• Title/Summary/Keyword: Standard loading test

Search Result 264, Processing Time 0.027 seconds

Regarding a Shear Strengthening of an Epoxy Mortar Panel for RC Beam Without Shear Strengthening Reinforcing Bar (전단보강철근이 없는 RC보에 대한 에폭시 모르타르 패널의 전단보강에 관한 연구)

  • Lee, Sang-Ho;Cho, Min-Su;Heo, Jae-Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.135-146
    • /
    • 2008
  • In this study, the effect of epoxy mortar panel as the shear strengthening material of reinforced concrete beam is investigated by loading test. The main variables are the kind of strengthening material, the amount of reinforcement and the spacing of CFS(Carbon Fiber Sheet) stirrups. The design method to use epoxy mortar panel as shear strengthening of reinforced concrete beam took the shear capacity as the form of the sum of $V_c$, $V_s$, $V_{sheet}$ and $V_p$. By making a comparison between the values calculated by the proposed shear strength prediction formula and those from the loading test results, the mean value was 1.10 and the standard deviation was 8.16%.

Seismic Response of Concrete Walls with Steel Boundary Elements (강재 경계요소를 갖는 콘크리트 벽체의 내진 성능)

  • 조순호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.290-297
    • /
    • 2000
  • A new form of construction utilizing structural steel as the boundary elements in ductile flexural concrete walls is proposed to solve the bar congestion problems associated with such a heavily reinforced region. Two wall specimens containing rectangular hollow structural sections(HSS) and channels at their ends respectively were constructed rectangular hollow structural sections(HSS) and channels ar their ends respectively were constructed and tested under reversed cyclic loading to evaluate the construction process as well as the structural performance. One companion standard reinforced concrete wall specimen was also tested for the comparison purpose At an Initial stage all three specimens were carefully detailed to have the approximately same flexural capacity. Analysis and comparison of test results indicated that the reversed cyclic responses of the three walls showed similar hysteretic properties but in those with steel boundaries local bucking of the corresponding steel elements following significant yielding of structural steel was prominent. Design procedures considering local instability of the structural steel elements and the interaction between steel chord and concrete web members in such composite walls are presented.

  • PDF

Development of the Modified Seismic Coefficient Method to Establish Seismic Design Criteria of Buried Box Structures. (BOX 형 지하구조물의 내진설계 기준 확립을 위한 해석기법개발)

  • 박성우
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.194-201
    • /
    • 2000
  • In this study the modified seismic coefficient method for seismic analysis of buried box structures is developed for practical purpose. The loading coefficient in the modified seismic coefficient method is determined from the results of the response displacement analysis. In the developed method adequate velocity response spectrum in accordance with soil condition is also needed to seismic design of buried box structures, In order to investigate applicability of the modified seismic coefficient method various analyses are performed with different parameters such as depth of base rock height and width of box buried depth and value of standard penetration test. Results from the modified seismic coefficient method are compared with those of the response displacement method in terms of the maximum bending moment and the location of it. From the comparison it is shown that the feasibility of the modified seismic coefficient method for seismic analysis of buried box structures.

  • PDF

A Study of Fatigue Load for Rotor Blades of the Utility Helicopter (다목적 헬리콥터 로터 블레이드 피로하중에 대한 연구)

  • Oh, Man-Seok;Kim, Hyun-Duk;Park, Jung-Sun;Gi, Yeong-Jung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.648-653
    • /
    • 2007
  • In this study, we have generated fatigue load spectrum that is using to prediction of life time for the helicopter rotor blades. We derive utility helicopter missions for the sake of generating load spectrum. Helix and Felix are standard loading sequences which relate to the main rotors of helicopters with articulated and semi-rigid rotors respectively. We got scale factors which is applied to specific case and it did be obtained through the finite element analysis tools. The fatigue life of the rotor blade is estimated by using MSC/Fatigue. We suggest that generated our fatigue load spectrum in conjunction with small utility helicopter should use to rotor blade fatigue test of the korea helicopter program.

  • PDF

Evaluation of Post-earthquake Seismic Capacity of Reinforced Concrete Buildings suffering from earthquakes (지진피해를 받은 철근콘크리트 건물의 잔존내진성능평가)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.105-108
    • /
    • 2005
  • In damage investigation of building structures suffering from earthquake, estimation of residual seismic capacity is essential in order to access the safety of the building against aftershocks and to judge the necessity of repair and restoration. It has been proposed that an evaluation method for post-earthquake seismic capacity of reinforced concrete buildings based. on the residual energy dissipation capacity (the residual seismic capacity ratio )in lateral force-displacement curve of structural members. The proposed method was adopted in the Japanese 'Damage Level Classification Standard' revised in 200l. To evaluate the residual seismic capacity of RC column, experimental tests with positive and negative cyclic loading was carried out using RC building column specimen. Parameters used by the experiment are deformability and member proportion. From the test results, it is appropriated that the residual seismic capacity of RC buildings damaged by earthquakes is evaluated using the method in the Guideline.

  • PDF

Performance Assessment of High Strength Concrete Members subjected to Fire (화재피해를 입은 고강도 콘크리트 구조부재의 성능평가)

  • Choi, Eun-Gyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.487-488
    • /
    • 2010
  • This is the experimental and analysis study on the thermal distribution, structural behavior and residual strength of high strength concrete members subjected to fire. The parameters are strength of concrete, cover thickness, loading state and exposure time to fire. The ISO 834 standard fire curve is used to test. The material and structural property of concrete at high temperature are proposed, also.

  • PDF

A Benchmark Study of Design Codes on Offshore Pipeline Collapse for Ultra-Deepwater

  • Choi Han-Suk
    • Journal of Ship and Ocean Technology
    • /
    • v.10 no.1
    • /
    • pp.38-46
    • /
    • 2006
  • The objective of this paper is to summarize current ultra-deepwater (i.e., up to 3,500 meters water depth) pipeline mechanical design methodologies as part of the limit state design. The standard mechanical design for ultra-deepwater pipelines in the Gulf of Mexico (GOM) is based on API RP 1111. API code also has been used for deepwater projects in west Africa. DNV code OS-F101 was mostly used for deepwater projects in offshore Brazil and Europe. Some pipeline designs in the GOM have started to incorporate parts of the DNV design methodology. A discussion of failure under collapse only and combined loading (i.e. pressure + bending) is presented. The best design criteria are obtained from physical full-scale collapse testing. The comparison of the physical test data and collapse calculations using the DNV and API codes will be presented. It was found that the conservatism still exists in the collapse prediction for ultra-deepwater pipeline using modem design codes such as DNV OS-F101 and API RP 1111.

A Study on Seismic Performance of Spiral Prer (나선철근교각의 내진성능에 관한 연구)

  • 배성용;김광수;이형준;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.363-368
    • /
    • 2000
  • The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. However, The current seismic design requirements for bridges are based on the USA seismic codes for sever earthquake. This provides the basic factors that affects the performance of spiral reinforced concrete piers for seismic loading, and The specimen tests are performed based on load-displacement, effective stiffness and displacement ductility, etc. The quasi-static test was adopted in order to investigate seismic performance of the spiral reinforced concrete pier specimens which had different transverse steel amount, spacing and longitudinal steel ratio under different axial load levels. This study is concluded that seismic design for transverse reinforcement content of spiral reinforced concrete column has influenced on axial load and effective stiffness etc.

  • PDF

Study on Characteristics of Soil Compaction using Accelerometer (진동가속도계를 이용한 지반다짐 특성 연구)

  • Chae, Kwang-Seok;Shin, Dong-Hoon;Im, Eun_Sang;Gu, Ja-Duck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1397-1403
    • /
    • 2008
  • Soil compaction works are essential to construction of dams, breakwaters and roads in order to avoid unexpected settlement/deformation of superstructures. Taking advantage of oscillating accelerometer, this research was made to complement existing methods for assessment of soil stiffness. In order to examine the validity of compaction-degree suggested in the study, tests on vibration characteristics using accelerometers was also performed. Test results for sand and gravel mixtures and Korean standard sands were compared and evaluated by conventional assessment methods under varying conditions as of input frequency, size of loading plate and relative density.

  • PDF

Stress and Thermal Analyses of Pressure Housing of SMART CEDM (SMART제어봉구동장치의 압력용기에 대한 응력 및 열해석)

  • 조대희;유제용;김지호;김종인
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.343-350
    • /
    • 2002
  • The structural stability of pressure housing of SMART CEDM forming pressure boundary must be evaluated. In this paper, the stress and thermal analyses of the upper pressure housing of CEDM are performed for design pressure, hydraulic test pressure and thermal loading. Finite element and boundary condition were generated from the model which is made by I-DEAS program and the stress and thermal analyses were performed by ANSYS Program. The upper Pressure housing was analysed using 2D axisymmetric model because it is symmetry about an axis. The stress values obtained by analysis were compared with the stress intensity limit of ASME and KEPIC MNB standard.

  • PDF