /
    • 2017
  • The Purpose of this study is to present the basic data for selecting and improving the safety education contents which help practically middle school students through analysis of contents of safety education in 'field of home life' of 2009 revised middle school textbooks. The subjects of analysis are 12 types of middle school textbooks: in total 24 books written by 12 publishers in terms of the revised curriculum in 2009. The analysis criteria is developed by the researcher referring to preceding studies regarding safety education based on the seventh safety education standard presented by the Ministry of Education (2015). With such analysis criteria, all words related to the contents of the safety education of analysis criteria were extracted from each textbook, such as words directly mentioned as 'safety', words mean as 'psychological safety' and 'happy life', words related to 'attention', 'note', 'stability' etc. Under the analytic frame of safety education contents according to a home economics textbook, content analysis method was used for producing the frequency and percent of those words. The textbook analysis shows that the number of pages regarding safety education is 336.3 pages, as 9.8% in total 3,412 pages of 12 types of technology and home economics textbooks. As following the analysis of each textbook volume of the proportion in the contents related to safety education, 224.9 pages are on the first volume and 111.9 pages are on the second volume. As grades increase from year one to year three, the proportion of safety education in home economics textbooks is decreased. The highest number of safety education contents unit is 'Self-management of youth' which includes three parts of safety education. In the case of a unit for emphasizing practice, experience and practical exercise such as 'Life of youth' and 'Practice of eco-living', safety education content in the area of 'life safety' are mostly contained. Safety accidents related to the most student experienced, Household accidents (1.4%) and experiment or practice accidents (0.3%) are presented in a low figure. The contents of universal housing and school violence are duplicated on first and second volume of text. The most presented safety education content in the 12 types of textbooks are proper sexual attitude, dietary problems, family conflict and food choice. The least common contents are dangerous drugs, family welfare, internet addiction and industrial accident compensation insurance. As this study is to analyze 12 textbooks developed in 2009 revision curriculum, it is necessary to compare it with the textbook written by the revised curriculum in 2015 and to clarify the contents system of safety education and to avoid duplication of contents. In addition, it is necessary to develop and distribute a safety education program that can support textbooks.

A Study on the Increase of Dental Technicians in Korea and the Regional Distribution of the Korea Dental Technician Association Members (우리나라 치과기공사의 증가현황 및 협회원의 지역별 분포현황 연구)

  • Kwon, Soon-Seog
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.9-34
    • /
    • 2004
  • The present study reviews the license registration status of dental technicians and dentists from 1970 to 2002, the number of technician members of The Korea Dental Technician Association from 1990 to 2003, and the number of dentist members in 2003. It also considers the yearly membership fluctuations, its growth rates, yearly increase/decrease, the rate of dentist to dental technician, regional distribution of association members, regional yearly increase/decrease of the members, and the regional distribution of dentists and dental technicians. The purpose is to identify and predict the problems in the demand/supply of dental technicians and the regional imbalance of manpower distribution. By doing so, this study attempts to propose the appropriate standard for the supply of dental technicians and point out the necessity of making mid- or long-term plans for ensuring the efficiency of manpower supply and balanced regional distribution. The result is as follows: 1. The number of dental technicians and dentists in 2002 has grown 36.79 and 9.27 times from 1970, and 2.20 and 2.05 times from 1990, respectively. It tool 11 years for the twofold increase of dental technicians from 1990, one year faster than the same increase of dentists. The number of dental technicians per a dentist was the lowest in 1972 (0.21 person), and the highest in 2002 (0.86 person). Specifically, the fastest growth was observed for a year from 1983 (0.47 technician per a dentist) to 1984 (0.6). From 1984 to 1986, the ratio grew by 0.1 every year. Summing up the numbers of dentists and dental technicians who passed the national certification examination, this study predicted the number of dental technicians per a dentist to be 0.88 in 2003, and 0.90 in 2004. 2. From 1990 to 2003, the average distribution of dental technician was 71.76% in the metropolitan areas and 28.24% in other smaller regions. The proportion of dental technicians working in the three major cities (Seoul, Busan, and Daegu) was the lowest in 2001 (52.39%) and the highest in 1996 (62.66%). The majority number of dental technicians who practiced in the metropolitan areas (about 70% of the entire population) were in service in the three major cities. 3. Compared with 1990, the number of dental technicians in 2003 grew 2.28 times in the large cities, and 2.05 times in other smaller regions. The yearly growth rate was the highest in 1994 over the previous year: 26.06% in large cities and 17.86% in the other regions. In the large metropolitan cities, the growth rate was the highest in Incheon (5.8 times for 5 years from 1998 to 2003), In the rest of the regions, the increase of dental technicians was the highest in Gyeonggi (6.5 times from 1990 to 2003). 4. In 2003, as much as 73.40% of all the members of the Korea Dental Technician Association were distributed in the large metropolitan cities, and the rest 26.60% were in other smaller regions. Meanwhile, 54.35% of the dentists practiced in the metropolitan cities, and the rest 45.65% were in service at other regions. This result indicates that more dental technicians than dentists are concentrated in large cities. More than half of all the technician members of the Association are distributed in the three major cities (i.e. Seoul, Busan, Daegu). On the other hand, 42.03% of dentist members are in these three cities and 53.97% of them practice in Seoul, Gyeonggi, and Busan. In 2003, the ratio of dentist to dental technician is 1:0.43 in general, while the ratio is 1:0.58 in the metropolitan cities, and 1:0.43 in other regions. In 2003, 33.30% of all the certified dental technicians are the member of the Korea Dental Technician Association, while 66.82% of all the licensed dentists are its members.

  • PDF

Evaluation on Reproducibility of Low-Dose Kidney Scan in Dynamic Kidney Scan (동적신장검사에서 저선량을 사용한 신장검사의 재현성 평가)

  • Lee, Jaesang;Lee, Kyuchan;Lee, Seunghwan;Bae, Seongbok;Park, Jongyeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose Dynamic kidney scan is a typical imaging technique that visualizes kidney function. Reproducibility of dynamic kidney scans has been evaluated by comparing low-dose kidney scans with low-dose radiopharmaceutical and standard dynamic kidney scan. With this comparative study, if reproducibility is superb, the dynamic kidney scan method with reduced radioactivity to patients is to be utilized and radiation exposure to patient is to be reduced. Materials and Methods For gamma camera, Orbiter, SymbiaE (Siemens, Germany) was used. Among patients who had used 370 Mbq (10 mCi) from January of 2013 to February 2014 and other patients who had used 185 Mbq (5 mCi) from March of 2014 to July of 2015 with identical condition, 21 subjects using DTPA and 20 subjects using $MAG_3$, 41 subjects in total, had been selected as subjects for data. From renogram of the result image, frame of the peak point was selected. Then, region of interest of kidney and background had been selected and Kidney to Background Ratio has been calculated for comparison. Results In tests using DTPA, kidney to background ratio when using 370 Mbq was $5.67{\pm}0.8$ at average while it was $5.62{\pm}0.87$ when using 185 Mbq, which didn't show much difference. Also in the tests using $MAG_3$, kidney to background ratio when using 370 Mbq was $14.95{\pm}2.58$ at average and $14.56{\pm}2.02$ in 185 Mbq, which neither showed much difference. In paired sample t-test, p-value was 0.566 in DTPA and 0.363 in $MAG_3$, which confirmed that there was no difference between the groups. Conclusion In identical patients, when dose was decreased from 370 Mbq to 185 Mbq, reproducibility of dynamic kidney scan was proven to be excellent. Low-dose Dynamic kidney scan can achieve results with fine reproducibility without improvement in performance of gamma camera and is expected to reduce radiation exposure to patient.

  • PDF

Establishment of Reference Range of Proinsulin (Proinsulin 참고치 설정에 관한 연구)

  • Nam, Yee Moon;Shin, Yong Hwan;Kim, Ji Young;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 2013
  • Purpose: It is very important to establish the appropriate reference range in the laboratory for preventing mistakes like false positive or false negative. Because the reference range in the laboratory is standard of patient test results interpretation. Proinsulin is precursor hormone of insulin, and the importance is increasing for diagnosing diabetes or insulinoma. Proinsulin reagent used in our laboratory is produced in the USA, and the reference range provided by manufacturer was adapted to our reference range after the validation test. But, it is generally recommend for the every laboratory to establish the their own reference range. So, we decided to re-evaluate the reference range with our patients' test results. Materials and Methods: Among 737 patients who had been to health promotion center in our hospital between Dec. $8^{th}$ 2011 and Dec. $21^{st}$ 2011, 563 patients are chosen with exception of diabetics patients and patients showing abnormal test results in Fasting Glucose, HbA1c, Insulin, and C-peptide. The 563 test results (275 males and 288 females) were classified with three groups(entire, male, female), and analysis of normal distribution was performed with aid of SPSS(version 19.0). Because Each group didn't show normal distribution, the reference range was set from the lowest limit of 2.5% to the highest limit of 97.5% with Percentile method used in non-normal distribution. Results: When evaluation values are sorted in ascending order, the entire range is 4.5~52.0 pM and 5.3~51.9 pM for male and 4.5~52.0 pM for female. The calculated reference range with percentile method shows 6.7~26.5 pM for entire group, 6.8~26.5 pM for male and 6.7~26.5 pM for female, respectively. Conclusion: The reference range provided by reagent manufacturer is 6.4~9.4 pM and the one established in this study is 6.7~26.5 pM. This difference might be caused by racial characteristics between Western people and Koreans. So an ideal reference range can be gotten with normal population visiting to every hospital. Our hospital has been using the newly re-establishing reference range under consultation with the department of endocrinology since Aug. $1^{st}$ 2012.

  • PDF

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Correlation of SUV According to the Body Weight and Body Surface Area in PET/CT Imaging (PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계)

  • Park, Ju-Seon;Do, Yong-Ho;Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.44-47
    • /
    • 2013
  • Purpose: There are several methods of measuring SUV in PET/CT imaging including $SUV_{bw}$ which uses the body weight, $SUV_{bsa}$ which that uses body surface area and $SUV_{lbm}$ which uses lean body mass. Currently, Seoul National University Hospital uses $SUV_{bw}$ method which minimizes the variability. In this study, we compared and analyzed the correlation between $SUV_{bw}$ and $SUV_{bsa}$ according to patients' body mass index. Materials and Methods: Using Biograph mCT40 (Siemens, Germany), we conducted $^{18}F-FDG$ PET/CT imaging on 70 patients (41 males, 29 females; ages $58.04{\pm}12.44$). We classified the patients as underweight (BMI<20), normal weight (20$${\leq_-}$$BMI<25), overweight (25$${\leq_-}$$BMI<30), obese (30$${\leq_-}$$BMI<35) and severely obese (35$${\leq_-}$$BMI) according to the patient's sex, age and BIM. Then, bone, liver and lungs were set as ROI for calculation of maximum values of $SUV_{bw}$ and $SUV_{bsa}$, through Syngo.via VA11A analysis program. Results: Comparing the five groups divided according to the BMI by the standard differences between $SUV_{bw}$ to $SUV_{bsa}$, $SUV_{max}$ was measured to be $0.66{\pm}0.15$, $0.78{\pm}0.35$, $0.77{\pm}0.21$, $1.00{\pm}0.44$, $1.53{\pm}0.38$ for bones in underweight, normal weight, overweight, obese and severely obese groups, respectively. For liver, values of $SUV_{max}$ were $1.64{\pm}0.16$, $2.06{\pm}0.34$, $2.19{\pm}0.21$, $2.52{\pm}0.21$ and $2.74{\pm}0.40$ in the same order. And for lung, values of $SUV_{max}$ were $0.69{\pm}0.33$, $0.54{\pm}0.17$, $0.62{\pm}0.23$, $0.83{\pm0.29}$, $1.03{\pm}0.30$. Conclusion: By comparing and analyzing the differences between $SUV_{bw}$ and $SUV_{bsa}$ in this study, it was found that the differences between $SUV_{bw}$ and $SUV_{bsa}$ increased as patient's BMI increased. Thus, there is room for error in the values of SUV depending on the methods of calculations, and appropriate methods must be applied according to the circumstances in clinical settings.

  • PDF

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF