• Title/Summary/Keyword: Standard of test method

Search Result 2,912, Processing Time 0.035 seconds

The Validation Study of Auto Anlysis Method Combined with Aqua Regia Digestion for Fluorine of Soil (왕수분해와 결합한 자동분석법의 토양 중 불소시험 유효성 연구)

  • Na, Kyung-Ho;Yun, In-Chul;Lee, Jung-Bok
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.5
    • /
    • pp.8-15
    • /
    • 2010
  • The purpose of this research is to check the validation of an auto-analysis method combined with aqua regia digestion apparatus for improvement of water distillation method used as a fluorine test of soil. Fluorine contents of CaO used in the pretreatment course of water distillation method were 120 mg/kg ~ 5,064 mg/kg at the blank test, which was exceeded up to maximum 12.5 times of the soil standard, so it was estimated due to a effect of fluorine existing as impurities of CaO. The recovery test of the same samples indicated that water distillation method and auto-analysis method were 134.5mg/kg and 161.7mg/kg respectively, the recovery ratio of the latter was 16.8% higher than the formal. The validation test of two methods satisfied the standard, but auto analysis method was excellent more than distillation method. Also, auto analysis method could save a analysis time up to maximum 4.7 times by comparison with water distillation method.

An Empirical Evaluation of Test Data Generation Techniques

  • Han, Seung-Hee;Kwon, Yong-Rae
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.274-300
    • /
    • 2008
  • Software testing cost can be reduced if the process of testing is automated. However, the test data generation task is still performed mostly by hand although numerous theoretical works have been proposed to automate the process of generating test data and even commercial test data generators appeared on the market. Despite prolific research reports, few attempts have been made to evaluate and characterize those techniques. Therefore, a lot of works have been proposed to automate the process of generating test data. However, there is no overall evaluation and comparison of these techniques. Evaluation and comparison of existing techniques are useful for choosing appropriate approaches for particular applications, and also provide insights into the strengths and weaknesses of current methods. This paper conducts experiments on four representative test data generation techniques and discusses the experimental results. The results of the experiments show that the genetic algorithm (GA)-based test data generation performs the best. However, there are still some weaknesses in the GA-based method. Therefore, we modify the standard GA-based method to cope with these weaknesses. The experiments are carried out to compare the standard GA-based method and two modified versions of the GA-based method.

Scene Change Detection using the Automated Threshold Estimation Algorithm

  • Ko Kyong-Cheol;Rhee Yang-Won
    • The Journal of Information Systems
    • /
    • v.14 no.3
    • /
    • pp.117-122
    • /
    • 2005
  • This paper presents a method for detecting scene changes in video sequences, in which the $chi^{2}$-test is modified by imposing weights according to NTSC standard. To automatically determine threshold values for scene change detection, the proposed method utilizes the frame differences that are obtained by the weighted $chi^{2}$-test. In the first step, the mean and the standard deviation of the difference values are calculated, and then, we subtract the mean difference value from each difference value. In the next step, the same process is performed on the remained difference values, mean-subtracted frame differences, until the stopping criterion is satisfied. Finally, the threshold value for scene change detection is determined by the proposed automatic threshold estimation algorithm. The proposed method is tested on various video sources and, in the experimental results, it is shown that the proposed method is reliably estimates the thresholds and detects scene changes.

  • PDF

Studies on the evaluation of efficacy of functional cosmetics (I) -Studies on the in vitro SPF test method of sunscreen products

  • Son, Kyung-Hun;Kim, Young-Ok;Lee, Jeong-Pyo;Yang, Seong-Jun;Paek, Ock-Jin;Kim, Won-Hee;Kim, Chong-Kap;Heo, Moon-Young;Choi, Sang-Sook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.404.2-404.2
    • /
    • 2002
  • The present study was undertaken to develop the in vitro sun protection factor(SPF) test method having good correlation with in vivo method using human. 8% homomentyl salicylate. P3 reference standard and commercially available sunscreen products were measured by the in vitro method using SPF 290S analyzer. and the SPFs were compared with the SPFs measured by in vivo test method. In vitro SPFs of 8% HMS and P3 reference standard were 4.59$\pm$0.12 and 14.94$\pm$0.83. (omitted)

  • PDF

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

Evaluation of Efficiency Uncertainty for Three-phase Induction Motor using Finite Element Analysis (유한요소 해석을 이용한 3상 유도전동기의 효율 불확도 평가)

  • Lee, Ho-Hyun;Park, Han-Seok;Jun, Hee-Deuk;Woo, Kyung-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.163-168
    • /
    • 2017
  • This paper presented an evaluation method for the efficiency uncertainty of a three-phase induction motor using finite element analysis. The motor efficiency in the finite element analysis is calculated by the loss separation method as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element analysis and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the finite element analysis is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element analysis is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

Assessment of Potential for Liquefaction in the Large Reclamation Site Using GIS (GIS를 이용한 대규모 매립지반의 액상화발생가능성 평가)

  • Kim, Hong-Taek;Yoo, Si-Dong;Park, Sa-Won;Lee, Hyung-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1512-1519
    • /
    • 2005
  • In this study, the potential for liquefaction in the Incheon international airport was calculated by appling the standard penetration test data and laboratory test data to the modified Seed & Idriss(2001) method. The analysis was performed on the non-plastic silty layer and silty sand layer which within the depth of 20m, below 20 of the standard penetration value(N), and the ground water level. Also, each set of data was mapped by using GIS(geographic information systems) and the factor of safety for the potential for liquefaction was obtained by overlapping those layers. As a result, it was found that there exist potential hazard zone for the liquefaction partially. So, the additional detailed assessments for those are thought to be necessary.

  • PDF

A Study on the Standardization of Performance Test Method for CP Rectifier in Korea (국내 전기방식용 정류기의 성능평가 시험 방법에 대한 표준화 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Lee, Ji-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.253-256
    • /
    • 2002
  • Generally, the owners of the facilities adopt CP(Cathodic Protection) Systems to protect the corrosion accidents previously. The developed countries have secured the standard of CP systems through the various researches and consolidation of the rules. So in the first stage. I had been studied the international standards; JSCE, NACE Standard, ASTM, DNV, Australian Standard etc. and standardized the CP systems about items performance. specifications and so on. In this thesis, I have been studying the results of standardization of performance test methods of CP rectifier to apply in Korea.

  • PDF

Establishing Test Method of Sporicidal activity of Commercial Sterilants (아포살균용 살균소독제 유효성 평가방법 확립)

  • Kim, Hyung-Il;Jeon, Dae-Hoon;Yoon, Hae-Jung;Kwak, In-Shin;Eom, Mi-Ok;Sung, Jun-Hyun;Park, Na-Young;Won, Sun-Ah;Bae, Seo-Young;Lee, Young-Ja;Kim, So-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.312-317
    • /
    • 2009
  • Usually, bacterial spores are hundreds or thousands of times more resistant to chemical sanitizers than are vegetable bacteria. Consequently, it is hard to assess whether a commercial sterilant, containing hydrogen peroxide and peracetic acid as ingredients, has or does not have sporicidal activity under certain conditions using the National Standard Test Method for assessing bactericidal activity against Escherichia coli and Staphylococcus aureus. Hence we established alternative the standard test method and requirements to determine whether they are effective in showing at least reduction of $10^3$ in the number of Bacillus subtilis ATCC 6633 spores under the required test condition for evaluation of sporicidal activity including verification methodology. This standardized method has proved to be suitable for evaluating effectiveness of commercial sterilants and could be used as Standardization Test Method for assessing sporicidal activity.

A Study on the Standardization for Cathodic Protection System and its Testing Method in Korea (국내 전기방식 시스템 및 시험 방법에 대한 표준화 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.663-665
    • /
    • 2001
  • Generally, the owners of the facilities adopt CP(Cathodic Protection) Systems to protect the corrosion accidents previously. The developed countries have secured the standard of CP systems and its test methods through the various researches and consolidation of the rules. So, we have been studying the international standards; JSEC, NACE Standard, ASTM, DNV, Australian Standard etc. and standardizing the systems and its test methods to apply in Korea.

  • PDF