• 제목/요약/키워드: Standard operating system

Search Result 670, Processing Time 0.033 seconds

Analysis of Medical Errors in Operating Room Nursing using Web;based Error Reporting System (수술 간호업무 중 발생한 의료오류의 분석;웹기반 보고체계를 적용하여)

  • Kim, Myoung-Soo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.3
    • /
    • pp.397-405
    • /
    • 2006
  • Purpose: The purpose of this study was to develop the medical error reporting system and to validate an trait of error in the Operating Room. Methods: Descriptive research design was used. The subjects were 30 nurses with below 5-year-career in a University Hospital. Data was collected from 11, April until 22, April, 2005 using web-based error reporting system. Data was analyzed by mean, standard deviation, $X^{2}-test$ using SPSS WIN 10.0 program. Results: A time of medical error in operating room nursing frequent occurrence was from 12 pm. to 4pm. 'Lack of sterile materials' management' was the best frequent occurrence of medical error in operating room nursing. Conclusion: The findings of this study show that manager of healthcare organization must develop the error reporting system more familiar and ordinary. Afterward, we prevent the repetitive medical errors in nursing care through analyzing of error reporting system.

  • PDF

The Frequency Protection of Distribution System with Photovoltaic System (태양광 연계 계통의 주파수 보호 기준 정립)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yoon, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

Design and Implementation of MOST Network Service over POSIX (차량용 MOST 네트워크를 위한 POSIX 기반의 Network Service 설계 및 구현)

  • Lee, Mu-Youl;Chung, Sung-Moon;Jin, Hyun-Wook
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The automotive industry tries to provide infotainment systems to emerging automobiles. Since the infotainment systems require various peripheral devices and network connectivity, legacy operating systems such as Linux and Windows can be much preferred due to its plentiful device drivers and multimedia applications while the operating systems following OSEK standard are used for automotive electronic control units. Thus it is highly desired that the system software supporting infotainment applications can be portable over different legacy operating systems providing unified programming interfaces. The majority of legacy operating systems support POSIX interfaces for application development. MOST is an automotive network standard for infotainment systems. Network Service defines the protocol stacks for MOST control data, which is essential to implement infotainment applications over MOST. In this paper, we suggest a POSIX-based Network Service so that we can utilize legacy device drivers and applications for automotive infotainment systems. We measure the performance of the POSIX-based Network Service and show that its overhead is not significant.

Design and Implementation of Wrapper to Support POSIX Standards on UbiFOSTM Real-Time Operating System (UbiFOSTM 실시간 운영체제에서 POSIX지원을 위한 래퍼의 설계 및 구현)

  • Song, Ye-Jin;Cho, Moon-Haeng;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.8
    • /
    • pp.31-40
    • /
    • 2007
  • Recently, Embedded systems are different with the past as loading of a simple application program that executed specific functions according to the use and are evolved in the digital convergence integrated multimedia functions and then the complication of the application program is remarkably increased. This application program is combined and evolved with many application program in accordance with the demand of the age. For develope and manage this developing application is necessary standardized interface between developer and manager. POSIX was developed as the standard of the operating system in the standard interface which has the open system structure in computing system, and there is a posix.4 to standard for the system demands the loading of real-time operating system like a digital convergence devices. In this paper, we present the contents of designing and implementing the real-time operating system UbiFOSTM to wrapper for supporting the POSIX.4. Also, Experimental results show that implemented wrapper to application program standardizing POSIX.4 in linux and UbiFOSTM is slight only $3{\sim}9{\mu}s$.

A study on the design and construction of operating room (병원 수술실 설계 및 시공에 관한 연구)

  • Jung, Eul-Kyu;Oh, Jung-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.103-110
    • /
    • 2003
  • In the early 1990's the clean room system was a new trend of the operating room. This is the concept using in seminconductor plants. That is what the space around the operating table so clean as it remove contaminations with circulation of interior air. These articles describe the standard of interior construction and drawing details.

Development & Evaluation of Real-time Ensemble Drought Prediction System (실시간 앙상블 가뭄전망정보 생산 체계 구축 및 평가)

  • Bae, Deg-Hyo;Ahn, Joong-Bae;Kim, Hyun-Kyung;Kim, Heon-Ae;Son, Kyung-Hwan;Cho, Se-Ra;Jung, Ui-Seok
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.113-121
    • /
    • 2013
  • The objective of this study is to develop and evaluate the system to produce the real-time ensemble drought prediction data. Ensemble drought prediction consists of 3 processes (meteorological outlook using the multi-initial conditions, hydrological analysis and drought index calculation) therefore, more processing time and data is required than that of single member. For ensemble drought prediction, data process time is optimized and hardware of existing system is upgraded. Ensemble drought data is estimated for year 2012 and to evaluate the accuracy of drought prediction data by using ROC (Relative Operating Characteristics) analysis. We obtained 5 ensembles as optimal number and predicted drought condition for every tenth day i.e. 5th, 15th and 25th of each month. The drought indices used are SPI (Standard Precipitation Index), SRI (Standard Runoff Index), SSI (Standard Soil moisture Index). Drought conditions were determined based on results obtained for each ensemble member. Overall the results showed higher accuracy using ensemble members as compared to single. The ROC score of SRI and SSI showed significant improvement in drought period however SPI was higher in the demise period. The proposed ensemble drought prediction system can be contributed to drought forecasting techniques in Korea.

A Study on the Operating System of the Architectural Standard Scale of Length(尺度, Korean foot) used in the Hwasong City Wall in the 18th Century (척도운용체계를 통해 본 18세기 화성건축의 건축구성에 관한 연구)

  • Lee, Ho-Rak;Lee, Sang-Hae
    • Journal of architectural history
    • /
    • v.6 no.2 s.12
    • /
    • pp.65-77
    • /
    • 1997
  • The Hwasong City Wall was built for three years(1794-1796), but the real construction term was taken only 28 months. The wall and the buildings on the wall were built simultaneously, and the esttimated construction cost was highly restricted. These conditions were main factors for considering the high efficiency of construction productivity. This study examines these factors that are reflected in the operating system of the architectural standard scale of length, the architectural composition system in the Hwasong City Wall to reduce the construction cost. Through the study, following factors are found. 1.The rule of multiple proportion is found in the relationship between the partition distance, that is, span and the height of the girder which is related to the productivity of ready-made building members. 2.The ruling grade system of scale in the component members is found in the chang-bang(창방, penetration members)

  • PDF

A study of Operational Scenarios for the Wireless Communications Based Train Control System (도시철도용 무선통신기반 열차제어시스템 운영시나리오 연구)

  • Yoon, Yong-Ki;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong;Kim, Yong-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.904-909
    • /
    • 2011
  • The development of train control system shall operate a series of processes like system designing, system production and system performance evaluation as a result of various requirements analysis presented in operation rules, operating guidelines for railway organizations etc, notified by the nation. Therefore, considering operation conditions, operation plan, linkage to railway network etc, the major document like system functional specifications, system development specifications, system test plans etc must be drawn up. In this paper we classify system operating scenarios required to prepare for system standard specification and system performance evaluation report of CBTC system for urban subways supporting unmanned automatic operation, and adjust each of the operating status.

  • PDF

Long Term Stability of Uncertainty Analysis of Light Oil Elow Standard System (장기 안정성을 고려한 경질유 유량표준장치 불확도 평가)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1130-1138
    • /
    • 2005
  • A national standard system for the petroleum field has been developed to calibrate and test the oil flow meters in Korea. The operating system and the uncertainty of the system were evaluated by the peer reviewers of foreign national metrology institutes in 2002. Since the characteristics of the system might be changed by time, the uncertainty of the system is reevaluated with the consideration of the long term stability of the system. It is found that the system has a relative expanded uncertainty of 0.048 $\%$ in the range of $15\~120\;m^3/h$. According to the uncertainty budget, the uncertainties of the fluid density and the final mass measurement, which are temperature dependent, contribute about $94\%$ of the total uncertainty in the oil flow standard system

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.