• Title/Summary/Keyword: Standard evaluation

Search Result 5,518, Processing Time 0.044 seconds

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Evaluation of Shear Bond Strength and Adhesive Bond Durability of Mixed Species Structural Glued Laminated Timber (이수종 구조용집성재의 전단접착력 및 접착내구성 평가)

  • Shim, Sangro;Yeo, Hwanmyeong;Shim, Kugbo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.1 s.129
    • /
    • pp.87-96
    • /
    • 2005
  • This study was carried out to evaluate the shear bond strength and adhesive bond durability of structural glued laminated timber (glulam) manufactured with mixed species lumber of Korean red pine, Korean pine and Japanese larch, using resorcinol adhesive and water-based polymeric-isocyanate adhesive (WPI). Each board used as a glulam lamina was graded by visual inspection. The visual lumber grade of the all species was very low due to the large size and number of knots and the steep slope of grain. In view of the results, appropriate pruning, sawing and drying processes might be needed to produce high grade lamina lumber with small knot size and drying defect free. Shear bond strength of every tested glulam specimen ranged between 7.9 and $9.9N/mm^2$, and much higher than the Korean Standard (KS) for glulam shear bond strength, $7.1N/mm^2$. There was not much shear bond strength difference between wood/resorcinol and wood/WPI. The resorcinol adhesive bond durability exceeded KS requirements. However, delamination on the end-grain surfaces of WPI glulam submerged in both room temperature and boiling water severely occurred, and its durability did not meet KS requirements. Further investigations may be required, and special care should be taken, to ensure long service life of WPI glulam used for exterior application. Results of this study are expected to be useful for improvement of mechanical properties and structural performance of mixed species glulam.

Performance Ranges of the Neurobehavioral Core Test Battery among Female Workers Occupationally Not Exposed to Neurotoxic Agents in Manufacturing Industries (신경독성 물질에 폭로되지 않은 제조업체 여성 근로자의 신경행동검사 수행능력범위)

  • Lee, Kyung-Jae;Lee, Se-Hoon;Kim, Hyoung-Ah;Lee, Won-Chul;Chang, Seong-Sil;Park, Chung-Yill;Chung, Chee-Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.911-923
    • /
    • 1995
  • With increased use of neurotoxic agents in manufacturing industries, hazardous effects of neurotoxic agents pose significant problems in protecting health of workers who work in these industries. A normal range of neurobehavioral performance is required to study hazardous effects of neurotoxic agents among workers. However, such reference for Korean population is not available yet. The objective of this study is to estimate a normal range of neurobehavioral test performance of female workers in Korea. Data for neurobehavioral test performance developed by the World Health Organization were obtained from 165 female workers. Study subjects, 140 production workers and 25 clerks, who voluntarily participated in this study were not occupationally exposed to neurotoxic agents. The mean age and the mean education years of them were 32 years and 10.9 years, respectively Santa Ana dexterity, pursuit aiming, digit symbol, simple reaction time, and Benton visual retention tests among the Neurobehavioral Core Test Battery(NCTB) were included in the evaluation. Subjects were interviewed by a trained interviewer for their detailed occupational history $Mean({\pm}SD)$ performance of the participants were: $45.7{\pm}7.1\;and\;41.9{\pm}6.4$ in the Santa Ana dexterity test of the preferred and non-preferred hands; $45.7{\pm}7.1\;and\;41.9{\pm}6.4$ in correct dot of the pursuit aiming test; $57.7{\pm}16.0$ in the digit symbol test; $274.8{\pm}44.6$ msec in the mean simple reaction time and $70.5{\pm}69.0$ msec in the mean standard deviation of it; and $7.8{\pm}1.7$ in the Benton visual retention test. Most neurobehavioral performance scores were correlated significantly with age and educational level. Educational level was found to be a significant independent variable which was associated with all test scores. Age was significantly associated with scores of pursuit aiming and digit symbol tests.

  • PDF

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

Selection and Quality Evaluation of Sprout Soybean [Glycine max (L.) Merrill] Variety for Environment-Friendly Cultivation in Southern Paddy Field (남부지역 친환경 논 재배를 위한 나물콩 품종 선발 및 품질 평가)

  • Kim, Young-Jin;Lee, Kwang-Won;Cho, Sang-Kyun;Oh, Young-Jin;Shin, Sang-Ouk;Paik, Chae-Hoon;Kim, Kyong-Ho;Kim, Tae-Soo;Kim, Ki-Jong
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.3
    • /
    • pp.357-372
    • /
    • 2011
  • We carried out the experiment to select the suitable sprout soybean varieties for environment-friendly cultivation in paddy field of southern part area, compares of excess moisture injury degree and yield ability among 29 sprout soybean varieties. Plant growth of sprout soybean was generally low in beginning and recovered after flowering due to rainfall. In paddy field cultivation, number of pod per individual and number of seed per individual were less in difference than upland cultivation, and maturing date was delayed 5-14 days than upland cultivation in most species. When environment-friendly cultivation, pest injury was not caused major problem for the growth during the vegetative period of soybean due to ground spider as natural enemy to insect pest. However, damage of stink bugs showed severe during grain filling period, and Dawonkong, Anpyeongkong, Dachaekong and Wonhwangkong showed susceptible to sting bug. SMV infection was weak and showed some necrosis symptoms in Sokangkong, but black root rot was not infected at all. Bacterial pustule began to be infected slowly from pod enlargement stage in most species, displayed severe symptoms in Dawonkong, Pungsannamulkong, Seonamkong and Sobaeknamulkong. The symptoms of pod anthracnose, pod blight and purple spot were greatly appeared after flowering. Disease resistance varieties was Paldokong, Kwangankong, Doremikong, Somyeongkong, Pungsannamulkong, Iksa-namulkong, Seonamkong, Sojinkong, Pureunkong, Bosugkong, Namhaekong and Sorokkong. Lodging index showed 3 in Saebyeolkong, and other species displayed slight lodging in 0-3 degree. 100-seed weight is 9.8-17.2g extent and increased 0.1-3.7g than upland cultivation in most species, but decreased in some species. Government purchase standard, species correspond to small-seed-size namulkong (Sizing screen diameter 4.0-5.6 mm) was Dawonkong, Dachaekong, Bosugkong, Seonamkong, Sokangkong, Hannamkong, Somyeongkong and Wonhwangkong. Species which seed yield was higher than Pungsannamulkong (266kg/10a) were Sorokkong, Hannamkong, Bosugkong and Sowonkong. Considering sprout soybean species, disease endurance, insect resistance, lodging resistance, 100-seed weight, yield ability and excess moisture tolerances synthetically, Seonamkong, Hannamkong, Doremikong, Bosugkong, Pungwonkong, Kwangankong, Sowonkong, Dagikong, Paldokong, Eunhakong and Pungsannamulkong were promising for environment-friendly cultivation in paddy field.

Possibility Estimating of Unaccessible Area on 1/5,000 Digital Topographic Mapping Using PLEIADES Images (PLEIADES 영상을 활용한 비접근지역의 1/5,000 수치지형도 제작 가능성 평가)

  • Shin, Jin Kyu;Lee, Young Jin;Choi, Hae Jin;Lee, Jun Hyuk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.299-309
    • /
    • 2014
  • This paper evaluated the possibility for 1/5,000 digital topographic mapping by using PLEIADES images of 0.5m GSD(Ground Sampling Distance) resolution that has recently launched. Those results of check points by applying the initial RPC(Rational Polynomial Coefficient) of PLEIADES images came out as; RMSE of those were $X={\pm}1.806m$, $Y={\pm}2.132m$, $Z={\pm}1.973m$. Also, if we corrected geometric correction using 16 GCP(Ground Control Point)s, the results of RMSE became $X={\pm}0.104m$, $Y={\pm}0.171m$, $Z={\pm}0.036m$, and t he RMSE of check points were $X={\pm}0.357m$, $Y={\pm}0.239m$, $Z={\pm}0.188m$; which of those results indicated the accuracy of standard adjustment complied in error tolerances of the 1/5,000 scale. Additionally, we converted coordinates of points, obtained by TerraSAR. for comparing with measurements from GPS(Global Positioning System) surveying. The RMSE of comparing converted and GPS points were $X={\pm}0.818m$, $Y={\pm}0.200m$, $Z={\pm}0.265m$, which confirmed the possibility for 1/5,000 digital topographic mapping with PLEIADES images and GCPs. As method of obtaining GCPs in unaccessible area, however, the outcome evaluation of GCPs extracted from TerraSAR images was not acceptable for 1/5,000 digital topographic mapping. Therefore, we considered that further researches are needed on applicability of GCPs extracted from TerraSAR images for future alternative method.

Mathematical Transformation Influencing Accuracy of Near Infrared Spectroscopy (NIRS) Calibrations for the Prediction of Chemical Composition and Fermentation Parameters in Corn Silage (수 처리 방법이 근적외선분광법을 이용한 옥수수 사일리지의 화학적 조성분 및 발효품질의 예측 정확성에 미치는 영향)

  • Park, Hyung-Soo;Kim, Ji-Hye;Choi, Ki-Choon;Kim, Hyeon-Seop
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • This study was conducted to determine the effect of mathematical transformation on near infrared spectroscopy (NIRS) calibrations for the prediction of chemical composition and fermentation parameters in corn silage. Corn silage samples (n=407) were collected from cattle farms and feed companies in Korea between 2014 and 2015. Samples of silage were scanned at 1 nm intervals over the wavelength range of 680~2,500 nm. The optical data were recorded as log 1/Reflectance (log 1/R) and scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares (PLS) multivariate analysis in conjunction with several spectral math treatments to reduce the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation ($R^2{_{cv}}$) and the lowest standard error of cross validation (SECV). Results of this study revealed that the NIRS method could be used to predict chemical constituents accurately (correlation coefficient of cross validation, $R^2{_{cv}}$, ranging from 0.77 to 0.91). The best mathematical treatment for moisture and crude protein (CP) was first-order derivatives (1, 16, 16, and 1, 4, 4), whereas the best mathematical treatment for neutral detergent fiber (NDF) and acid detergent fiber (ADF) was 2, 16, 16. The calibration models for fermentation parameters had lower predictive accuracy than chemical constituents. However, pH and lactic acids were predicted with considerable accuracy ($R^2{_{cv}}$ 0.74 to 0.77). The best mathematical treatment for them was 1, 8, 8 and 2, 16, 16, respectively. Results of this experiment demonstrate that it is possible to use NIRS method to predict the chemical composition and fermentation quality of fresh corn silages as a routine analysis method for feeding value evaluation to give advice to farmers.

Evaluation of the Quality of Simmered Chicken in Soy Sauce Prepared with the Sous vide Cook-Chill System and Conventional Cook-Chill System (Sous vide Cook-Chill System과 Conventional Cook-Chill System으로 생산된 닭고기 장조림의 품질평가)

  • Oh, Kyung-Sook;Ko, Sung-Hee;Kim, Heh-Young
    • Korean journal of food and cookery science
    • /
    • v.22 no.5 s.95
    • /
    • pp.617-625
    • /
    • 2006
  • This study was done to provide basic data for the operation of a safer cook-chill system by comparing and evaluating the quality of foods which were prepared using the sous vide cook-chill system and the conventional cook-chill system, according to the preparation methods and storage temperature. Simmered chickens in soy sauce were prepared using the sous vide cook-chill system and the conventional cook-chill system and their quality was evaluated at the time of preparation and storage. Firstly, foods were prepared using the sous vide cook-chill (SVCC) system and the conventional cook-chill (CC) system and the redquired time and temperature during each preparation stage were measured and physicochemical (pH, Aw, and moisture content) and microbial qualities were evaluated. Secondly, in order to evaluate the quality and safety, the moisture content and microbial (standard plate count, coliform count, psychrotrophic bacteria count, and anaerobic bacteria count) qualities were evaluated according to the preparation methods and temperatures after the foods were stored at 3$^{\circ}C$ and 10$^{\circ}C$ for 10 days and reheated.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.