• Title/Summary/Keyword: Standard manual

Search Result 502, Processing Time 0.03 seconds

The Study Of Functional Disability Scales for Low Back Pain (요통의 기능 평가방법에 대한 고찰)

  • Moon, Sang-Hyun;Ryu, Han-Jin;Lee, Jons-Soo;Youn, You-Suk
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.4 no.1
    • /
    • pp.39-53
    • /
    • 2003
  • Objectives : The object is to the difference among the funtional disability scale for low back pain and to use Methods : I researched the contents of funtional disability scale for low back pain Results & Conclusions : 1. The funtional disability scale for low back pain is specific-condition and general-health 2. A proposal of set core of funtional disability scale for low back pain is back specific function, generic health state, pain, work disability, satisfaction 3. Oswestry disability index or Rolland disability questionnaire. wase used for standard specific-condition scale and SF-36 was used for standard general-health scale 4. SF-36 is able to use the funtional disability scale for low back pain independence 5. In the future, scale for low back pain shulod be standardized in multiple dimension by computer

  • PDF

The Survey for Environmental Management of Korea Detector Dog (국내 탐지견의 환경 및 위생 관리 현황 조사)

  • Lee, Eun-Chae;Jeong, Ha-Jeong;Hwang, Seong-Gu;Lee, Sang-Rak
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.177-182
    • /
    • 2014
  • This research was conducted to grasp the present condition of environmental management relating to Korea detector dogs that performed their duties such as detection and lifesaving. We directly conducted a survey throughout visit to five government agencies. In environmental management case, average length and width of kennels were 1.78 m and 3.50 m, respectively. Types of floor were searched as coating cement, tile, ucrete and concrete. Most of government agencies ventilated kennels using ventilation fan systems with natural ventilation. But there were differences between government agencies in frequencies of the sanitary management items. On the other side, major diseases of the German shepherd breed as a major detector dog were in order of arthritis, measles, earache, and dermatosis. And their daily training time was average 4 hours. Finally, it is thought that these results could be used as a basic data of standard breeding management manual of Korea detector dog.

Repeatability Test for the Asymmetry Measurement of Human Appearance using General-purpose Depth Cameras (범용 깊이 카메라를 이용한 인체 외형 비대칭 측정의 반복성 평가)

  • Jang, Jun-Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.184-189
    • /
    • 2016
  • Human appearance analysis is an important part of both eastern and western medicine fields, such as Sasang constitutional medicine, rehabilitation medicine, dental medicine, and etc. By the rapid growing of depth camera technology, 3D measuring becomes popular in many applications including medical area. In this study, the possibility of using depth cameras in asymmetry analysis of human appearance is examined. We introduce the development of 3D measurement system using 2 Microsoft Kinect depth cameras and fully automated asymmetry analysis algorithms based on computer vision technology. We compare the proposed automated method to the manual method, which is usually used in asymmetry analysis. As a measure of repeatability, standard deviations of asymmetry indices are examined by 10 times repeated experiments. Experimental results show that the standard deviation of the automated method (1.00mm for face, 1.22mm for body) is better than that of the manual method (2.06mm for face, 3.44mm for body) for the same 3D measurement. We conclude that the automated method using depth cameras can be successfully applicable to practical asymmetry analysis and contribute to reliable human appearance analysis.

Recent Progress of the DUPIC Fuel Fabrication in Korea

  • Lee, J.W.;Kim, W.K.;Lee, Jae-W.;Park, G.I.;YANG, M.S.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.170-181
    • /
    • 2004
  • DUPIC powder and pellets were successfully fabricated in accordance with the quality assurance program described in the Quality Assurance Manual for DUPIC fuel fabrication, which was developed on the basis of the CAN3-Z299.2-85 standard. This manual describes the quality management system applicable to the activities performed for DUPIC fuel fabrication. It covers the work processes, policies and procedures used for planning, executing, and verifying the work carried out for DUPIC fuel fabrication. It is important that a Quality Program is in place before the fabrication of the fuel for irradiation testing. In order to qualify the DUPIC pellet manufacturing processes, 3 series of experiments for the pre-qualification and 3 series for the qualification were performed. In these experiments, the optimum process conditions were established. Then, under the control of the QA program, 8 series of production runs were performed to make the qualified DUPIC pellets in a batch size of 1 kg. In these production runs, DUPIC fuel pellets satisfying the standard CANDU fuel pellet specifications could be successfully produced.

  • PDF

A Study on the Structure of Time Unit and SIMO of MODAPTS and Development of High Task MODAPTS(HITMAT) (MODAPTS의 시간단위 및 동시동작의 구조와 High Task MODAPTS(HITMAP)의 개발에 관한 연구)

  • Park, Seong-Hak
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.137-142
    • /
    • 1992
  • MODAPTS has been widely used for establishing the standard time of manual works because of easy application of the system. However this system was developed based on MTM, winch was one of the low task standard. Also in this system, it usually becomes a cause of error in accuracy that all the simultaneous motions(SIMO) should be analyzed in the sequent motions of two hands. In order to improve the weak points of MODAPTS, the structure of time unit and SIMO of MODAPTS was researched, and HITMAP was developed on the basis of Work Factor System which was one of the high task standard. HITMAP is composed of 26 standard elements and it's time unit is MD(1MD=0.1 second) and MGSRMPS is the motion pattern of HITMAP. In this study HITMAP shows more than 95% of accuracy to WF. Therefor, it is expected that HITMAP can be used for the improvement of productivity and incentive systems.

  • PDF

High Quality Tissue Miniarray Technique Using a Conventional TV/Radio Telescopic Antenna

  • Elkablawy, Mohamed A.;Albasri, Abdulkader M.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1129-1133
    • /
    • 2015
  • Background: The tissue microarray (TMA) is widely accepted as a fast and cost-effective research tool for in situ tissue analysis in modern pathology. However, the current automated and manual TMA techniques have some drawbacks restricting their productivity. Our study aimed to introduce an improved manual tissue miniarray (TmA) technique that is simple and readily applicable to a broad range of tissue samples. Materials and Methods: In this study, a conventional TV/radio telescopic antenna was used to punch tissue cores manually from donor paraffin embedded tissue blocks which were pre-incubated at $40^{\circ}C$. The cores were manually transferred, organized and attached to a standard block mould, and filled with liquid paraffin to construct TmA blocks without any use of recipient paraffin blocks. Results: By using a conventional TV/radio antenna, it was possible to construct TmA paraffin blocks with variable formats of array size and number ($2-mm{\times}42$, $2.5-mm{\times}30$, $3-mm{\times}24$, $4-mm{\times}20$ and $5-mm{\times}12$ cores). Up to $2-mm{\times}84$ cores could be mounted and stained on a standard microscopic slide by cutting two sections from two different blocks and mounting them beside each other. The technique was simple and caused minimal damage to the donor blocks. H&E and immunostained slides showed well-defined tissue morphology and array configuration. Conclusions: This technique is easy to reproduce, quick, inexpensive and creates uniform blocks with abundant tissues without specialized equipment. It was found to improve the stability of the cores within the paraffin block and facilitated no losses during cutting and immunostaining.

Scale Space Filtering based Parameters Estimation for Image Region Segmentation (영상 영역 분할을 위한 스케일 스페이스 필터링 기반 파라미터 추정)

  • Im, Jee-Young;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.2
    • /
    • pp.21-28
    • /
    • 1996
  • The nature of complexity of medical images makes them difficult to segment using standard techniques. Therefore the usual approaches to segment images continue to predominantly involve manual interaction. But it tediously consumes a good deal of time and efforts of the experts. Hereby a nonmanual parameters estimation which can replace the manual interaction is needed to solve the problem of redundant manual works for an image segmentation. This paper attempts to estimate parameters for an image region segmentation using Scale Space Filtering. This attempt results in estimating the number of regions, their boundary and each representatives to be segmented 2-dimensionally and 3-dimensionally. Using this algorithm, we may diminish the problem of wasted time and efforts for finding prerequisite segmentation parameters, and lead the relatively reasonable result of region segmentation.

  • PDF

Pelvic Twist Analysis, PTA (골반 뒤틀림 변위 분석법에 대한 소고)

  • Jo, Jong-Jin;Kim, Sang-Deok
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.5 no.1
    • /
    • pp.135-139
    • /
    • 2004
  • Objectives : The objectives of this report is to introduce PTA. Methods : The examination of the leg length inequality gives us a useful tool for diagnosis of body imbalance. especially pelvic distortion. There are four steps in the process of the leg analysis, according to "The Standard Manual of Chuna Society (2nd ed., Seoul:KCA Press. 2001)". In the last step of the analysis, knee-flexing over $90^{\circ}$, we have often experienced a specific sign that the lower legs are attracted toward one side spontaneously. The authors call it 'Lower Leg Lateral Attraction'. This is a very significant sign that gives us which is the major part between pelvis and the upper parts over sacrum. Thus it is definded as "Pelvic Twist Analysis, PTA" by the authors. With PTA, first, you must check the side of short leg and next, check the side of lateral attraction in lower leg over-flexing. If both sides coincide with each other, then the major part you can correct first is pelvic distortion. If not, you must find another part for primary correction, instead of pelvis. Conclusions : PTA becomes a useful complement to the examination of the leg length inequality.

  • PDF

Evaluation of DNA Extraction Methods from Low Copy Number (LCN) DNA Samples for Forensic DNA Typing

  • Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.15 no.3
    • /
    • pp.229-232
    • /
    • 2009
  • DNA isolation for PCR-based short tandem repeat (STR) analysis is essential to recover high yields of amplifiable DNA from low copy number (LCN) DNA samples. There are different methods developed for DNA extraction from the small bloodstain and gloves, commonly found at crime scenes. In order to obtain STR profiles from LCN DNA samples, DNA extraction protocols, namely the automated $iPrep^{TM}$ $ChargeSwitch^{(R)}$ method, the automated $QIAcube^{TM}$ method, the automated $Maxwell^{(R)}$ 16 DNA $IQ^{TM}$ Resin method, and the manual $QIAamp^{(R)}$ DNA Micro Kit method, were evaluated. Extracted DNA was quantified by the $Quantifiler^{TM}$ Human DNA Quantification Kit and DNA profiled by $AmpFISTR^{(R)}$ $Identifiler^{(R)}$ Kit. Results were compared based on the amount of DNA obtained and the completeness of the STR profiles produced. The automated $iPrep^{TM}$ $ChargeSwitch^{(R)}$ and $QIAcube^{TM}$ methoas produced reproducible DNA of sufficient quantity and quality trom the dried blood spot. This two automated methods showed a quantity and quality comparable to those of the forensic manual standard protocols normally used in our laboratory. In our hands, the automated DNA extraction method is another obvious choice when the forensic case sample available is bloodstain. The findings of this study indicate that the manual simple modified $QIAamp^{(R)}$ DNA Micro Kit method is best method to recover high yields of amplifiable DNA from the numerous potential sources of LCN DNA samples.

  • PDF

Indication Analysis Study through Literature Review of Clinical Trials on Visceral Chuna Manipulation (내장기추나요법 임상연구 문헌고찰을 통한 적응증 분석 연구)

  • Sul, Jae-Uk;Lee, Jin-Hyun;Jo, Dong Chan;Hwang, Man-Suk
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.16 no.2
    • /
    • pp.107-116
    • /
    • 2021
  • Objectives The purpose of this study is to analyze the trend and indication of clinical research about Visceral Chuna Manipulation and to suggest the direction of further study. Methods We searched 9 electronic databases (MEDLINE Pubmed, EMBASE, CENTRAL, CiNii, CNKI, KMbase, OASIS, NDSL, KISS) using the search terms "visceral manipulation", "visceral manual therapy" and identified relevant literature that investigated visceral manipulation as a intervention for various subjects. Results Among 142 studies were searched and screened, 16 met designated criteria. Visceral Chuna Manipulation showed the effectiveness in musculoskeletal disease, digestive disease, psychiatry, obstetrics, circulatory and oncology. Conclusions This study shows possibility of Visceral Chuna Manipulation as a treatment for many diseases. Better designed further study is necessary to establish the evidence of clinical efficacy of visceral manipulation and to suggest standard of techniques and treatment protocols for diverse patients.