• Title/Summary/Keyword: Standard size

Search Result 3,317, Processing Time 0.036 seconds

Wavelet Transform Based Image Template Matching for Automatic Component Inspection (자동부품검사를 위한 웨이블렛 변환 기반 영상정합)

  • Cho, Han-Jin;Park, Tae-Hyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.2
    • /
    • pp.225-230
    • /
    • 2009
  • We propose a template matching method for component inspection of SMD assembly system. To discriminate wrong assembled components, the input image of component is matched with its standard image by template matching algorithm. For a fast inspection system, the calculation time of matching algorithm should be reduced. Since the standard images of all components located in a PCB are stored in computer, it is desirable to reduce the memory size of standard image. We apply the discrete wavelet transformation to reduce the image size as well as the calculation time. Only 7% memory of the BMP image is used to discriminate goodness or badness of components assembly. Comparative results are presented to verify the usefulness of the proposed method.

Experimental Study of Droplet Characteristics Related to Electrospray Mode (정전분무모드에 관한 액적특성의 실험적 연구)

  • Kim, Ji Yeop;Lee, Doe Hyun;Cho, Ju Hyung;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.26-35
    • /
    • 2022
  • Electrospray is a method of atomizing fluid using high voltage supply and capable of generating continuous flow and coherent size of droplets. Electrical system and properties of fluids has enabled electrospray to have various spray modes. However, its studies have been confined only in Cone jet, which is more stable and easier to manipulate droplets' size than other spraying modes. Therefore, it is necessary to investigate and compare other spraying modes based on experimental parameters and physical properties of fluids. This research paper identified nine different spray modes. It was found out that Sauter Mean Diameter (SMD) is proportional to flow rate of fluids and maximum difference among spray modes was 1.7 times. On the other hand, SMD standard deviation had low variations on specific flow rates of fluids. Pulsed jet mode recorded the largest SMD standard deviation, while Spindle recorded the lowest.

Standardized Body Type and the Suitability of Figures for the Twenties Women (20대 여성의 표준체형과 인대 적합성에 관한 연구)

  • Koo, Mi-Ji;Lee, Jeong-Im
    • Fashion & Textile Research Journal
    • /
    • v.7 no.6
    • /
    • pp.601-608
    • /
    • 2005
  • This research investigated the present state of the dress forms used by clothing manufacturers and proposed procedure to bring out the standardized body type and figure for women in twenties. The result of questionnaire showed chief pattern maker's thoughts that dress form should be differently made for each age group and should be more reflected the standard body than the idea body. The standardized body type was made from the standardized posture and size which were analyzed from the interquartile range(IQR) of 314 subjects. The standardized size could be verified as for the balanced body shape of twenties through making the standard dress form. The standardized form(S form) was compared with three kinds of forms(A, K and P) for investigating the suitability of forms. K form was very similar to S form, Educational P form and manufacturer's A form had quite big differences from S form at the important areas for making clothing. The side shapes of A, K and P forms showed differences at back bending, neck angle and hip shape from S form. A form was comparatively smooth and flat. This results could be used as the practical standard to improve the suitability of size and shape in the dress forms of manufacturers and educators.

The Numerical Formula Control Modeling Regarding on the Grounding Conductor Size Selecting (접지도체 굵기 산정에 관한 수식제어 모델링)

  • Song, Young-Joo;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.107-116
    • /
    • 2006
  • The international standard to determine grounding conductor size can be applied for a wide range of items because it includes the specific physical characteristics, but it has a problem where the numerical formula is complicated. However the JIS and domestic standard numerical formula are simple but have many constraints. The new grounding conductor size selecting method is necessary in order to solve such problems. Therefore, in this study, we suggested an improved method for selecting the grounding conductor size and simple numerical formula with a numerical formula control modeling. and we verified reliability of paper used case study.

A Research on features of rural Hanok in Jeollanam-do by housing scale -Centered around area of the room depending on shape of the plan- (전라남도 농촌한옥의 규모특성에 관한 연구 -평면 형태에 따른 실별 면적을 중심으로-)

  • Choi, Il;Lee, Chang-Jae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.1
    • /
    • pp.81-88
    • /
    • 2013
  • The recently built rural Hanoks have shown changes in appearances regarding its shape, space and size in the traditional floor plan. This is probably the transformation process to suit the needs of modern residence as new spaces and other factors are considered these days. The purpose of the research is to provide basic data for the innovation and construction of future Hankoks by analyzing the size features of the Hanoks in the rural areas of Jeeollanam-do and changing trends. They were divided into 5 types depending on the shape and the spacing of the living room and kitchen. Then size features per each type were analyzed. From this, it was revealed that there needs to be reasonable development of types in the standard design of Hanok because the size of the rooms is actually bigger than the standard design of Hanok in Jeollanam-do. The composition of the utility rooms should be classified as either domestic space or agricultural workspace considering that this area is rural but there are not enough storage spaces for agricultural machines and materials in most houses as they did not install external storage spaces. Therefore, it was analyzed that the size varies with the changes in the composition of space because of Hankok's similarities in the area of the rooms with typical apartments.

Standards Sizing for Clothing based on Anthropometry Data

  • Lee, Young-Suk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.337-354
    • /
    • 2014
  • Objective: The purpose of this study was to examine the various sizing systems and specified anthropometric data as well as the fit issues used today. Background: A standard sizing system for clothes is a system that is developed based on body shape and size classifications method. To develop an efficient sizing system, we have to classify the database from the majority of the samples. Method: The method of this paper deals with the secular trend of height spanning from 1997 to 2010 along with the morphological feature patterns for Koreans. It also investigates the comparison of the growth pattern between male and female and the body shape classification according to the drop values based on the anthropometric data samples of KATS taken from the 2010 surveys in order to develop and define the new guidelines for the size designation systems of clothes. Results: The results are classified with body size and shape categories according to the drop values by age and sex in order to develop the new guidelines for the size designation systems based on these body dimensions from the analyzed anthropometric database. Conclusion: These new guidelines for the size designation system will eliminate the confusion that currently exists among countries and individual apparel designers. Application: The adopted standards could be used to compare the sizing systems worldwide.

A Basic Study on Establishing the Standard Size for hanbok -Concentrating on Women in Their 20's- (20대 여성한복의 기성복화를 위한 치수규격 연구)

  • 남윤자
    • Journal of the Korean Society of Costume
    • /
    • v.42
    • /
    • pp.127-136
    • /
    • 1999
  • This study purport to establish the size was flexibly receptive to consumers. Sample size was 6555 women in their 20's and 29 variables from the diret anthropometric data were applied to analyze. The preliminary survey was taken from Febraury 10. 1997 to May 23 1997 and the measurement was done from April 14, 1997 to June 10. 1997. Follwing the KS regulations Hanbok were given 3cm intervals each for the bust and hip girth and cm for th height. Size system was presented for the usage of developing the pattern of hanbok by analyzing the result of the regression coefficient and referring to the distribution chart of the back length and the neck to ulnar styloid length. When establishing the standard size for the ready-made Hanbok like Western style clothes it's convenient for both consumer and producer to present both bust girth and height. To enhance the fitting of Chogori we used the flatness ratio of bust as the reference for grouping styles of body. in the case of Chima-\ulcorner해갸 4 brackets are developed. First step was bust girth 78cm height 15cm second was bust girth 5852cm5 height 160cm third was bust girth 82cm height 165cm fourth was bust girth 88cm height 16cm.

  • PDF

A Study on the Shelf Sediments from Korea Strait through Decomposition of Size Curves into Normal Components (입도곡선의 정규성분 분해에 의한 대한해협의 대륙붕 퇴적물 연구)

  • KONG Young Sae;KIM Hee Joon;MIN Geon Hong;LEE Chi Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.3
    • /
    • pp.386-392
    • /
    • 1996
  • A numerical method based on genetic algorithms was introduced to characterize the grain-size distribution more effectively. This technique was proved significant particularly for multimodal size distributions, as was verified for samples from Korea Strait continental shelf. Sediment samples collected from the Korea Strait continental shelf revealed that $96\%$ of the grain-size distributions were multimodal. Therefore, the use of grain-size parameters was not the ideal method. As an alternative method, the decomposition of sue curves into elementary normal component curves was used. Means and standard deviations of 593 decomposed normal components were calculated by a numerical method from 268 size curves of Korea Strait sediments. The mean values of decomposed normal components showed peaks at $1\~3\phi\;and\;7\~9\phi$ size classes. The plot of mean and standard deviation values of the coarse fraction normal components on the map showed a characteristic areal distribution. The characteristic distribution was found to derive from underlying Pleistocene sediment on the basis of sea bottom geologic distribution of the area. The method of decomposition into normal components was found to be more effective than the analysis using traditional grain-size parameters in investigation of multimodal size distribution of Korea Strait shelf sediment.

  • PDF

Estimation of Occupational Health Standard by Relationship between Airborne Lead Concentration by Particle Size and Lead in Blood (공기중 납입자의 크기 특성과 혈액중 납농도와의 관계에 의한 허용농도 측정)

  • Park, Dong-Wook;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.265-271
    • /
    • 1996
  • This study was conducted to investigate distribution of lead particles by operation of industry, to evaluate the effect of particle size on the absorption to workers, and to recommend the Occupational Health Standard for lead. Total lead concentrations in the secondary smelting industry were higher than those in the battery and litharge manufacturing industry. Total lead concentrations in other industries except radiator manufacturing industry exceeded the standard of $50{\mu}g/m^3$. Only radiator manufacturing industry indicated lead concentrations significantly lower than those in other industries(p<0.05). Average blood lead level of workers was $85.1{\mu}g/dl$ in secondary smelting manufacturing, $51.3{\mu}g/dl$ in the battery manufacturing, and below $40{\mu}g/dl$ in the litharge and radiator manufacturing industry. Blood lead levels of workers by industry were significantly different(p<0.05). From relationship between airborne lead concentrations by size and lead in blood, confidence limits of airborne lead concentration equivalent to $40{\mu}g/dl$ of permissible limit in blood, was $147.9-489.8{\mu}g/m^3$ as total lead and $28.8-79.4{\mu}g/m^3$ as ACGIH-RPM. It is recommended that two separate occupational health standards for lead should be established by particle size. Airborne concentration of $150{\mu}g/m^3$ as fatal lead dust and $30{\mu}g/m^3$ as respirable lead dust was recommended.

  • PDF

Type Analysis of Lower Trunk Body for the Slacks Pattern Design of Chinese Middle-Aged Men - Focused on Ningbo City, Zhejiang Province - (중국 중년 남성의 슬랙스 패턴설계를 위한 하반신 체간부 유형분석 - 절강성 영파 지역을 중심으로 -)

  • Shim, Boo-Ja;Suh, Chu-Yeon;Lee, So-Young
    • Journal of Fashion Business
    • /
    • v.12 no.2
    • /
    • pp.87-99
    • /
    • 2008
  • This study aims to classify lower trunk body types of Chinese men in their middle age (30s and 40s) and suggest the standard for them to design slacks pattern. Mollison's relation deviations were used to analyze the direct measurement items in this research compared to those of Size Korea 2004. Though Korean middle-aged men were higher in most items than Chinese counterparts, all items except mid-thigh circumference and side hip length were merely within the range of ${\pm}1\sigma$. According to the results of size classification by absolute values, factor analysis extracted to 2 factors(horizontal size of lower body and vertical size of lower body), and cluster analysis brought about 3 types(type1: tall and thin trunk (36.9%), type 2 : normal height and thick trunk(45.5%), and type 3 : short and normal trunk(17.6%) with some significant differences among them. Also, the results of shape classification by index values, they were extracted 4 factors (waist-hip flatness, waist-hip cross section, vertical waist-groin and hip-surface length) by factor analysis and revealed 3 types(type 1: different waist-hip width, thick, long waist, long upper hip, and short hip-surface length(27.8%), type 2 : different waist-hip width, flat, short upper hip, high hip and groin, and average hip-surface length(29.4%), and type 3: small waist-hip width, thick, average upper hip, and short hip-surface length (42.8%)) with significant differences among them by cluster analysis. The results of standard body types by shape-size combination, 19subjects(10.16%) under these values are regarded as standard body types. Significance was not seen in all items in the t-test results between the total group and the standard group. The latter had lower variation coefficients and smaller individual differences than the former. However, in-depth research is required for generalization since this research is limited to a small number of subjects in Ningbo of Zhejiang.